Systematic investigation of the signal properties of polycrystalline HgI2 detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions

被引:32
作者
Su, Z [1 ]
Antonuk, LE [1 ]
El-Mohri, Y [1 ]
Hu, L [1 ]
Du, H [1 ]
Sawant, A [1 ]
Li, YX [1 ]
Wang, Y [1 ]
Yamamoto, J [1 ]
Zhao, QH [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48103 USA
关键词
D O I
10.1088/0031-9155/50/12/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The signal properties of polycrystalline mercuric iodide (HgI2) film detectors, under irradiation conditions relevant to mammographic, radiographic, fluoroscopic and radiotherapy x-ray imaging, are reported. Each film detector consists of an similar to 230 to similar to 460 mu m thick layer of HgI2 (fabricated through physical vapour deposition or a screen-print process) and a thin barrier layer, sandwiched between a pair of opposing electrode plates. The high atomic number, high density and low effective ionization energy, W-EFF, of HgI2 make it an attractive candidate for significantly improving the performance of active matrix, flat-panel imagers (AMFPls) for several x-ray imaging applications. The temporal behaviour of current from the film detectors in the presence and in the absence of radiation was used to examine dark current levels, the lag and reciprocity of the signal response, x-ray sensitivity and WEFF. The results are discussed in the context of present AMFPI performance. This study provides performance data for a wide range of potential medical x-ray imaging applications from a single set of detectors and represents the first investigation of the signal properties of polycrystalline mercuric iodide for the radiotherapy application.
引用
收藏
页码:2907 / 2928
页数:22
相关论文
共 49 条
[1]  
[Anonymous], 2000, TECHNOLOGY APPL AMOR
[2]   Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications [J].
Antonuk, LE ;
Jee, KW ;
El-Mohri, Y ;
Maolinbay, M ;
Nassif, S ;
Rong, X ;
Zhao, Q ;
Siewerdsen, JH ;
Street, RA ;
Shah, KS .
MEDICAL PHYSICS, 2000, 27 (02) :289-306
[3]   RADIATION RESPONSE OF AMORPHOUS-SILICON IMAGING ARRAYS AT DIAGNOSTIC ENERGIES [J].
ANTONUK, LE ;
SIEWERDSEN, JH ;
YORKSTON, J ;
HUANG, W .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1500-1505
[4]   Systematic development of input-quantum-limited fluoroscopic imagers based on active matrix, flat-panel technology [J].
Antonuk, LE ;
Zhao, QH ;
Su, Z ;
Yamamoto, J ;
El-Mohri, Y ;
Li, YX ;
Wang, Y ;
Sawant, A .
MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 :127-138
[5]   Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation [J].
Antonuk, LE ;
ElMohri, Y ;
Siewerdsen, JH ;
Yorkston, J ;
Huang, W ;
Scarpine, VE ;
Street, RA .
MEDICAL PHYSICS, 1997, 24 (01) :51-70
[6]   Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research [J].
Antonuk, LE .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (06) :R31-R65
[7]  
Antonuk LE., 2004, THIN FILM TRANSISTOR, V1, P395, DOI DOI 10.1007/978-1-4615-0397-2
[8]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[9]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[10]   RADIOLOGICAL IMAGING - 2000 AD [J].
CAPP, MP .
RADIOLOGY, 1981, 138 (03) :541-550