OBJECTIVE- To use a portable continuous glucose monitoring system (CGMS) to evaluate how well the customary intermittent self-monitoring of blood glucose (SMBG) correlates with integrated values during the surrounding time periods in ambulatory patients with type I diabetes. RESEARCH DESIGN AND METHODS- in the study, 18 young patients with type I diabetes were monitored with CGMS for up to 72 h, during which they continued to perform the four standard SMBG tests (preprandial and bedtime). Correlations were examined between each of the four standard SMBG tests and the mean CGMS values from defined periods that preceded and followed. We also tested how well a low bedtime SMBG predicted nocturnal hypoglycemia. RESULTS- Strong correlations were found between 1) SMBG at breakfast and the mean CGMS value for the preceding 8 h (r = 0.7514), 2) SMBG at dinner and the CGMS from lunch to dinner (r = 0.7538),3) SMBG at bedtime and the CGMS from dinner to bedtime (r = 0.8145), and 4) SMBG at bedtime and the CGMS from bedtime to breakfast (r = 0.6463). The remaining correlations were weak and not statistically significant. These correlations seem independent of insulin-delivery method as virtually identical results were obtained when data from patients on conventional versus intensive regimes were separately analyzed. A bedtime SMBG < 7 mmol/l did not predict nocturnal hypoglycemia (defined as at least one CGMS value < 3). CONCLUSIONS- The breakfast and dinnertime SMBG values are good indicators of integrated glucose values in the time period preceding them, while the bedtime test correlates well with the integrated values both preceding and following it. This information should aid in the meaningful use of SMBG to evaluate glycemic control and make insulin dose adjustments.
引用
收藏
页码:1603 / 1606
页数:4
相关论文
共 50 条
  • [1] Continuous glucose monitoring on the ICU using a subcutaneous sensor
    Punke, M. A.
    Decker, C.
    Wodack, K.
    Reuter, D. A.
    Kluge, S.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2015, 110 (05) : 360 - 363
  • [2] A MEMS SENSOR FOR CONTINUOUS MONITORING OF GLUCOSE IN SUBCUTANEOUS TISSUE
    Huang, X.
    Li, S.
    Schultz, J.
    Wang, Q.
    Lin, Q.
    IEEE 22ND INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2009), 2009, : 352 - 355
  • [3] Timing of changes in interstitial and blood glucose measured with a continuous subcutaneous glucose sensor
    Boyne, MS
    Silver, DM
    Kaplan, J
    Saudek, CD
    DIABETES, 2000, 49 : A99 - A99
  • [4] Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    Boyne, MS
    Silver, DM
    Kaplan, J
    Saudek, CD
    DIABETES, 2003, 52 (11) : 2790 - 2794
  • [5] Blood glucose and subcutaneous continuous glucose monitoring in critically ill horses: A pilot study
    Vitale, Valentina
    Berg, Lise C.
    Larsen, Bettina Birch
    Hannesdottir, Andrea
    Dybdahl Thomsen, Preben
    Laursen, Sigrid Hyldahl
    Verwilghen, Denis
    van Galen, Gaby
    PLOS ONE, 2021, 16 (02):
  • [6] TOWARDS CONTINUOUS GLUCOSE MONITORING - INVIVO EVALUATION OF A MINIATURIZED GLUCOSE SENSOR IMPLANTED FOR SEVERAL DAYS IN RAT SUBCUTANEOUS TISSUE
    MOATTISIRAT, D
    CAPRON, E
    POITOUT, V
    REACH, G
    BINDRA, DS
    ZHANG, Y
    WILSON, GS
    THEVENOT, DR
    DIABETOLOGIA, 1992, 35 (03) : 224 - 230
  • [7] AN ENZYME SENSOR FOR CONTINUOUS GLUCOSE MONITORING IN UNDILUTED BLOOD
    FISCHER, U
    ABEL, P
    FREYSE, EJ
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1983, 6 (03): : 168 - 168
  • [8] A glucose sensor protein for continuous glucose monitoring
    Veetil, Jithesh V.
    Jin, Sha
    Ye, Kaiming
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04): : 1650 - 1655
  • [9] Subcutaneous a continuous glucose monitoring - Feasibility of a new microdialysis-based glucose sensor system
    Jungheim, K
    Wientjes, KJ
    Heinemann, L
    Lodwig, V
    Koschinsky, T
    Koschinsky, T
    Schoonen, AJ
    DIABETES CARE, 2001, 24 (09) : 1696 - 1697
  • [10] SUBCUTANEOUS CONTINUOUS GLUCOSE MONITORING: A COMPARISON
    Albuquerque, Andrea
    NURSING IN CRITICAL CARE, 2021, 26 : 29 - 29