Fabrication of graphene/Fe3O4@polythiophene nanocomposite and its application in the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from environmental water samples

被引:132
|
作者
Mehdinia, Ali [1 ]
Khodaee, Nader [2 ]
Jabbari, Ali [2 ]
机构
[1] Iranian Natl Inst Oceanog & Atmospher Sci, Dept Marine Sci, Tehran, Iran
[2] K N Toosi Univ Technol, Fac Sci, Dept Chem, Tehran, Iran
关键词
Graphene/Fe3O4@polythiophene; Magnetic solid phase extraction; Nanocamposite; Polycyclic aromatic hydrocarbons; Seawater; COATED FE3O4 NANOPARTICLES; GRAPHENE SHEETS; SORBENT; PERFORMANCE; ADSORPTION; POLYTHIOPHENE; ADSORBENT; FACILE; FUNCTIONALIZATION; MECHANISM;
D O I
10.1016/j.aca.2014.12.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polythiophene (PT) was used as a surface modifier of graphene/Fe3O4 (G/Fe3O4) composite to increase merit of it, and also overcome some limitations and disadvantages of using G/Fe3O4 alone as solid phase extraction (SPE) sorbent. An in-situ chemical polymerization method was employed to prepare G/Fe3O4@PT nanocomposites. Application of this newly designed material in the magnetic SPE (MSPE) of polycyclic aromatic hydrocarbons (PAHs), as model analytes, in the environmental water samples was investigated. The characterization of the hybrid material was performed using transmission electron microscopy, scanning electron microscopy, energy-dispersive X-ray analysis, Fourier transform-infrared (FT-IR) spectroscopy and vibrating sample magnetometry. Seven important parameters, affecting the extraction efficiency of PAHs, including: amount of adsorbent, adsorption and desorption times, type and volume of the eluent solvent, initial sample volume and salt content of the sample were evaluated. The optimum extraction conditions were obtained as: 4 min for extraction time, 20 mg for sorbent amount, 100 mL for initial sample volume, toluene as desorption solvent, 0.6 mL for desorption solvent volume, 6 min for desorption time and 30% (w/v) for NaCl concentration. Good performance data were obtained at the optimized conditions. Detection limits were in the range of 0.009-0.020 mu g L-1 in the real matrix. The calibration curves were linear over the concentration ranges from 0.03 to 80 mu g L-1 with correlation coefficients (R-2) between 0.995 and 0.998 for all the analytes. Relative standard deviations were ranged from 4.3 to 6.3%. Appropriate recovery values, in the range of 83-107%, were also obtained for the real sample analysis. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [21] A π-hole bond functionalized magnetic nanosorbent for the solid phase extraction of 15 polycyclic aromatic hydrocarbons from environmental water samples
    Xu, Shao Nan
    Feng, Ya Jie
    Luo, Si Yan
    Song, Rui
    Yan, Xiao Qing
    JOURNAL OF CHROMATOGRAPHY A, 2025, 1741
  • [22] Magnetic hybrid support for ultrasound-assisted magnetic solid-phase extraction of polycyclic aromatic hydrocarbons from produced water
    Lima de Barros Gaetano, Vinicius Crispim
    Cunha, Graziele da Costa
    Matos Oliveira, Rhayza Victoria
    Alexandre, Marcelo da Rosa
    Cruz Romao, Luciane Pimenta
    MICROCHEMICAL JOURNAL, 2019, 146 : 1195 - 1203
  • [23] Fe3O4@MOF core-shell magnetic microspheres for magnetic solid-phase extraction of polychlorinated biphenyls from environmental water samples
    Chen, Xiangfeng
    Ding, Ning
    Zang, Hao
    Yeung, Hoisze
    Zhao, Ru-Song
    Cheng, Chuange
    Liu, Jianhua
    Chan, T. -W. Dominic
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1304 : 241 - 245
  • [24] Preparation of polydopamine coated Fe3O4 nanoparticles and their application for enrichment of polycyclic aromatic hydrocarbons from environmental water samples
    Wang, Yixuan
    Wang, Saihua
    Niu, Hongyun
    Ma, Yurong
    Zeng, Tao
    Cai, Yaqi
    Meng, Zhaofu
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1283 : 20 - 26
  • [25] Solid phase extraction of 16 polycyclic aromatic hydrocarbons from environmental water samples by π-hole bonds
    Yan, Xiao Qing
    Guo, Ya Nan
    Zheng, Su Jin
    Liu, Qiu Shuang
    Zhang, Jia Ling
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1645
  • [26] Facile fabrication of naphthalene-functionalized magnetic nanoparticles for efficient extraction of polycyclic aromatic hydrocarbons from environmental water and fish samples
    Peng, Xitian
    Liu, Li
    Hu, Xizhou
    Yan, Wei
    Zheng, Dan
    Xia, Zhenzhen
    Yu, Qiongwei
    Zhou, Youxiang
    Xia, Hong
    Peng, Lijun
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1706
  • [27] Facile magnetization of metal-organic framework MIL-101 for magnetic solid-phase extraction of polycyclic aromatic hydrocarbons in environmental water samples
    Huo, Shu-Hui
    Yan, Xiu-Ping
    ANALYST, 2012, 137 (15) : 3445 - 3451
  • [28] A hybrid material composed of graphitic carbon nitride and magnetite (Fe3O4) for magnetic solid-phase extraction of trace levels of hydroxylated polycyclic aromatic hydrocarbons
    Nian, Qixun
    Wang, Xuesheng
    Wang, Manman
    Zuo, Guifu
    MICROCHIMICA ACTA, 2019, 186 (08)
  • [29] Development of novel magnetic solid-phase extraction sorbent based on Fe3O4/carbon nanosphere/polypyrrole composite and their application to the enrichment of polycyclic aromatic hydrocarbons from water samples prior to GC-FID analysis
    Abbasi, Sajjad
    Sarafraz-Yazdi, Ali
    Amiri, Amirhassan
    Ghaemi, Ferial
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2018, 15 (01) : 153 - 161
  • [30] Amino-functionalized Nano Fe3O4 Adsorbent for Magnetic Solid Phase Extraction of Polycyclic Aromatic Hydrocarbons from Environment Water Sample
    Wu, Yue
    Wang, Li
    Wang, Xiao-Nan
    Yan, Xiao-Qing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (07) : 1093 - 1102