Absolute measurement of photon flux using ionization chamber in (6∼20) keV synchrotron radiation X-rays

被引:0
作者
Guo, Siming [1 ]
Wang, Peiwei [1 ]
Wang, Ji [1 ]
Li, Fan [2 ]
Wu, Jinjie [1 ]
Zhang, Jian [1 ]
机构
[1] Natl Inst Metrol, Div Ionizing Radiat Metrol, Beijing, Peoples R China
[2] Inst High Energy Phys, Beijing, Peoples R China
基金
国家重点研发计划;
关键词
DETECTOR CALIBRATION; RECOMBINATION; RADIOMETRY;
D O I
10.1002/xrs.3152
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Absolute measurement of photon flux under high-fluence rate X-rays was required in photon diagnostics for X-ray lasers. A free-air ionization chamber used for the reproducibility of air-kerma in high-fluence rate X-ray was designed, and the monoenergetic X-rays flux of (6-20) keV were absolutely measured on Beijing Synchrotron Radiation Facility. The energy spectrum of the monoenergetic X-rays was measured using a silicon drift detector, and the proportion of higher harmonics was determined. The saturation curve, air attenuation correction factor, and composite loss correction factor of the free-air ionization chamber were obtained experimentally. The air-kerma rate for the (6 similar to 20) keV monoenergetic X-ray was measured accurately, and the relative combined standard uncertainty of the air-kerma is 0.61%.
引用
收藏
页码:572 / 579
页数:8
相关论文
共 18 条
  • [1] X-ray detector calibration in the PTB radiometry laboratory at the electron storage ring BESSY II
    Beckhoff, B
    Klein, R
    Krumrey, M
    Scholze, F
    Thornagel, R
    Ulm, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 444 (1-2) : 480 - 483
  • [2] Volume recombination parameter in ionization chambers
    Boutillon, M
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (08) : 2061 - 2072
  • [3] Free-air ionization chambers
    Burns, D. T.
    Bueermann, L. B.
    [J]. METROLOGIA, 2009, 46 (02) : S9 - S23
  • [4] DERIKUM K, 2005, RADIOTHER ONCOL S2, V76, pS19
  • [5] Cryogenic radiometry in the hard x-ray range
    Gerlach, M.
    Krumrey, M.
    Cibik, L.
    Mueller, P.
    Rabus, H.
    Ulm, G.
    [J]. METROLOGIA, 2008, 45 (05) : 577 - 585
  • [6] The PTB high-accuracy spectral responsivity scale in the VUV and x-ray range
    Gottwald, A.
    Kroth, U.
    Krumrey, M.
    Richter, M.
    Scholze, F.
    Ulm, G.
    [J]. METROLOGIA, 2006, 43 (02) : S125 - S129
  • [7] Jinjie W., 2011, ACTA METEOROL SIN, V32, P9
  • [8] KESSLER C, 2011, METROLOGIA S, V48, DOI DOI 10.1088/0026-1394/48/1A/06014
  • [9] Klein R., Synchrotron Radiation News, V15, P23, DOI DOI 10.1080/08940880208602929
  • [10] Li H., 2017, DETECTOR CALIBRATION