Control Evaluations of Semiactive Fluid-Elastomeric Helicopter Lag Damper

被引:7
|
作者
Kothera, Curt S. [1 ]
Ngatu, Grum T. [2 ]
Wereley, Norman M. [2 ]
机构
[1] Technosciences Inc, Beltsville, MD 20705 USA
[2] Univ Maryland, Smart Struct Lab, Dept Aerosp Engn, College Pk, MD 20742 USA
关键词
MODEL;
D O I
10.2514/1.51434
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
A semiactive magnetorheological fluid-elastomeric device has been assembled and evaluated in control experiments to demonstrate its utility to compensate for measured changes as a helicopter lag damper. The baseline used in this study was lag damper (snubber) for a hingeless helicopter rotor that employs both elastomers and fluids: that is, a fluid-elastomeric damper. This damper was disassembled and modified to include two internal magnetorheological control valves, and the existing hydraulic fluid was replaced with magnetorheological fluid. Hence, the resulting prototype damper is a retrofit design that can easily be installed in a test rotor in future evaluations. The magnetorheological fluid-elastomeric damper was subject to extensive performance characterization at displacement amplitudes ranging from 0.8 to 3.4 mm, temperatures ranging from 20 to 55 degrees C, and control currents up to 2.0 A. Using this database and a hydromechanical model of the damper, control systems were designed to track a reference damping profile, which is a function of amplitude only, in the presence of measured amplitude and temperature variations at the rotor lag frequency (3.8 Hz). Both open-loop (interpolating lookup table) and closed-loop (proportional-integral and gain scheduling) techniques were employed in simulations and experiments. The results demonstrated that all of the control schemes were effective, although a minimum tracking error was achieved with the closed-loop systems. Comparing the two closed-loop systems, the gain-scheduling controller provided a faster response overall, but the improvement was marginal.
引用
收藏
页码:1143 / 1156
页数:14
相关论文
共 50 条
  • [21] Influence of elastomeric damper modeling on the dynamic response of helicopter rotors
    Kunz, DL
    AIAA JOURNAL, 1997, 35 (02) : 349 - 354
  • [22] The effect of the elastomeric damper on the dynamics of helicopter tail rotor shaft
    Dikmen, E.
    Isci, H.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2014) AND INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2014), 2014, : 4095 - 4109
  • [23] Magnetorheological fluid damper feedback linearization control for helicopter rotor application
    Gandhi, F
    Wang, KW
    Xia, LB
    SMART MATERIALS & STRUCTURES, 2001, 10 (01): : 96 - 103
  • [24] Semiactive vibration control of a smart seat with an MR fluid damper considering its time delay
    Park, CH
    Jeon, DY
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2002, 13 (7-8) : 521 - 524
  • [25] Simulation of damaged lag damper on helicopter rotor test rig
    Institute of Vibration Engineering, NUAA, Nanjing 210016, China
    Zhendong Ceshi Yu Zhenduan, 2006, 3 (200-202):
  • [26] Elastomer modelling for use in predicting helicopter lag damper behavior
    Kunz, DL
    JOURNAL OF SOUND AND VIBRATION, 1999, 226 (03) : 585 - 594
  • [27] A proposal of a nonlinear H-infinity control method for a semiactive damper with a magnetic fluid base
    Nakagawa, T
    Sagara, N
    IEEE TRANSACTIONS ON MAGNETICS, 1997, 33 (05) : 4206 - 4208
  • [28] Resetting semiactive stiffness damper for seismic response control
    Yang, JN
    Kim, JH
    Agrawal, AK
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2000, 126 (12): : 1427 - 1433
  • [29] Semiactive tuned mass damper for floor vibration control
    Setareh, Mehdi
    Ritchey, John K.
    Murray, Thomas M.
    Koo, Jeong-Hoi
    Ahmadian, Mehdi
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (02): : 242 - 250
  • [30] Semiactive nonlinear control of a building with a magnetorheological damper system
    Kim, Yeesock
    Langari, Reza
    Hurlebaus, Stefan
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2009, 23 (02) : 300 - 315