Effect of Soiling on Power Output of a Photovoltaic System

被引:7
作者
Goel, Sonali [1 ]
Panda, Sobhit [2 ]
Kumar, Nallapaneni Manoj [3 ]
Sharma, Renu [1 ]
机构
[1] SOA Deemed Univ, Dept Elect Engn, Bhubaneswar 751030, Odisha, India
[2] CET, Instrumentat & Elect Engn, Bhubaneswar 751003, India
[3] City Univ Hong Kong, Sch Energy & Environm, Kowloon, Hong Kong, Peoples R China
来源
INNOVATION IN ELECTRICAL POWER ENGINEERING, COMMUNICATION, AND COMPUTING TECHNOLOGY, IEPCCT 2019 | 2020年 / 630卷
关键词
Solar photovoltaic; Losses; Performance; PERFORMANCE; DUST;
D O I
10.1007/978-981-15-2305-2_28
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The power output of a photovoltaic (PV) module depends on the geographical locations (latitude, longitude and solar irradiance), tilt angle and its climatic condition (humidity, temperature) and shading due to soiling, bird droppings, etc. This paper deals with the power loss in solar PV system due to deposit of dust particles on the PV surface. The loss of power due to soiling was studied for a rooftop solar PV system installed in SOA (Deemed to be University), Bhubaneswar, India. It was observed that power loss to an extent of 3.09% per day occurred during non-monsoon months, while it reduced to 0.93% per day during monsoon months due to accumulation of soil on PV modules.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 17 条
  • [1] Baltus C. W. A., 1997, P 14 EUR PHOT SOL EN
  • [2] Denholm P, 2010, GENERATING ELECTRICITY IN A CARBON-CONSTRAINED WORLD, P271, DOI 10.1016/B978-1-85617-655-2.00010-9
  • [3] El-Shobokshy M. S., 1993, Renewable Energy, V3, P585, DOI 10.1016/0960-1481(93)90064-N
  • [4] EFFECT OF DUST WITH DIFFERENT PHYSICAL-PROPERTIES ON THE PERFORMANCE OF PHOTOVOLTAIC CELLS
    ELSHOBOKSHY, MS
    HUSSEIN, FM
    [J]. SOLAR ENERGY, 1993, 51 (06) : 505 - 511
  • [5] A new model to predict the energy generated by a photovoltaic system connected to the grid in low latitude countries
    Fernando Mulcue-Nieto, Luis
    Mora-Lopez, Llanos
    [J]. SOLAR ENERGY, 2014, 107 : 423 - 442
  • [6] Hottel H., 1942, Trans. ASME (Am. Soc. Mech. Eng.), V64
  • [7] Kimber A, 2006, WORL CON PHOTOVOLT E, P2391
  • [8] Power loss due to soiling on solar panel: A review
    Maghami, Mohammad Reza
    Hizam, Hashim
    Gomes, Chandima
    Radzi, Mohd Amran
    Rezadad, Mohammad Ismael
    Hajighorbani, Shahrooz
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 59 : 1307 - 1316
  • [9] Impact of dust on solar photovoltaic (PV) performance: Research status, challenges and recommendations
    Mani, Monto
    Pillai, Rohit
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (09) : 3124 - 3131
  • [10] Comparison of measured and predicted long term performance of grid a connected photovoltaic system
    Mondol, Jayanta Deb
    Yohanis, Yigzaw G.
    Norton, Brian
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (04) : 1065 - 1080