Assessing genetic polymorphisms using DNA extracted from cells present in saliva samples

被引:22
|
作者
Nemoda, Zsofia [1 ]
Horvat-Gordon, Maria [2 ]
Fortunato, Christine K. [3 ]
Beltzer, Emilie K. [3 ]
Scholl, Jessica L. [2 ]
Granger, Douglas A. [4 ,5 ]
机构
[1] Semmelweis Univ, Dept Med Chem Mol Biol & Pathobiochem, Budapest, Hungary
[2] Salimetrics LLC, State Coll, PA USA
[3] Penn State Univ, Dept Human Dev & Family Studies & Biobehav Hlth, University Pk, PA 16802 USA
[4] Johns Hopkins Univ, Sch Nursing, Ctr Interdisciplinary Salivary Biosci Res, Baltimore, MD USA
[5] Bloomberg Sch Publ Hlth, Baltimore, MD USA
来源
关键词
ALPHA-AMYLASE; COLLECTION; ASSOCIATION; STABILITY; CORTISOL; TESTOSTERONE; DISORDERS; SEROTONIN; IMMUNOASSAY; STRESS;
D O I
10.1186/1471-2288-11-170
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Technical advances following the Human Genome Project revealed that high-quality and -quantity DNA may be obtained from whole saliva samples. However, usability of previously collected samples and the effects of environmental conditions on the samples during collection have not been assessed in detail. In five studies we document the effects of sample volume, handling and storage conditions, type of collection device, and oral sampling location, on quantity, quality, and genetic assessment of DNA extracted from cells present in saliva. Methods: Saliva samples were collected from ten adults in each study. Saliva volumes from .10-1.0 ml, different saliva collection devices, sampling locations in the mouth, room temperature storage, and multiple freeze-thaw cycles were tested. One representative single nucleotide polymorphism (SNP) in the catechol-0-methyltransferase gene (COMT rs4680) and one representative variable number of tandem repeats (VNTR) in the serotonin transporter gene (5-HTTLPR: serotonin transporter linked polymorphic region) were selected for genetic analyses. Results: The smallest tested whole saliva volume of .10 ml yielded, on average, 1.43 +/- .77 mu g DNA and gave accurate genotype calls in both genetic analyses. The usage of collection devices reduced the amount of DNA extracted from the saliva filtrates compared to the whole saliva sample, as 54-92% of the DNA was retained on the device. An "adhered cell" extraction enabled recovery of this DNA and provided good quality and quantity DNA. The DNA from both the saliva filtrates and the adhered cell recovery provided accurate genotype calls. The effects of storage at room temperature (up to 5 days), repeated freeze-thaw cycles (up to 6 cycles), and oral sampling location on DNA extraction and on genetic analysis from saliva were negligible. Conclusions: Whole saliva samples with volumes of at least .10 ml were sufficient to extract good quality and quantity DNA. Using 10 ng of DNA per genotyping reaction, the obtained samples can be used for more than one hundred candidate gene assays. When saliva is collected with an absorbent device, most of the nucleic acid content remains in the device, therefore it is advisable to collect the device separately for later genetic analyses.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Assessing genetic polymorphisms using DNA extracted from cells present in saliva samples
    Zsofia Nemoda
    Maria Horvat-Gordon
    Christine K Fortunato
    Emilie K Beltzer
    Jessica L Scholl
    Douglas A Granger
    BMC Medical Research Methodology, 11
  • [2] Feasibility Study of HEA BeadChip Genotyping With DNA Extracted from Saliva Samples
    Sodowich, B. I.
    Patel, J.
    Enriquez, E.
    Ishtiaq, G.
    Naik, U.
    Garg, D.
    TRANSFUSION, 2013, 53 : 161A - 162A
  • [3] ALLOSEQ TX GENOTYPING USING DNA EXTRACTED FROM SALIVA
    Kolanski, Supaneda N.
    Dallas, Peter B.
    Hogan, Hayley M.
    Etcell, Jessica A.
    Newbound, Christopher N.
    Goodridge, Damian M.
    Saye, David C.
    HLA, 2020, 95 (04) : 405 - 405
  • [4] HLA TYPING WITH QTYPE® USING DNA EXTRACTED FROM SALIVA
    Xu, Connie
    Kmiec, Beata
    Passey, Ben
    Hedlund, Anna
    Sayer, David C.
    HLA, 2020, 95 (04) : 403 - 404
  • [5] Quality of DNA extracted from saliva samples collected with the Oragene™ DNA self-collection kit
    Nunes, Ana P.
    Oliveira, Isabel O.
    Santos, Betnia R.
    Millech, Cristini
    Silva, Liziane P.
    Gonzalez, David A.
    Hallal, Pedro C.
    Menezes, Ana M. B.
    Araujo, Cora L.
    Barros, Fernando C.
    BMC MEDICAL RESEARCH METHODOLOGY, 2012, 12
  • [6] Quality of DNA extracted from saliva samples collected with the Oragene™ DNA self-collection kit
    Ana P Nunes
    Isabel O Oliveira
    Betânia R Santos
    Cristini Millech
    Liziane P Silva
    David A González
    Pedro C Hallal
    Ana M B Menezes
    Cora L Araújo
    Fernando C Barros
    BMC Medical Research Methodology, 12
  • [7] Comparison of DNA Extracted from Pediatric Saliva, Gingival Crevicular Fluid and Site-Specific Biofilm Samples
    Emett, Jason
    David, Roxanne
    McDaniel, Jaydene
    McDaniel, Steven
    Kingsley, Karl
    METHODS AND PROTOCOLS, 2020, 3 (03) : 1 - 10
  • [8] Quantity and Quality Assessment of DNA Extracted from Saliva and Blood
    Looi, Mee-Lee
    Zakaria, Hasbullani
    Osman, Junaida
    Jamal, Rahman
    CLINICAL LABORATORY, 2012, 58 (3-4) : 307 - 312
  • [9] Age Estimation Using DNA Extracted from Human Saliva as a Diagnostic Measure in Forensic Odontology
    Keerthana, T.
    Ramesh, Sindhu
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (02): : 132 - 139
  • [10] The Utility of DNA Extracted from Saliva for Methylation Studies of Psychiatric Traits
    Smith, Alicia K.
    Kilaru, Varun
    Klengel, Torsten
    Mercer, Kristina B.
    Conneely, Karen
    Ressler, Kerry J.
    Binder, Elisabeth
    NEUROPSYCHOPHARMACOLOGY, 2013, 38 : S488 - S489