Model -free control method based on reinforcement learning for building cooling water systems: Validation by measured data-based simulation

被引:57
作者
Qiu, Shunian [1 ]
Li, Zhenhai [1 ]
Li, Zhengwei [1 ,2 ]
Li, Jiajie [1 ]
Long, Shengping [3 ]
Li, Xiaoping [4 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai, Peoples R China
[2] Tongji Univ, Key Lab Performance Evolut & Control Engn Struct, Minist Educ, Shanghai, Peoples R China
[3] Shanghai East Low Carbon Technol Ind CO LTD, Shanghai, Peoples R China
[4] China Acad Bldg Res, Beijing, Peoples R China
关键词
Cooling water system; Cooling tower; Cooling water pump; Optimal control; Reinforcement learning; Model-free control; CHILLER SEQUENCING CONTROL; AIR-CONDITIONING SYSTEM; ONLINE FAULT-DETECTION; ENHANCED ROBUSTNESS; OPTIMIZATION; STRATEGY; ALGORITHM; OPERATION;
D O I
10.1016/j.enbuild.2020.110055
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the domain of optimal control for building HVAC systems, the performance of model-based control has been widely investigated and validated. However, the performance of model-based control highly depends on an accurate system performance model and sufficient sensors, which are difficult to obtain for certain buildings. To tackle this problem, a model-free optimal control method based on reinforcement learning is proposed to control the building cooling water system. In the proposed method, the wet bulb temperature and system cooling load are taken as the states, the frequencies of fans and pumps are the actions, and the reward is the system COP (i.e., the comprehensive COP of chillers, cooling water pumps, and cooling towers). The proposed method is based on Q-learning. Validated with the measured data from a real central chilled water system, a three-month measured data-based simulation is conducted under the supervision of four types of controllers: basic controller, local feedback controller, model-based controller, and the proposed model-free controller. Compared with the basic controller, the model-free controller can conserve 11% of the system energy in the first applied cooling season, which is greater than that of the local feedback controller (7%) but less than that of the model-based controller (14%). Moreover, the energy saving rate of the model-free controller could reach 12% in the second applied cooling season, after which the energy saving rate gets stabilized. Although the energy conservation performance of the model-free controller is inferior to that of the model-based controller, the model-free controller requires less a priori knowledge and sensors, which makes it promising for application in buildings for which the lack of accurate system performance models or sensors is an obstacle. Moreover, the results suggest that for a central chilled water system with a designed peak cooling load close to 2000 kW, three months of learning during the cooling season is sufficient to develop a good model-free controller with an acceptable performance. (c) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:21
相关论文
共 60 条
[41]   A review on buildings energy consumption information [J].
Perez-Lombard, Luis ;
Ortiz, Jose ;
Pout, Christine .
ENERGY AND BUILDINGS, 2008, 40 (03) :394-398
[42]   Stochastic optimized chiller operation strategy based on multi-objective optimization considering measurement uncertainty [J].
Qiu, Shunian ;
Feng, Fan ;
Zhang, Weijie ;
Li, Zhengwei ;
Li, Zhenhai .
ENERGY AND BUILDINGS, 2019, 195 :149-160
[43]   Data mining based framework to identify rule based operation strategies for buildings with power metering system [J].
Qiu, Shunian ;
Feng, Fan ;
Li, Zhengwei ;
Yang, Guang ;
Xu, Peng ;
Li, Zhenhai .
BUILDING SIMULATION, 2019, 12 (02) :195-205
[44]   A quick auto-calibration approach based on normative energy models [J].
Qiu, Shunian ;
Li, Zhengwei ;
Pang, Zhihong ;
Zhang, Weijie ;
Li, Zhenhai .
ENERGY AND BUILDINGS, 2018, 172 :35-46
[45]   Supervisory and optimal control of building HVAC systems: A review [J].
Shengwei Wang ;
Zhenjun Ma .
HVAC&R RESEARCH, 2008, 14 (01) :3-32
[46]  
Sulaiman Mohd Herwan, 2015, Applied Mechanics and Materials, V793, P500, DOI 10.4028/www.scientific.net/AMM.793.500
[47]   Multiplexed optimization for complex air conditioning systems [J].
Sun, Yongjun ;
Huang, Gongsheng ;
Li, Zhengwei ;
Wang, Shengwei .
BUILDING AND ENVIRONMENT, 2013, 65 :99-108
[48]   Chiller sequencing control with enhanced robustness for energy efficient operation [J].
Sun, Yongjun ;
Wang, Shengwei ;
Huang, Gongsheng .
ENERGY AND BUILDINGS, 2009, 41 (11) :1246-1255
[49]  
Sutton RS, 2018, ADAPT COMPUT MACH LE, P1
[50]   A comparison of empirically based steady-state models for vapor-compression liquid chillers [J].
Swider, DJ .
APPLIED THERMAL ENGINEERING, 2003, 23 (05) :539-556