Surface dose measurement for helical tomotherapy

被引:8
作者
Snir, Jonatan A. [1 ]
Mosalaei, Homeira [1 ]
Jordan, Kevin [1 ,2 ,3 ]
Yartsev, Slav [1 ,2 ,3 ]
机构
[1] London Hlth Sci Ctr, London Reg Canc Program, London, ON N6A 4L6, Canada
[2] Univ Western Ontario, Dept Oncol, London, ON N6A 3K7, Canada
[3] Univ Western Ontario, Dept Med Biophys, London, ON N6A 3K7, Canada
关键词
helical tomotherapy; OSL dosimeter; MOSFET dosimeter; skin dose; MOSFET; HEAD;
D O I
10.1118/1.3592021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the surface dose measurements made by different dosimeters for the helical tomotherapy (HT) plan in the case of the target close to the surface. Methods: Surface dose measurements in different points for the HT plan to deliver 2 Gy to the planning target volume (PTV) at 5 mm below the surface of the cylindrical phantom were performed by radiochromic films, single use metal oxide semiconductor field-effect transistor (MOSFET) dosimeters, silicon IVD QED diode, and optically stimulated luminescence (OSL) dosimeters. Results: The measured doses by all dosimeters were within 12 +/- 8% difference of each other. Conclusions: Radiochromic films, EBT, and EBT(2), provide high spatial resolution, although it is difficult to get accurate measurements of dose. Both the OSL and QED measured similar dose to that of the MOSFET detectors. The QED dosimeter is promising as a reusable on-line wireless dosimeter, while the OSL dosimeters are easier to use, require minimum setup time and are very precise. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3592021]
引用
收藏
页码:3104 / 3107
页数:4
相关论文
共 50 条
  • [41] Fluence-weighted average subfield size in helical TomoTherapy
    Howitz, Simon
    Wiezorek, Tilo
    Wittig, Andrea
    Vorwerk, Hilke
    Zink, Klemens
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2019, 29 (04): : 337 - 348
  • [42] CONCURRENT CHEMORADIOTHERAPY WITH HELICAL TOMOTHERAPY FOR OROPHARYNGEAL CANCER: A PRELIMINARY RESULT
    Shueng, Pei-Wei
    Wu, Le-Jung
    Chen, Shiou-Yi
    Hsiao, Chi-Huang
    Tien, Hui-Ju
    Cheng, Po-Wen
    Kuo, Ying-Shiung
    Chen, Yu-Jen
    Chen, Chien-An
    Hsieh, Pei-Ying
    Hsieh, Chen-Hsi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (03): : 715 - 721
  • [43] On the complexity of helical tomotherapy treatment plans
    Santos, Tania
    Ventura, Tiago
    Mateus, Josefina
    Capela, Miguel
    Lopes, Maria do Carmo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 107 - 118
  • [44] Helical tomotherapy: description and clinical applications
    Dejean, C.
    Kantor, G.
    de Figueiredo, B. Henriques
    Lisbona, A.
    Mahe, M. -A.
    Mervoyer, A.
    Zefkili, S.
    Yassa, M.
    Giraud, P.
    BULLETIN DU CANCER, 2010, 97 (07) : 783 - 789
  • [45] Dosimetric and clinical review of helical tomotherapy
    Rong, Yi
    Welsh, James S.
    EXPERT REVIEW OF ANTICANCER THERAPY, 2011, 11 (02) : 309 - 320
  • [46] Impact of the spinal cord position uncertainty on the dose received during head and neck helical tomotherapy
    Piotrowski, Tomasz
    Kazmierska, Joanna
    Sokolowski, Adam
    Skorska, Malgorzata
    Jodda, Agata
    Ryczkowski, Adam
    Cholewinski, Witold
    Bak, Bartosz
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 503 - 511
  • [47] Dose accumulation with deformable image registration method using helical tomotherapy images for prostate cancer
    Thongsuk, Warit
    Chitapanarux, Imjai
    Wanwilairat, Somsak
    Nobnop, Wannapha
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (01) : 25 - 29
  • [48] Surface dose and build-up region depth dose measurements in non-standard beams of Cyberknife and tomotherapy systems
    Jerrin, Amalraj
    Ramasubramanian, Velayudham
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2021, 14 (03) : 309 - 317
  • [49] Evaluation and Comparison of the Dose Received by the Mandible, Maxilla, and Teeth in Two Methods of Three-dimensional Conformal Radiation Therapy and Helical Tomotherapy
    Pourparvar, Zahra
    Shahbazi-Gahrouei, Daryoush
    Najafizade, Nadia
    Saeb, Mohsen
    Khaniabadi, Bita Moradi
    Khaniabadi, Pegah Moradi
    JOURNAL OF MEDICAL SIGNALS & SENSORS, 2024, 14 (09):
  • [50] The Influence of Different IMRT Techniques on the Peripheral Dose A Comparison between sMLM-IMRT and Helical Tomotherapy
    Wiezorek, Tilo
    Schwahofer, Andrea
    Schubert, Kai
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 (10) : 696 - 702