Fabrication and characterization of controlled release poly(D,L-lactide-co-glycolide) millirods

被引:0
作者
Qian, F [1 ]
Szymanski, A [1 ]
Gao, JM [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Canc Targeted Drug Delivery Lab, Cleveland, OH 44106 USA
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2001年 / 55卷 / 04期
关键词
controlled release drug delivery; poly(D; L-lactide-co-glycolide); compression-heat molding; polymer characterization;
D O I
10.1002/1097-4636(20010615)55:4<512::AID-JBM1044>3.3.CO;2-E
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A compression-heat molding procedure was developed to fabricate poly(D,L-lactide-co-glycolide) (PLGA) controlled release drug delivery devices fdr the local treatment of tumors. The drug delivery devices were designed in the shape of a cylindrical millirod (1.6-mm diameter, 10-mm length), which allows them to be implanted by a modified 14-gauge tissue biopsy needle into tumor tissues via image-guided interventional procedures. In this study, the prototype trypan blue-containing PLGA millirods were fabricated under a compression pressure of 4.6 x 10(6) Pa and different fabrication temperatures for 2 h. The scanning electron microscopy results showed complete polymer annealing for millirods fabricated at 80 and 90 degreesC, while the cross sections of the 60 and 70 degreesC millirods showed incompletely annealed PLGA microspheres and trypan blue powders. The density, flexural modulus, and release properties of the PLGA millirods were also characterized and compared. The average values of the density and flexural modulus of the millirods increased with an increase in fabrication temperature. The flexural modulus values of most PLGA millirods were above 1 x 10(8) Pa, which provides sufficient stiffness for implantation within the tumor tissue. In addition, a ac, method was developed to determine the loading density of trypan blue in the PLGA millirods by differential scanning calorimetry. Results from the Deltac(p), measurement showed that trypan blue was homogeneously distributed in the millirod. Release studies in phosphate-buffered saline showed that the release rate decreased for the millirods fabricated at higher temperatures. The times for the release of 50% trypan blue were 5, 25, 25, and 25 h for millirods fabricated at 60, 70, 80, and 90 degreesC, respectively. Millirods fabricated at 90 degreesC had the most reproducible release profiles. The results from this study established compression-heat molding as an effective method to fabricate controlled release PLGA millirods with sufficient mechanical strength and reproducible release profiles for local cancer therapy. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:512 / 522
页数:11
相关论文
共 37 条
[1]   Percutaneous treatment of liver tumours with interstitial radiofrequency thermal ablation [J].
Allgaier, HP ;
Deibert, P ;
Zuber, I ;
Blum, HE .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 123 (30) :907-911
[2]   High-resolution optical coherence tomography-guided laser ablation of surgical tissue [J].
Boppart, SA ;
Herrmann, J ;
Pitris, C ;
Stamper, DL ;
Brezinski, ME ;
Fujimoto, JG .
JOURNAL OF SURGICAL RESEARCH, 1999, 82 (02) :275-284
[3]  
Buscarini, 1997, Semin Laparosc Surg, V4, P96
[4]   THERMOABLATION TREATMENT FOR TRICHIASIS USING THE ARGON-LASER [J].
CAMPBELL, DC .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1990, 18 (04) :427-430
[5]   Kinetics of a model nucleoside (guanosine) release from biodegradable poly(DL-lactide-co-glycolide) microspheres:: A delivery system for long-term intraocular delivery [J].
Chowdhury, DK ;
Mitra, AK .
PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2000, 5 (02) :279-285
[6]   Experimental and clinical standards, and evolution of lasers in neurosurgery [J].
Devaux, BC ;
Roux, FX .
ACTA NEUROCHIRURGICA, 1996, 138 (10) :1135-1147
[7]   Minimally invasive treatment of malignant hepatic tumors: At the threshold of a major breakthrough [J].
Dodd, GD ;
Soulen, MC ;
Kane, RA ;
Livraghi, T ;
Lees, WR ;
Yamashita, Y ;
Gillams, AR ;
Karahan, OI ;
Rhim, H .
RADIOGRAPHICS, 2000, 20 (01) :9-27
[8]   Biocompatibility of poly (DL-lactide-co-glycolide) microspheres implanted into the brain [J].
Emerich, DF ;
Tracy, MA ;
Ward, KL ;
Figueiredo, M ;
Qian, RL ;
Henschel, C ;
Bartus, RT .
CELL TRANSPLANTATION, 1999, 8 (01) :47-58
[9]   Poly(D,L-lactic-co-glycolic acid) microspheres for sustained delivery and stabilization of camptothecin [J].
Ertl, B ;
Platzer, P ;
Wirth, M ;
Gabor, F .
JOURNAL OF CONTROLLED RELEASE, 1999, 61 (03) :305-317
[10]   Nanoparticulate delivery system of a tyrphostin for the treatment of restenosis [J].
Fishbein, I ;
Chorny, M ;
Rabinovich, L ;
Banai, S ;
Gati, I ;
Golomb, G .
JOURNAL OF CONTROLLED RELEASE, 2000, 65 (1-2) :221-229