Pupil Size Estimation Based on Spatially Weighted Corneal Flux Density

被引:6
作者
Zhang, Yuning [1 ]
Li, Shuai [1 ]
Wang, Jiang [1 ]
Wang, Ping [1 ]
Tu, Yan [1 ]
Li, Xiaohua [1 ]
Wang, Baoping [1 ]
机构
[1] Southeast Univ, Sch Elect Sci & Engn, Joint Int Res Lab Informat Display & Visualizat, Nanjing 210096, Jiangsu, Peoples R China
来源
IEEE PHOTONICS JOURNAL | 2019年 / 11卷 / 06期
基金
国家重点研发计划;
关键词
Pupil Size; corneal flux density; display luminance; light environment; visual optics; FIELD; LIGHT;
D O I
10.1109/JPHOT.2019.2948223
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The pupil size is an important parameter in different studies on vision and ophthalmology. A pupil size estimation model is constantly needed when actual measurements are unavailable. The reported pupil estimation models commonly adopt the product of light intensity and viewing field area, supposing the light contributes uniformly across the spatial domain. In this paper, the pupil diameters were measured for stimuli with different intensities and different sizes. Spatially varying effect were observed, especially for large field stimuli and annular bright stimuli. A spatially weighted flux density is proposed which shows a high correlation with pupil diameters. A hyperbolic equation is fitted to estimate the natural pupil diameter with independent light spatial distributions. The goodness of fit R-2 reaches 0.97. The accuracy of the model is further verified with a natural indoor scene for different viewing distances and different illumination levels. The model predicted pupil diameters show a high correlation with the measured data.
引用
收藏
页数:10
相关论文
共 21 条
[1]   Influence of field size on pupil diameter under photopic and mesopic light levels [J].
Atchison, David A. ;
Girgenti, Cameron C. ;
Campbell, Giles M. ;
Dodds, Jason P. ;
Byrnes, Tim M. ;
Zele, Andrew J. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2011, 94 (06) :545-548
[2]   The dependence of pupil size upon external light stimulus under static and variable conditions [J].
Crawford, BH .
PROCEEDINGS OF THE ROYAL SOCIETY SERIES B-BIOLOGICAL SCIENCES, 1936, 121 (822) :376-395
[3]   Constant luminance (cd•s/m2) versus constant retinal illuminance (Td•s) stimulation in flicker ERGs [J].
Davis, C. Quentin ;
Kraszewska, Olga ;
Manning, Colette .
DOCUMENTA OPHTHALMOLOGICA, 2017, 134 (02) :75-87
[4]   Effect of pupil size on residual wavefront aberration with transition zone after customized laser refractive surgery [J].
Fang, Lihua ;
Wang, Yan ;
He, Xingdao .
OPTICS EXPRESS, 2013, 21 (02) :1404-1416
[5]   Intensity of light and area of illuminated field as interacting factors in size of pupil [J].
Ferree, CE ;
Rand, G ;
Harris, ET .
JOURNAL OF EXPERIMENTAL PSYCHOLOGY, 1933, 16 :408-422
[6]   Introduction to grayscale calibration and related aspects of medical imaging grade liquid crystal displays [J].
Fetterly, Kenneth A. ;
Blume, Hartwig R. ;
Flynn, Michael J. ;
Samei, Ehsan .
JOURNAL OF DIGITAL IMAGING, 2008, 21 (02) :193-207
[7]   Progress in virtual reality and augmented reality based on holographic display [J].
He, Zehao ;
Sui, Xiaomeng ;
Jin, Guofan ;
Cao, Liangcai .
APPLIED OPTICS, 2019, 58 (05) :A74-A81
[8]   ARTIFICIAL PUPILS AND MAXWELLIAN VIEW [J].
JACOBS, RJ ;
BAILEY, IL ;
BULLIMORE, MA .
APPLIED OPTICS, 1992, 31 (19) :3668-3677
[9]   Effect of Pupil Size on Flicker ERGs Recorded With RETeval System: New Mydriasis-Free Full-Field ERG System [J].
Kato, Kumiko ;
Kondo, Mineo ;
Sugimoto, Masahiko ;
Ikesugi, Kengo ;
Matsubara, Hisashi .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (06) :3684-3690
[10]   Measuring the Task-Evoked Pupillary Response with a Remote Eye Tracker [J].
Klingner, Jeff ;
Kumar, Rakshit ;
Hanrahan, Pat .
PROCEEDINGS OF THE EYE TRACKING RESEARCH AND APPLICATIONS SYMPOSIUM (ETRA 2008), 2008, :69-72