A reagentless biosensor of nitric oxide based on direct electron transfer process of cytochrome C on multi-walled carbon nanotube

被引:13
|
作者
Zhao, GC [1 ]
Yin, ZZ [1 ]
Wei, XW [1 ]
机构
[1] Anhui Normal Univ, Sch Chem & Mat Sci, Anhui Key Lab Funct Mol Solids, Wuhu 241000, Peoples R China
来源
FRONTIERS IN BIOSCIENCE-LANDMARK | 2005年 / 10卷
关键词
cytochrome c; multi-walled carbon nanotube; direct electron- transfer; biosensor;
D O I
10.2741/1675
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Direct electron transfer between Cytochrome c (Cyt.c) and electrode can be achieved through immobilizing Cyt.c on the surface of multi-walled carbon nanotubes (MWNTs). Under the condition of cyclic potential scans, Cyt.c can be adsorbed on the surface of MWNTs that were modified on a glassy carbon (GC) electrode to form an approximate monolayer. The redox characteristic and bioactivity of Cyt.c could be remained after it was adsorbed on MWNTs' surface. This provides a way to construct a new biosenser based on the activity of Cyt.c. Further investigation displayed that Cyt.c adsorbed on MWNTs showed an enzyme-like activity to catalyze the reduction of nitric oxide (NO). Due to catalyzing by Cyt.c, the reduction of NO in aqueous solution was achieved, which reductive potential appeared at -0.747V (vs. SCE). The peak currents were linearly proportional to concentration of NO in the range from 2 to 48 mu mol/l with a limit of detection of 1.3 mu M. The biosensor showed a good stability and excellent repeatability.
引用
收藏
页码:2005 / 2010
页数:6
相关论文
共 50 条
  • [1] Functionalization of multi-walled carbon nanotube for electrocatalytic oxidation of nitric oxide
    Kan, Kan
    Xia, Tingliang
    Yang, Ying
    Bi, Hongmei
    Fu, Honggang
    Shi, Keying
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (03) : 593 - 599
  • [2] A nitric oxide biosensor based on myoglobin adsorbed on multi-walled carbon nanotubes
    Zhang, L
    Zhao, GC
    Wei, XW
    Yang, ZS
    ELECTROANALYSIS, 2005, 17 (07) : 630 - 634
  • [3] Direct electrochemistry of cytochrome c and biosensing for hydrogen peroxide on polyaniline grafted multi-walled carbon nanotube electrode
    Lee, Kwang-Pill
    Gopalan, Anantha Iyengar
    Komathi, Shanmugasundaram
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (02) : 518 - 525
  • [4] Direct electrochemistry of cytochrome c immobilized on titanium nitride/multi-walled carbon nanotube composite for amperometric nitrite biosensor
    Haldorai, Yuvaraj
    Hwang, Seung-Kyu
    Gopalan, Anantha-Iyengar
    Huh, Yun Suk
    Han, Young-Kyu
    Voit, Walter
    Sai-Anand, Gopalan
    Lee, Kwang-Pill
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 543 - 552
  • [5] Immobilization, characterization and direct electron transfer reaction of ferredoxin on multi-walled carbon nanotube
    Lu Ya-Fen
    Cai Chen-Xin
    ACTA CHIMICA SINICA, 2006, 64 (24) : 2396 - 2402
  • [6] Functionalization of multi-walled carbon nanotube for electrocatalytic oxidation of nitric oxide
    Kan Kan
    Tingliang Xia
    Ying Yang
    Hongmei Bi
    Honggang Fu
    Keying Shi
    Journal of Applied Electrochemistry, 2010, 40 : 593 - 599
  • [7] Non-covalent functionalization of multi-walled carbon nanotubes with cytochrome c: Enhanced direct electron transfer and analytical applications
    Eguilaz, Marcos
    Gutierrez, Alejandro
    Rivas, Gustavo
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 225 : 74 - 80
  • [8] A novel multi-walled carbon nanotube-based biosensor for glucose detection
    Wang, SG
    Zhang, Q
    Wang, RL
    Yoon, SF
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2003, 311 (03) : 572 - 576
  • [9] Promoting of direct electron transfer of multicopper oxidase by control of enzyme molecule density on multi-walled carbon nanotube
    Takamura, Eiichiro
    Ohnishi, Taku
    Sakamoto, Hiroaki
    Satomura, Takenori
    Suye, Shin-ichiro
    JOURNAL OF PHYSICS-ENERGY, 2021, 3 (01):
  • [10] Direct electron transfer between glucose oxidase and multi-walled carbon nanotubes
    Xu, JZ
    Zhu, JJ
    Wu, Q
    Hu, Z
    Chen, HY
    CHINESE JOURNAL OF CHEMISTRY, 2003, 21 (08) : 1088 - 1091