Evaluation of hyperspectral imaging technology in patients with peripheral vascular disease

被引:44
作者
Chiang, Nathaniel [1 ]
Jain, Jitendra K. [2 ]
Sleigh, Jamie [1 ]
Vasudevan, Thodur [1 ]
机构
[1] Waikato Hosp, Dept Vasc Surg, Hamilton, New Zealand
[2] Royal Melbourne Hosp, Melbourne, Vic, Australia
关键词
TRANSCUTANEOUS OXYGEN; FOOT ULCERATION; TENSION; OXIMETRY; ULCERS;
D O I
10.1016/j.jvs.2017.02.047
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Hyperspectral imaging technology is a novel method of using transcutaneous measurement of oxyhemoglobin (HT-Oxy) and deoxyhemoglobin (HT-Deoxy) concentrations to create a two-dimensional, color-coded "oxygen map." The aims of this study were to compare the use of a hyperspectral imaging device with the transcutaneous oxygen measurement (TCOM), ankle-brachial index (ABI), and severity of peripheral vascular disease (PVD) and to assess their correlations. Methods: This prospective study recruited 294 participants divided into three distinct groups composed of healthy volunteers and patients with PVD. Patients underwent measurements of lower limbs at a standardized point over the head of the first metatarsal on the plantar aspect using the hyperspectral imaging device, generating four outputs including HT-Oxy, HT-Deoxy, oxygen saturation (HT-Sat), and skin temperature, and the TCOM system, generating transcutaneous partial pressure of oxygen (TcpO(2)) and carbon dioxide (TcpCO(2)). Demographic data, severity of PVD, ABI, and other pertinent information were obtained from both the participants and medical records. Results: Interoperator reliability ranged from 86% to 94% across the four hyperspectral imaging device outputs, whereas intraoperator reliability ranged from 92% to 94%. The HT-Oxy, HT-Sat, TcpCO(2), and ABI of the diseased limb correlated significantly with the severity of PVD. HT-Sat significantly correlated with TcpO(2) (R = 0.19), TcpCO(2) (R = -0.26), ABI (R = 0.42), and skin temperature (R = 0.56). HT-Deoxy also correlated with TcpCO(2) (R = 0.27). Conclusions: This study demonstrates the reliability of hyperspectral imaging in comparison to TCOM, ABI, skin temperature, and severity of PVD in a series of patients. Its correlation to other established modalities and low interoperator and intraoperator variability could enable this modality to be a useful screening tool in PVD.
引用
收藏
页码:1192 / 1201
页数:10
相关论文
共 29 条
[1]  
Baylor DS, ANN SCI M MAUI HAW J
[2]   Bland-Altman analysis as an alternative approach for statistical evaluation of agreement between two methods for measuring hemodynamics during acute myocardial infarction [J].
Brazdzionyte, Julija ;
Macas, Andrius .
MEDICINA-LITHUANIA, 2007, 43 (03) :208-214
[3]   TRANS-CUTANEOUS OXYGEN MEASUREMENT IN PERIPHERAL OCCLUSIVE DISEASE - AN INDICATOR OF WOUND-HEALING IN LEG AMPUTATION [J].
CHRISTENSEN, KS ;
KLARKE, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03) :423-426
[4]   COMPARATIVE DIAGNOSTIC-VALUE OF ANKLE-TO-BRACHIAL INDEX AND TRANSCUTANEOUS OXYGEN-TENSION AT REST AND AFTER EXERCISE IN PATIENTS WITH INTERMITTENT CLAUDICATION [J].
DEGROOTE, P ;
MILLAIRE, A ;
DEKLUNDER, G ;
MARACHE, P ;
DECOULX, E ;
DUCLOUX, G .
ANGIOLOGY, 1995, 46 (02) :115-122
[5]  
Dooley J, 1997, UNDERSEA HYPERBAR M, V24, P235
[6]  
Dowd G S, 1987, Ann R Coll Surg Engl, V69, P31
[7]  
Fife CE, 2009, UNDERSEA HYPERBAR M, V36, P43
[8]   Early changes in the skin microcirculation and muscle metabolism of the diabetic foot [J].
Greenman, RL ;
Panasyuk, S ;
Wang, X ;
Lyons, TE ;
Dinh, T ;
Longoria, L ;
Giurini, JM ;
Freeman, J ;
Khaodhiar, L ;
Veves, A .
LANCET, 2005, 366 (9498) :1711-1717
[9]   FETAL AND MATERNAL PTCO2 MONITORING [J].
HUCH, R ;
HUCH, A .
CRITICAL CARE MEDICINE, 1981, 9 (10) :694-697
[10]   Hyperspectral Image Measurements of Skin Hemoglobin Compared With Transcutaneous PO2 Measurements [J].
Jafari-Saraf, Lida ;
Wilson, Samuel E. ;
Gordon, Ian L. .
ANNALS OF VASCULAR SURGERY, 2012, 26 (04) :537-548