Flow Test to Predict Early Hypotony and Hypertensive Phase After Ahmed Glaucoma Valve (AGV) Surgical Implantation

被引:10
|
作者
Cheng, Jason [1 ]
Beltran-Agullo, Laura [2 ]
Buys, Yvonne M. [3 ]
Moss, Edward B. [3 ]
Gonzalez, Johanna [3 ]
Trope, Graham E. [3 ]
机构
[1] Khoo Tech Puat Hosp, Singapore, Singapore
[2] Inst Catala Retina, Barcelona, Spain
[3] Univ Toronto, Dept Ophthalmol & Vis Sci, Toronto Western Hosp, Toronto, ON, Canada
关键词
Ahmed glaucoma valve; glaucoma; surgery; hypotony; hypertensive phase; CLINICAL-EXPERIENCE; DRAINAGE DEVICES; CLOSING PRESSURE; MOLTENO IMPLANT; SINGLE-PLATE; IN-VITRO; BAERVELDT; POLYPROPYLENE; OUTCOMES;
D O I
10.1097/IJG.0000000000000318
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the validity of a preimplantation flow test to predict early hypotony [intraocular pressure (IOP) <= 5mm Hg on 2 consecutive visits and hypertensive phase (HP) (IOP > 21 mm Hg) after Ahmed Glaucoma Valve (AGV) implantation. Patients and Methods: Prospective interventional study on patients receiving an AGV. A preimplantation flow test using a gravity-driven reservoir and an open manometer was performed on all AGVs. Opening pressure (OP) and closing pressure (CP) were defined as the pressure at which fluid was seen to flow or stop flowing through the AGV, respectively. OP and CP were measured twice per AGV. Patients were followed for 12 weeks. Results: In total, 20 eyes from 19 patients were enrolled. At 12 weeks the mean IOP decreased from 29.2 +/- 9.1 to 16.8 +/- 5.2 mm Hg (P < 0.01). The mean AGV OP was 17.5 +/- 5.4 mm Hg and the mean CP was 6.7 +/- 2.3 mm Hg. Early (within 2 wk postoperative) HP occurred in 37% and hypotony in 16% of cases. An 18 mm Hg cutoff for the OP gave a sensitivity of 0.71, specificity of 0.83, positive predictive value of 0.71, and negative predictive value of 0.83 for predicting an early HP. A 7 mm Hg cutoff for the CP yielded a sensitivity of 1.0, specificity of 0.38, positive predictive value of 0.23, and negative predictive value of 1.0 for predicting hypotony. Conclusions: Preoperative OP and CP may predict early hypotony or HP and may be used as a guide as to which AGV valves to discard before implantation surgery.
引用
收藏
页码:493 / 496
页数:4
相关论文
共 50 条
  • [31] Postoperative Blepharoptosis after Trabeculectomy versus Ahmed Glaucoma Valve Implantation
    Nilforushan, Naveed
    Es'haghi, Acieh
    Jafari, Samira
    Abdolalizadeh, Parya
    Miraftabi, Arezoo
    Chaibakhsh, Samira
    Kashkouli, Mohsen Bahmani
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2021, 33 (04): : 388 - 393
  • [32] Intraocular pressure control after the implantation of a second Ahmed glaucoma valve
    Jesús Jiménez-Román
    Félix Gil-Carrasco
    Vital Paulino Costa
    Rui Barroso Schimiti
    Fabián Lerner
    Priscila Rezende Santana
    Jose Paulo Cabral Vascocellos
    Armando Castillejos-Chévez
    Mauricio Turati
    Karina Fabre-Miranda
    International Ophthalmology, 2016, 36 : 347 - 353
  • [33] A Novel Surgical Technique for Ahmed Glaucoma Valve Implantation Without Plate Sutures
    Sanvicente, Carina T.
    Moster, Marlene R.
    Lee, Daniel
    Menezes, Alicia
    Ghahramani, Aria
    Zhang, Qiang
    Hamershock, Rose
    Myers, Jonathan S.
    JOURNAL OF GLAUCOMA, 2020, 29 (03) : 161 - 167
  • [34] Non-intraocular pressure-related revision surgeries after Ahmed glaucoma valve (AGV) implantation in refractory glaucoma
    Asli Kirmaci Kabakci
    Banu Solmaz
    Berna Basarir
    Burcu Kemer Atik
    Tekin Yasar
    International Ophthalmology, 2021, 41 : 3533 - 3538
  • [35] Long-Term Visual Field Outcomes After Ahmed Glaucoma Valve Implantation
    Khaliliyeh, Daniela
    De Gainza, Agustina
    Morales, Esteban
    Caprioli, Joseph
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 251 : 173 - 188
  • [36] Non-intraocular pressure-related revision surgeries after Ahmed glaucoma valve (AGV) implantation in refractory glaucoma
    Kabakci, Asli Kirmaci
    Solmaz, Banu
    Basarir, Berna
    Atik, Burcu Kemer
    Yasar, Tekin
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (10) : 3533 - 3538
  • [37] Initial Glaucoma Medication in the Hypertensive Phase Following Ahmed Valve Implantation: A Comparison of Results Achieved Using Aqueous Suppressants and Prostaglandin Analogs
    Lee, Jiyun
    Park, Chan Kee
    Jung, Kyoung In
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (02)
  • [38] Two Cases of Malignant Glaucoma after Ahmed Valve Implantation
    Kim, Jae Hyun
    Chey, Ji Hyoung
    Lee, Chang Kyu
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (06): : 566 - 570
  • [39] Ocular biometric changes after Ahmed glaucoma valve implantation
    Miraftabi, Arezoo
    Lotfi, Mahboubeh
    Nilforushan, Naveed
    Abdolalizadeh, Parya
    Jafari, Samira
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (01) : 120 - 124
  • [40] Visual prognosis and surgical timing of Ahmed glaucoma valve implantation for neovascular glaucoma secondary to diabetic vitrectomy
    Lee, Jong Suk
    Lee, Young Bok
    Kim, Tae-Woo
    Park, Kyu Hyung
    BMC OPHTHALMOLOGY, 2023, 23 (01)