Analysis of the accuracy of methods for the direct measurement of emissivity

被引:60
作者
Perez-Saez, Raul B. [1 ,2 ]
del Campo, Leire [1 ]
Tello, Manuel J. [1 ,2 ]
机构
[1] Univ Basque Country, Fac Ciencias & Tecnol, Dept Fis Mat Condensada, Leioa 48940, Bizkaia, Spain
[2] Univ Basque Country, Inst Sintesis & Estudio Mat, E-48080 Bilbao, Spain
关键词
direct measurement; emissivity; radiometry; systematic error;
D O I
10.1007/s10765-008-0402-4
中图分类号
O414.1 [热力学];
学科分类号
摘要
Emissivity measurements are of great interest for both theoretical studies and technological applications. Emissivity is a property that specifies how much radiation a real body emits as compared to a blackbody. The emissivity determination of a sample should be an easy task: a simple comparison between the sample and blackbody radiation at the same temperature. Unfortunately, when measuring the emissivity, some practical problems arise due to the differences between the true emitted radiation and the detected quantity. To clarify this point, an analysis of different direct methods for emissivity measurement is presented. Furthermore, a method that includes multiple reflections is developed. The systematic errors associated with each method are computed theoretically as a function of wavelength, sample temperature, and emissivity, and the surrounding enclosure temperature and emissivity. In general, the error is very high for small sample enclosures, but it strongly decreases when the enclosure area increases. Although at short wavelengths all the analyzed methods produce similar errors, noticeable differences appear under other conditions, and methods considering more radiation terms do not always produce lower errors.
引用
收藏
页码:1141 / 1155
页数:15
相关论文
共 14 条
[1]   NOVEL EXPERIMENTAL-TECHNIQUE FOR MEASURING HIGH-TEMPERATURE SPECTRAL EMISSIVITIES [J].
BALLICO, MJ ;
JONES, TP .
APPLIED SPECTROSCOPY, 1995, 49 (03) :335-340
[2]   Fourier transform spectrometer for spectral emissivity measurement in the temperature range between 60 and 1500°C [J].
Dai, Jingmin ;
Wang, Xinbei ;
Yuan, Guibin .
7th International Symposium on Measurement Technology and Intelligent Instruments, 2005, 13 :63-66
[3]   New experimental device for infrared spectral directional emissivity measurements in a controlled environment [J].
del Campo, Leire ;
Perez-Saez, Raul B. ;
Esquisabel, Xabier ;
Fernandez, Ignacio ;
Tello, Manuel J. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (11)
[4]  
DELCAMPO L, 2007, THESIS U BASQUE COUN
[5]   Fourier-transform radiation thermometry: measurements and uncertainties [J].
Dufour, PC ;
Rowell, NL ;
Steele, AG .
APPLIED OPTICS, 1998, 37 (25) :5923-5931
[6]  
FONSECA V, 2000, THESIS U ORLEANS
[7]   Uncertainty estimation for emissivity measurements near room temperature with a Fourier transform spectrometer [J].
Ishii, J ;
Ono, A .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2001, 12 (12) :2103-2112
[8]   CALIBRATION OF A FOURIER-TRANSFORM SPECTROMETER USING 3 BLACKBODY SOURCES [J].
LINDERMEIR, E ;
HASCHBERGER, P ;
TANK, V ;
DIETL, H .
APPLIED OPTICS, 1992, 31 (22) :4527-4533
[9]   A new experimental device to measure directional spectral emittance of semitransparent media at high temperatures [J].
Lopes, R ;
Delmas, A ;
Sacadura, JF .
HIGH TEMPERATURES-HIGH PRESSURES, 2000, 32 (03) :369-376
[10]   Infrared optical properties of semitransparent pyrolytic boron nitride (pBN) [J].
Manara, J ;
Caps, R ;
Ebert, HP ;
Hemberger, F ;
Fricke, J ;
Seidl, A .
HIGH TEMPERATURES-HIGH PRESSURES, 2002, 34 (01) :65-72