On-off nonlinear active control of floor vibrations

被引:43
作者
Diaz, Ivan M. [1 ,2 ]
Reynolds, Paul [2 ]
机构
[1] Univ Castilla La Mancha, Escuela Tecn Super Ingenieros Ind, E-13071 Ciudad Real, Spain
[2] Univ Sheffield, Dept Civil & Struct Engn, Sheffield S1 3JD, S Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
Active control; Structural control; Floor vibrations; Nonlinear velocity feedback; Human-induced vibrations;
D O I
10.1016/j.ymssp.2010.02.011
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Human-induced floor vibrations can be mitigated by means of active control via an electromagnetic proof-mass actuator. Previous researchers have developed a system for floor vibration comprising linear velocity feedback control (LVFC) with a command limiter (saturation in the command signal to avoid actuator overloading). The performance of this control is highly dependent on the linear gain utilised, which has to be designed for a particular excitation and might not be optimum for other excitations. This work explores the use of on-off nonlinear velocity feedback control (NLVFC) as the natural evolution of LVFC when high gains and/or significant vibration level are present together with saturation in the control law. Firstly, the describing function tool is employed to analyse the stability properties of: (1) LVFC with saturation, (2) on-off NLVFC with a dead zone and (3) on-off NLVFC with a switching-off function. Particular emphasis is paid to the resulting limit cycle behaviour and the design of appropriate dead zone and switching-off levels to avoid it. Secondly, experimental trials using the three control laws are conducted on a laboratory test floor. The results corroborate the analytical stability predictions. The pros of on-off NLVFC are that no gain has to be chosen and maximum actuator energy is delivered to cancel the vibration. In contrast, the requirement to select a dead zone or switching-off function provides a drawback in its application. (c) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1711 / 1726
页数:16
相关论文
共 26 条
[1]  
[Anonymous], SMART MAT STRUCTURES
[2]   CASE-STUDIES OF STRUCTURES WITH MAN-INDUCED VIBRATIONS [J].
BACHMANN, H .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (03) :631-647
[3]  
Bachmann Hugo., 1987, Vibrations in structures: induced by man and machines, V3
[4]  
BALAS MJ, 1979, J GUIDANCE CONTROL, V2, P253
[5]   Robust saturated control of human-induced floor vibrations via a proof-mass actuator [J].
Diaz, I. M. ;
Reynolds, P. .
SMART MATERIALS AND STRUCTURES, 2009, 18 (12)
[6]  
DIAZ IM, P 4 EUR C STRUCT CON, P175
[7]   Mixed H2/H∞ control of tall buildings with reduced-order modelling technique [J].
Du, Haiping ;
Zhang, Nong ;
Nguyen, Hung .
STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (01) :64-89
[8]   A review of vibration serviceability criteria for floor structures [J].
Ebrahimpour, A ;
Sack, RL .
COMPUTERS & STRUCTURES, 2005, 83 (28-30) :2488-2494
[9]  
GAWRONSKI W., 2004, Advanced Structural Dynamics and Active Control of Structures
[10]   Mitigation of seismic responses on building structures using MR dampers with Lyapunov-based control [J].
Ha, Q. P. ;
Kwok, N. M. ;
Nguyen, M. T. ;
Li, J. ;
Samali, B. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (04) :604-621