Comparison of six regression-based lot-to-lot verification approaches

被引:7
作者
Koh, Norman Wen Xuan [1 ]
Markus, Corey [2 ]
Loh, Tze Ping [3 ]
Lim, Chun Yee [1 ]
机构
[1] Singapore Inst Technol, Engn Cluster, Singapore, Singapore
[2] Prince Wales Hosp, Dept Chem Pathol, New South Wales Hlth Pathol, Sydney, NSW, Australia
[3] Natl Univ Singapore Hosp, Dept Lab Med, 5 Lower Kent Ridge Rd, Singapore 119074, Singapore
关键词
between-reagent lot; bias; drift; reagent lot; shift; POWER;
D O I
10.1515/cclm-2022-0274
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives Detection of between-lot reagent bias is clinically important and can be assessed by application of regression-based statistics on several paired measurements obtained from the existing and new candidate lot. Here, the bias detection capability of six regression-based lot-to-lot reagent verification assessments, including an extension of the Bland-Altman with regression approach are compared. Methods Least squares and Deming regression (in both weighted and unweighted forms), confidence ellipses and Bland-Altman with regression (BA-R) approaches were investigated. The numerical simulation included permutations of the following parameters: differing result range ratios (upper:lower measurement limits), levels of significance (alpha), constant and proportional biases, analytical coefficients of variation (CV), and numbers of replicates and sample sizes. The sample concentrations simulated were drawn from a uniformly distributed concentration range. Results At a low range ratio (1:10, CV 3%), the BA-R performed the best, albeit with a higher false rejection rate and closely followed by weighted regression approaches. At larger range ratios (1:1,000, CV 3%), the BA-R performed poorly and weighted regression approaches performed the best. At higher assay imprecision (CV 10%), all six approaches performed poorly with bias detection rates <50%. A lower alpha reduced the false rejection rate, while greater sample numbers and replicates improved bias detection. Conclusions When performing reagent lot verification, laboratories need to finely balance the false rejection rate (selecting an appropriate alpha) with the power of bias detection (appropriate statistical approach to match assay performance characteristics) and operational considerations (number of clinical samples and replicates, not having alternate reagent lot).
引用
收藏
页码:1175 / 1185
页数:11
相关论文
共 17 条
[1]   Failure of Current Laboratory Protocols to Detect Lot-to-Lot Reagent Differences: Findings and Possible Solutions [J].
Algeciras-Schimnich, Alicia ;
Bruns, David E. ;
Boyd, James C. ;
Bryant, Sandra C. ;
La Fortune, Kristin A. ;
Grebe, Stefan K. G. .
CLINICAL CHEMISTRY, 2013, 59 (08) :1187-1194
[2]   More on Lot-to-Lot Changes [J].
Bais, Renze ;
Chesher, Douglas .
CLINICAL CHEMISTRY, 2014, 60 (02) :413-414
[3]   Failure of internal quality control in detecting significant reagent lot shift in serum creatinine measurement [J].
Chen, Xiaoting ;
Wang, Jia ;
Zhang, Wei ;
Xie, Erfu ;
Zhang, Bingfeng ;
Xu, Hua-Guo .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2019, 33 (09)
[4]  
Clinical and Laboratory Standards Institute, 2008, EP26A CLSI
[5]  
Draper N.R., 1998, Applied Regression Analysis, V3rd ed.
[6]   Understanding Bland Altman analysis [J].
Giavarina, Davide .
BIOCHEMIA MEDICA, 2015, 25 (02) :141-151
[7]   An approach for determining allowable between reagent lot variation [J].
Lantman, Marith van Schrojenstein ;
Cubukcu, Hikmet Can ;
Boursier, Guilaine ;
Panteghini, Mauro ;
Bernabeu-Andreu, Francisco A. ;
Milinkovic, Neda ;
Brguljan, Pika Mesko ;
Linko, Solveig ;
Brugnoni, Duilio ;
O'Kelly, Ruth ;
Kroupis, Christos ;
Lohmander, Maria ;
Sprongl, Ludek ;
Vanstapel, Florent ;
Thelen, Marc .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (05) :681-688
[8]  
Linnet K, 1999, CLIN CHEM, V45, P882
[9]   Detecting Long-term Drift in Reagent Lots [J].
Liu, Jiakai ;
Tan, Chin Hon ;
Loh, Tze Ping ;
Badrick, Tony .
CLINICAL CHEMISTRY, 2015, 61 (10) :1292-1298
[10]   Lot-to-lot reagent verification: challenges and possible solutions [J].
Loh, Tze Ping ;
Sandberg, Sverre ;
Horvath, Andrea Rita .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (05) :675-680