Super high-flux membrane dialyzers improve mortality in patients on hemodialysis: a 3-year nationwide cohort study

被引:20
作者
Abe, Masanori [1 ,2 ]
Masakane, Ikuto [1 ,3 ]
Wada, Atsushi [1 ,4 ]
Nakai, Shigeru [1 ,5 ]
Nitta, Kosaku [1 ,6 ]
Nakamoto, Hidetomo [1 ,7 ]
机构
[1] Japanese Soc Dialysis Therapy, Comm Renal Data Registry, Tokyo, Japan
[2] Nihon Univ, Dept Internal Med, Div Nephrol Hypertens & Endocrinol, Sch Med, Tokyo, Japan
[3] Yabuki Hosp, Yamagata, Japan
[4] Kitasaito Hosp, Dept Nephrol, Asahikawa, Hokkaido, Japan
[5] Fujita Hlth Univ, Dept Clin Engn, Toyoake, Aichi, Japan
[6] Tokyo Womens Med Univ, Dept Nephrol, Tokyo, Japan
[7] Saitama Med Univ, Dept Gen Internal Med, Saitama, Japan
关键词
beta(2)-microglobulin; hemodialysis; high-flux dialyzer; low-flux dialyzer; super high-flux dialyzer; THERAPY CLINICAL GUIDELINE; REGULAR DIALYSIS TREATMENT; JAPANESE SOCIETY; HEMODIAFILTRATION; OUTCOMES;
D O I
10.1093/ckj/sfab177
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction In Japan, dialyzers are classified based on beta(2)-microglobulin clearance. Type I dialyzers are classified as low-flux dialyzers (<10 mL/min clearance), type II and III as high-flux dialyzers (>= 10 to <30 mL/min and >= 30 to <50 mL/min clearance, respectively), and type IV and V as super high-flux dialyzers (>= 50 to <70 mL/min and >= 70 mL/min clearance, respectively). Super high-flux dialyzers are commonly used, but their superiority over low-flux dialyzers is controversial. Methods In this nationwide prospective cohort study, we analyzed Japanese Society for Dialysis Therapy Renal Data Registry data collected at the end of 2008 and 2011. We enrolled 242,467 patients on maintenance hemodialysis and divided them into five groups by dialyzer type. We assessed the associations of each dialyzer type with 3-year all-cause mortality using Cox proportional hazards models and performed propensity score matching analysis, adjusting for potential confounders. Results By the end of 2011, 53,172 (21.9%) prevalent dialysis patients had died. Mortality significantly decreased according to dialyzer type. Hazard ratios (HRs) were significantly higher for type I, II and III compared with type IV (reference) after adjustment for basic factors and further adjustment for dialysis-related factors. HR was significantly higher for type I, but significantly lower for type V, after further adjustment for nutrition- and inflammation-related factors. These significant findings were also evident after propensity score matching. Conclusions Hemodialysis using super high-flux dialyzers might reduce mortality. Randomized controlled trials are warranted to clarify whether these type V dialyzers can improve prognosis.
引用
收藏
页码:473 / 483
页数:11
相关论文
共 42 条
  • [11] Effect of dialysis dose and membrane flux in maintenance hemodialysis.
    Eknoyan, G
    Beck, GJ
    Cheung, AK
    Daugirdas, JT
    Greene, T
    Kusek, JW
    Allon, M
    Bailey, J
    Delmez, JA
    Depner, TA
    Dwyer, JT
    Levey, AS
    Levin, NW
    Milford, E
    Ornt, DB
    Rocco, MV
    Schulman, G
    Schwab, SJ
    Teehan, BP
    Toto, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (25) : 2010 - 2019
  • [12] Cytokine Removal in Extracorporeal Blood Purification: An in vitro Study
    Harm, Stephan
    Schildboeck, Claudia
    Hartmann, Jens
    [J]. BLOOD PURIFICATION, 2020, 49 (1-2) : 33 - 43
  • [13] Modalities of Hemodialysis: Quality Improvement
    Karkar, Ayman
    [J]. SAUDI JOURNAL OF KIDNEY DISEASES AND TRANSPLANTATION, 2012, 23 (06) : 1145 - 1161
  • [14] Did 20 Years of Technological Innovations in Hemodialysis Contribute to Better Patient Outcomes?
    Lameire, Norbert
    Van Biesen, Wim
    Vanholder, Raymond
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 : S30 - S40
  • [15] Locatelli F, 2009, J AM SOC NEPHROL, V20, P645, DOI 10.1681/ASN.2008060590
  • [16] EFFECT OF THE HEMODIALYSIS PRESCRIPTION ON PATIENT MORBIDITY - REPORT FROM THE NATIONAL COOPERATIVE DIALYSIS STUDY
    LOWRIE, EG
    LAIRD, NM
    PARKER, TF
    SARGENT, JA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (20) : 1176 - 1181
  • [17] High-permeability alternatives to current dialyzers performing both high-flux hemodialysis and postdilution online hemodiafiltration
    Maduell, Francisco
    Rodas, Lida
    Jesus Broseta, Jose
    Gomez, Miguel
    Xipell Font, Marc
    Molina, Alicia
    Montagud-Marrahi, Enrique
    Guillen, Elena
    Arias-Guillen, Marta
    Fontsere, Nestor
    Vera Rivera, Manel
    Rico, Nayra
    [J]. ARTIFICIAL ORGANS, 2019, 43 (10) : 1014 - 1021
  • [18] High-Efficiency Postdilution Online Hemodiafiltration Reduces All-Cause Mortality in Hemodialysis Patients
    Maduell, Francisco
    Moreso, Francesc
    Pons, Mercedes
    Ramos, Rosa
    Mora-Macia, Josep
    Carreras, Jordi
    Soler, Jordi
    Torres, Ferran
    Campistol, Josep M.
    Martinez-Castelao, Alberto
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2013, 24 (03): : 487 - 497
  • [19] Current approaches to middle molecule removal: room for innovation
    Masakane, Ikuto
    Sakurai, Kenji
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33 : 12 - 21
  • [20] Bacteriological Water Quality in the Central Dialysis Fluid Delivery System from the Survey of the Japanese Society for Dialysis Therapy
    Masakane, Ikuto
    Takemoto, Yoshiaki
    Nakai, Shigeru
    Tsubakihara, Yoshiharu
    Akiba, Takashi
    Watanabe, Yuzo
    Iseki, Kunitoshi
    [J]. BLOOD PURIFICATION, 2009, 27 : 11 - 16