Accuracy of breath test for diabetes mellitus diagnosis: a systematic review and meta-analysis

被引:18
作者
Wang, Wenting [1 ]
Zhou, Wenzhao [2 ]
Wang, Sheng [3 ]
Huang, Jinyu [1 ]
Le, Yanna [4 ]
Nie, Shijiao [1 ]
Wang, Weijue [5 ]
Guo, Qing [3 ,5 ]
机构
[1] Zhejiang Univ, Affiliated Hangzhou Peoples Hosp 1, Sch Med, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Inst Metrol, Dept Biol & Chem, Hangzhou, Peoples R China
[3] Hangzhou Normal Univ, Dept Med, Hangzhou, Zhejiang, Peoples R China
[4] Hangzhou Med Assoc, Hangzhou, Peoples R China
[5] Zhejiang Chinese Med Univ, Sch Humanities & Management, Hangzhou, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
diabetes mellitus; experimental; diagnostic techniques and procedures; biomarkers; meta-analysis; EXHALED BREATH; POTENTIAL BIOMARKER; ACETONE; FOCUS;
D O I
10.1136/bmjdrc-2021-002174
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The review aimed to investigate the accuracy of breath tests in the diagnosis of diabetes mellitus, identify exhaled volatile organic compounds with the most evidence as potential biomarkers, and summarize prospects and challenges in diabetic breath tests. Databases including Medline, PubMed, EMBASE, Cochrane Library and Science Citation Index Expanded were searched. Human studies describing diabetic breath analysis with more than 10 subjects as controls and patients were included. Population demographics, breath test conditions, biomarkers, analytical techniques and diagnostic accuracy were extracted. Quality assessment was performed with the Standards for Reporting Diagnostic Accuracy and a modified QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2). Forty-four research with 2699 patients with diabetes were included for qualitative data analysis and 14 eligible studies were used for meta-analysis. Pooled analysis of type 2 diabetes breath test exhibited sensitivity of 91.8% (95% CI 83.6% to 96.1%), specificity of 92.1% (95% CI 88.4% to 94.7%) and area under the curve (AUC) of 0.96 (95% CI 0.94 to 0.97). Isotopic carbon dioxide (CO2) showed the best diagnostic accuracy with pooled sensitivity of 0.949 (95% CI 0.870 to 0.981), specificity of 0.946 (95% CI 0.891 to 0.975) and AUC of 0.98 (95% CI 0.97 to 0.99). As the most widely reported biomarker, acetone showed moderate diagnostic accuracy with pooled sensitivity of 0.638 (95% CI 0.511 to 0.748), specificity of 0.801 (95% CI 0.691 to 0.878) and AUC of 0.79 (95% CI 0.75 to 0.82). Our results indicate that breath test is a promising approach with acceptable diagnostic accuracy for diabetes mellitus and isotopic CO2 is the optimal breath biomarker. Even so, further validation and standardization in subject control, breath sampling and analysis are still required.
引用
收藏
页数:10
相关论文
共 30 条
[1]   Applications of breath gas analysis in medicine [J].
Amann, A ;
Poupart, G ;
Telser, S ;
Ledochowski, M ;
Schmid, A ;
Mechtcheriakov, S .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 239 (2-3) :227-233
[2]   Analysis of Exhaled Breath for Disease Detection [J].
Amann, Anton ;
Miekisch, Wolfram ;
Schubert, Jochen ;
Buszewski, Boguslaw ;
Ligor, Tomasz ;
Jezierski, Tadeusz ;
Pleil, Joachim ;
Risby, Terence .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 7, 2014, 7 :455-482
[3]  
Amer Diabet Assoc, 2014, DIABETES CARE, V37, pS81, DOI [10.2337/dc11-S011, 10.2337/dc12-s064, 10.2337/dc13-S067, 10.2337/dc14-S081, 10.2337/dc10-S011, 10.2337/dc12-s011, 10.2337/dc13-S011, 10.2337/dc11-S062, 10.2337/dc10-S062]
[4]  
Briggs AP, 1940, J LAB CLIN MED, V25, P603
[5]   Selective Detection of Acetone and Hydrogen Sulfide for the Diagnosis of Diabetes and Halitosis Using SnO2 Nanofibers Functionalized with Reduced Graphene Oxide Nanosheets [J].
Choi, Seon-Jin ;
Jang, Bong-Hoon ;
Lee, Seo-Jin ;
Min, Byoung Koun ;
Rothschild, Avner ;
Kim, Il-Doo .
ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (04) :2588-2597
[6]   A review of the volatiles from the healthy human body [J].
Costello, B. de Lacy ;
Amann, A. ;
Al-Kateb, H. ;
Flynn, C. ;
Filipiak, W. ;
Khalid, T. ;
Osborne, D. ;
Ratcliffe, N. M. .
JOURNAL OF BREATH RESEARCH, 2014, 8 (01)
[7]   Significance of Exhaled Breath Test in Clinical Diagnosis: A Special Focus on the Detection of Diabetes Mellitus [J].
Das, Souvik ;
Pal, Saurabh ;
Mitra, Madhuchhanda .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2016, 36 (05) :605-624
[8]   Insulin sensitivity index (ISI0, 120) potentially linked to carbon isotopes of breath CO2 for pre-diabetes and type 2 diabetes [J].
Ghosh, Chiranjit ;
Mukhopadhyay, Prabuddha ;
Ghosh, Shibendu ;
Pradhan, Manik .
SCIENTIFIC REPORTS, 2015, 5
[9]   Oxygen-18 isotope of breath CO2 linking to erythrocytes carbonic anhydrase activity: a biomarker for pre-diabetes and type 2 diabetes [J].
Ghosh, Chiranjit ;
Banik, Gourab D. ;
Maity, Abhijit ;
Som, Suman ;
Chakraborty, Arpita ;
Selvan, Chitra ;
Ghosh, Shibendu ;
Chowdhury, Subhankar ;
Pradhan, Manik .
SCIENTIFIC REPORTS, 2015, 5
[10]   Influence of carbonic anhydrase activity in terrestrial vegetation on the 18O content of atmospheric CO2 [J].
Gillon, J ;
Yakir, D .
SCIENCE, 2001, 291 (5513) :2584-2587