Development of low-noise high-speed analog ASIC for X-ray CCD cameras and wide-band X-ray imaging sensors

被引:2
作者
Nakajima, Hiroshi [1 ,2 ]
Hirose, Shin-nosuke [1 ,2 ]
Imatani, Ritsuko [1 ,2 ]
Nagino, Ryo [1 ,2 ]
Anabuki, Naohisa [1 ,2 ]
Hayashida, Kiyoshi [1 ,2 ]
Tsunemi, Hiroshi [1 ,2 ]
Doty, John P. [3 ]
Ikeda, Hirokazu [4 ]
Kitamura, Hisashi [5 ]
Uchihori, Yukio [5 ]
机构
[1] Osaka Univ, Grad Sch Sci, Dept Earth & Space Sci, 1-1 Machikaneyama, Toyonaka, Osaka 5600043, Japan
[2] Osaka Univ, Grad Sch Sci, Project Res Ctr Fundamental Sci, 1-1 Machikaneyama, Toyonaka, Osaka 5600043, Japan
[3] Noqsi Aerosp Ltd, 2822 South Nova Rd, Pine, CO 80470 USA
[4] Japan Aerosp Explorat Agcy, Inst Space & Astronaut Sci, Chuo Ku, 3-1-1 Yoshinodai, Sagamihara, Kanagawa 2525210, Japan
[5] Natl Inst Radiol Sci, Inage Ku, Anagawa 4-9-1, Chiba, Chiba 2638555, Japan
关键词
X-ray; ASIC; CCD camera; PERFORMANCE;
D O I
10.1016/j.nima.2016.04.040
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report on the development and performance evaluation of the mixed-signal Application Specific Integrated Circuit (ASIC) developed for the signal processing of onboard X-ray CCD cameras and various types of X-ray imaging sensors in astrophysics. The quick and low-noise readout is essential for the pileup free imaging spectroscopy with a future X-ray telescope. Our goal is the readout noise of 5e r.m.s. at the pixel rate of 1 Mpix/s that is about 10 times faster than those of the currently working detectors. We successfully developed a low-noise ASIC as the front-end electronics of the Soft X-ray Imager onboard Hitomi that was launched on February 17, 2016. However, it has two analog -to -digital converters per chain due to the limited processing speed and hence we need to correct the difference of gain to obtain the X-ray spectra. Furthermore, its input equivalent noise performance is not satisfactory ( > 100 V) at the pixel rate higher than 500 kpix/s. Then we upgrade the design of the ASIC with the fourth-order Az modulators to enhance its inherent noise -shaping performance. Its performance is measured using pseudo CCD signals with variable processing speed. Although its input equivalent noise is comparable with the conventional one, the integrated non -linearity (0.1%) improves to about the half of that of the conventional one. The radiation tolerance is also measured with regard to the total ionizing dose effect and the single event latch -up using protons and Xenon, respectively. The former experiment shows that all of the performances does not change after imposing the dose corresponding to 590 years in a low earth orbit. We also put the upper limit on the frequency of the latch -up to be once per 48 years. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:283 / 287
页数:5
相关论文
共 16 条
  • [1] Bourdopoulos G.I., 2003, DELTA SIGMA MODULATO, DOI DOI 10.1142/P296
  • [2] Doty J.P., 2007, P SOC PHOTO-OPT INS, V6276
  • [3] Inose H., 1962, Space Electronics and Telemetry, IRE Transactions on SET, V8, P204, DOI DOI 10.1109/IRET-SET.1962.5008839
  • [4] Jansen F. A., 2000, B AM ASTRONOMICAL SO, V32, P724
  • [5] Development of an ASIC employing delta-sigma digitization for readout of X-ray CCDs
    Matsuura, D.
    Nakajima, H.
    Miyata, E.
    Tsunemi, H.
    Doty, J. P.
    Ikeda, H.
    [J]. UV, X-RAY, AND GAMMA-RAY SPACE INSTRUMENTATION FOR ASTRONOMY XV, 2007, 6686
  • [6] The X-ray observatory Suzaku
    Mitsuda, Kazuhisa
    Bautz, Mark
    Inoue, Hajime
    Kelley, Richard L.
    Koyama, Katsuji
    Kunieda, Hideyo
    Makshima, Kazuo
    Ogawara, Yoshiaki
    Petre, Robert
    Takahashi, Tadayuki
    Tsunemi, Hiroshi
    White, Nicholas E.
    Anabuki, Naohisa
    Angelini, Lorella
    Arnaud, Keith
    Awaki, Hisamitsu
    Bamba, Aya
    Boyce, Kevin
    Brown, Gregory V.
    Chan, Kai-Wing
    Cottam, Jean
    Dotanli, Tadayasu
    Doty, John
    Ebisawa, Ken
    Ezoe, Yuichiro
    Fabian, Andrew C.
    Figueroa, Enectali
    Fujimoto, Ryuichi
    Fukazawa, Yasushi
    Furusho, Tae
    Furuzawa, Akihiro
    Gendreau, Keith
    Griffiths, Richard E.
    Haba, Yoshito
    Hamaguchi, Kenji
    Harrus, Ilana
    Hasinger, Gunther
    Hatsukade, Isamu
    Hayashida, Kiyoshi
    Henry, Patrick J.
    Hiraga, Junko S.
    Holt, Stephen S.
    Hornschemeier, Ann
    Hughes, John P.
    Hwang, Una
    Ishida, Manabu
    Ishisaki, Yoshitaka
    Isobe, Naoki
    Itoh, Masayuki
    Iyomoto, Naoko
    [J]. PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 2007, 59 : S1 - S7
  • [7] Nakajima H., 2015, JAXARR14007 JAXARR14007, P166
  • [8] Single event effect characterization of the mixed-signal ASIC developed for CCD camera in space use
    Nakajima, Hiroshi
    Fujikawa, Mari
    Mori, Hideki
    Kan, Hiroaki
    Ueda, Shutaro
    Kosugi, Hiroko
    Anabuki, Naohisa
    Hayashida, Kiyoshi
    Tsunemi, Hiroshi
    Doty, John P.
    Ikeda, Hirokazu
    Kitamura, Hisashi
    Uchihori, Yukio
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 731 : 166 - 171
  • [9] Nakajima H, 2011, NUCL INSTRUM METH A, V632, P128, DOI 10.1016/j.nima.2010.12.174
  • [10] Development of X-ray CCD camera system with high readout rate using ASIC
    Nakajima, Hiroshi
    Matsuura, Daisuke
    Anabuki, Naohisa
    Miyata, Emi
    Tsunemi, Hiroshi
    Doty, John P.
    Ikeda, Hirokazu
    Katayama, Haruyoshi
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (01) : 78 - 82