Terahertz-Based Porosity Measurement of Pharmaceutical Tablets: a Tutorial

被引:65
作者
Bawuah, Prince [1 ]
Markl, Daniel [2 ,3 ]
Farrell, Daniel [4 ]
Evans, Mike [4 ]
Portieri, Alessia [4 ]
Anderson, Andrew [5 ]
Goodwin, Daniel [5 ]
Lucas, Ralph [6 ]
Zeitler, J. Axel [1 ]
机构
[1] Univ Cambridge, Dept Chem Engn & Biotechnol, Philippa Fawcett Dr, Cambridge CB3 0AS, England
[2] Univ Strathclyde, Strathclyde Inst Pharm & Biomed Sci, Glasgow, Lanark, Scotland
[3] Univ Strathclyde, Technol & Innovat Ctr, EPSRC Future Mfg Res Hub Continuous Mfg & Adv Cry, Glasgow, Lanark, Scotland
[4] TeraView Ltd 1, Cambridge Res Pk, Enterprise, Cambridge CB25 9PD, England
[5] GSK, David Jack Ctr Res & Dev, Pk Rd, Ware, Herts, England
[6] Huxley Bertram Engn Ltd, 53 Pembroke Ave, Cambridge, England
基金
英国工程与自然科学研究理事会;
关键词
Terahertz spectroscopy; Pharmaceutical tablet; Porosity; Effective medium approximation; Refractive index; Optical path length; TIME-DOMAIN SPECTROSCOPY; PULSED SPECTROSCOPY; PORE STRUCTURE; VIBRATIONAL-SPECTRA; PHASE-TRANSITIONS; COATING THICKNESS; CRYSTALLIZATION; TRANSMISSION; POLYMORPHS; CONSTANTS;
D O I
10.1007/s10762-019-00659-0
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Porosity, one of the important quality attributes of pharmaceutical tablets, directly affects the mechanical properties, the mass transport and hence tablet disintegration, dissolution and ultimately the bioavailability of an orally administered drug. The ability to accurately and quickly monitor the porosity of tablets during manufacture or during the manufacturing process will enable a greater assurance of product quality. This tutorial systematically outlines the steps involved in the terahertz-based measurement method that can be used to quantify the porosity of a tablet within seconds in a non-destructive and non-invasive manner. The terahertz-based porosity measurement can be performed using one of the three main methods, which are (i) the zero-porosity approximation (ZPA); (ii) the traditional Bruggeman effective medium approximation (TB-EMA); and (iii) the anisotropic Bruggeman effective medium approximation (AB-EMA). By using a set of batches of flat-faced and biconvex tablets as a case study, the three main methods are compared and contrasted. Overall, frequency-domain signal processing coupled with the AB-EMA method was found to be most suitable approach in terms of accuracy and robustness when predicting the porosity of tablets over a range of complexities and geometries. This tutorial aims to concisely outline all the necessary steps, precautions and unique advantages associated with the terahertz-based porosity measurement method.
引用
收藏
页码:450 / 469
页数:20
相关论文
共 62 条
[1]   Terahertz absorption spectra of commonly used antimalarial drugs [J].
Bawuah, Prince ;
Zeitler, J. Axel ;
Ketolainen, Jarkko ;
Peiponen, Kai-Erik .
OPTICAL REVIEW, 2018, 25 (03) :444-449
[2]   Terahertz study on porosity and mass fraction of active pharmaceutical ingredient of pharmaceutical tablets [J].
Bawuah, Prince ;
Tan, Nicholas ;
Tweneboah, Samuel Nana A. ;
Ervasti, Tuomas ;
Zeitler, J. Axel ;
Ketolainen, Jarkko ;
Peiponen, Kai-Erik .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2016, 105 :122-133
[3]   Noninvasive porosity measurement of biconvex tablets using terahertz pulses [J].
Bawuah, Prince ;
Ervasti, Tuomas ;
Tan, Nicholas ;
Zeitler, J. Axel ;
Ketolainen, Jarkko ;
Peiponen, Kai-Erik .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2016, 509 (1-2) :439-443
[4]   Non-contact weight measurement of flat-faced pharmaceutical tablets using terahertz transmission pulse delay measurements [J].
Bawuah, Prince ;
Silfsten, Pertti ;
Ervasti, Tuomas ;
Ketolainen, Jarkko ;
Zeitler, J. Axel ;
Peiponen, Kai-Erik .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 476 (1-2) :16-22
[5]   Detection of porosity of pharmaceutical compacts by terahertz radiation transmission and light reflection measurement techniques [J].
Bawuah, Prince ;
Mendia, Alessandra Pierotic ;
Silfsten, Pertti ;
Paakkonen, Pertti ;
Ervasti, Tuomas ;
Ketolainen, Jarkko ;
Zeitler, J. Axel ;
Peiponen, Kai-Erik .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 465 (1-2) :70-76
[6]   Optical Constants of Harmful and Highly Energetic Liquids for Application to THz Screening Systems [J].
Beckmann, Joerg ;
Marchetti, Barbara ;
von Chrzanowski, Lars S. ;
Ritter, Eglof ;
Puskar, Ljiljana ;
Aziz, Emad F. ;
Schade, Ulrich .
IEEE TRANSACTIONS ON TERAHERTZ SCIENCE AND TECHNOLOGY, 2016, 6 (03) :396-407
[8]   Paper Parameter Estimation Using Terahertz Time-Domain Spectroscopy [J].
Dodge, J. Steven ;
Mousavi, Payam ;
Bushfield, Ian ;
Savard, Stephane ;
Jez, David ;
Haran, Frank .
PROCEEDINGS OF 2014 INTERNATIONAL SYMPOSIUM ON OPTOMECHATRONIC TECHNOLOGIES (ISOT), 2014, :119-120
[9]  
Dong Y., 2014, 40 INT C INFR MILL T, P2015
[10]   Material parameter estimation with terahertz time-domain spectroscopy [J].
Dorney, TD ;
Baraniuk, RG ;
Mittleman, DM .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (07) :1562-1571