Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation

被引:51
作者
Mayer, Wolfgang J. [1 ]
Kreutzer, Thomas [1 ]
Dirisamer, Martin [1 ]
Kern, Christoph [1 ]
Kortuem, Karsten [1 ]
Vounotrypidis, Efstathios [1 ]
Priglinger, Siegfried [1 ]
Kook, Daniel [1 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Ophthalmol, Munich, Germany
关键词
INTRAOPERATIVE ABERROMETRY; CATARACT-SURGERY; ASTIGMATISM; AXIS; SYSTEM; ORIENTATION;
D O I
10.1016/j.jcrs.2017.07.030
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the efficacy of a computer-assisted marker system for toric intraocular lenses (IOLs) (Callisto Eye System) with manual marking techniques. Setting: University Eye Hospital Munich, Ludwig-Maximilians-University, Munich, Germany. Design: Prospective case series. Methods: This study included patients having cataract surgery with implantation of a toric IOL (Torbi 709 M). They were randomly assigned to 1 of 2 groups based on the marking system used, manual or digital. Patients were included if they had age-related cataract and a regular comeal astigmatism of 1.25 diopters (D) or higher. Visual and refractive outcomes as well as rotational stability were evaluated. Vector analysis was performed to evaluate total astigmatic changes. Results: The study comprised 57 eyes of 29 patients; there were 28 eyes in the manual group and 29 eyes in the digital group. The mean toric IOL misalignment was significantly lower in the digital group than in the manual group (2.0 degrees +/- 1.86 [SD] versus 3.4 +/- 2.37 degrees; P = .026). The mean deviation from the target induced astigmatism was significantly lower in the digital group (0.10 +/- 0.08 D versus 0.22 +/- 0.14 D; P = .008). During surgery, the mean toric IOL alignment time was significantly shorter in the digital group (37.2 +/- 11.9 seconds versus 59.4 +/- 15.3 seconds; P = .003). The mean overall time required to perform the surgery was significantly shorter in the digital group (727.2 +/- 198.4 seconds versus 1110.0 +/- 382.2 seconds; P < .001). Conclusions: A digital tracking approach for toric IOL alignment was efficient and safe to improve refractive outcomes. Furthermore, image-guided surgery helped streamline the workflow in refractive cataract surgery. (C) 2017 ASCRS and ESCRS
引用
收藏
页码:1281 / 1286
页数:6
相关论文
共 24 条
[1]   Astigmatism analysis by the Alpins method [J].
Alpins, N .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) :31-49
[2]   New method of targeting vectors to treat astigmatism [J].
Alpins, NA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (01) :65-75
[3]   An easy and practical method for toric intraocular lens implantation: marking corneal astigmatic axis at slit-lamp [J].
Bayramlar, Huseyin ;
Dag, Yasar ;
Karadag, Remzi ;
Cakici, Ozgur .
INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (01) :179-184
[4]   Anterior stromal puncture with staining: A modified technique for preoperative reference corneal marking for toric lenses and its retrospective analyses [J].
Bhandari, Sahil ;
Nath, Manas .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (08) :559-562
[5]   New Axis-marking Method for a Toric Intraocular Lens: Mapping Method [J].
Cha, Deoksun ;
Kang, Su Yeon ;
Kim, Seung-Hyun ;
Song, Jong-Suk ;
Kim, Hyo-Myung .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (05) :375-379
[6]   Accuracy of toric intraocular lens axis alignment using a 3-dimensional computer-guided visualization system [J].
de Oca, Ildamaris Montes ;
Kim, Eric J. ;
Wang, Li ;
Weikert, Mitchell P. ;
Khandelwal, Sumitra S. ;
Al-Mohtaseb, Zaina ;
Koch, Douglas D. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04) :550-555
[7]   Comparison Between Digital and Manual Marking for Toric Intraocular Lenses A Randomized Trial [J].
Elhofi, Abdel Hamid ;
Helaly, Hany Ahmed .
MEDICINE, 2015, 94 (38)
[8]   Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker [J].
Farooqui, Javed Hussian ;
Koul, Archana ;
Dutta, Ranjan ;
Shroff, Noshir Minoo .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (05) :703-706
[9]   Simplified system of marking the cornea for a toric intraocular lens [J].
Graether, John M. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (09) :1498-1500
[10]   Comments on corneal astigmatic marking methods [J].
Jain, Arun K. ;
Gupta, Raghav ;
Chakma, Partha .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06) :966-967