Soft-Tissue Aberration Correction for Histotripsy

被引:26
作者
Macoskey, Jonathan J. [1 ]
Hall, Timothy L. [1 ]
Sukovich, Jonathan R. [1 ]
Choi, Sang Won [1 ]
Ives, Kimberly [1 ]
Johnsen, Eric [2 ]
Cain, Charles A. [1 ]
Xu, Zhen [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
Aberration correction (AC); cavitation; histotripsy; shockwaves; soft tissue; ultrasound; PULSED CAVITATIONAL ULTRASOUND; DROPLET VAPORIZATION; INTRINSIC THRESHOLD; SPECKLE BRIGHTNESS; BASIC PRINCIPLES; ABDOMINAL-WALL; TIME-REVERSAL; HUMAN SKULL; THERAPY; PHASE;
D O I
10.1109/TUFFC.2018.2872727
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Acoustic aberrations caused by natural heterogeneities of biological soft tissue are a substantial problem for histotripsy, a therapeutic ultrasound technique that uses acoustic cavitation to mechanically fractionate and destroy unwanted target tissue without damaging surrounding tissue. These aberrations, primarily caused by sound speed variations, result in severe defocusing of histotripsy pulses, thereby decreasing treatment efficacy. The gold standard for aberration correction (AC) is to place a hydrophone at the desired focal location to directly measure phase aberrations, which is a method that is infeasible in vivo. We hypothesized that the acoustic cavitation emission (ACE) shockwaves from the initial expansion of inertially cavitating microbubbles generated by histotripsy can be used as a point source for AC. In this study, a 500-kHz, 112-element histotripsy phased array capable of transmitting and receiving ultrasound on all channels was used to acquire ACE shockwaves. These shockwaves were first characterized optically and acoustically. It was found that the shockwave pressure increases significantly as the source changes from a single bubble to a dense cavitation cloud. The first arrival of the shockwave received by the histotripsy array was from the outer-most cavitation bubbles located closest to the histotripsy array. Hydrophone and ACE AC methods were then tested on ex vivo porcine abdominal tissue samples. Without AC, the focal pressure is reduced by 49.7% through the abdominal tissue. The hydrophone AC approach recovered 55.5% of the lost pressure. Using the ACE AC method, over 20% of the lost pressure was recovered, and the array power required to induce cavitation was reduced by approximately 31.5% compared to without AC. These results supported our hypothesis that the ACE shockwaves coupled with a histotripsy array with transmit and receive capability can be used for AC for histotripsy through soft tissue.
引用
收藏
页码:2073 / 2085
页数:13
相关论文
共 54 条
[1]  
[Anonymous], 2013, THESIS
[2]   GAUGING THE LIKELIHOOD OF CAVITATION FROM SHORT-PULSE, LOW-DUTY CYCLE DIAGNOSTIC ULTRASOUND [J].
APFEL, RE ;
HOLLAND, CK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :179-185
[3]   Experimental demonstration of noninvasive transskull adaptive focusing based on prior computed tomography scans [J].
Aubry, JF ;
Tanter, M ;
Pernot, M ;
Thomas, JL ;
Fink, M .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01) :84-93
[4]  
Duck F.A., 1990, PHYS PROPERTIES TISS, P73, DOI [10.1016/b978-0-12-222800-1.50008-5, DOI 10.1016/B978-0-12-222800-1.50008-5, 10.1016/B978-0-12-222800-1.50008-5]
[5]   Removal of Residual Nuclei Following a Cavitation Event: A Parametric Study [J].
Duryea, Alexander P. ;
Tamaddoni, Hedieh A. ;
Cain, Charles A. ;
Roberts, William W. ;
Hall, Timothy L. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (09) :1605-1614
[6]   TIME-REVERSAL OF ULTRASONIC FIELDS .1. BASIC PRINCIPLES [J].
FINK, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (05) :555-566
[7]   PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - BASIC PRINCIPLES [J].
FLAX, SW ;
ODONNELL, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) :758-767
[8]   Parallel processing techniques for the speckle brightness phase aberration correction algorithm [J].
Freiburger, PD ;
Trahey, GE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (02) :431-444
[9]   ACOUSTICAL PROPERTIES OF HUMAN SKULL [J].
FRY, FJ ;
BARGER, JE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 63 (05) :1576-1590
[10]   Catheter Hydrophone Aberration Correction for Transcranial Histotripsy Treatment of Intracerebral Hemorrhage: Proof-of-Concept [J].
Gerhardson, Tyler ;
Sukovich, Jonathan R. ;
Pandey, Aditya S. ;
Hall, Timothy L. ;
Cain, Charles A. ;
Xu, Zhen .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (11) :1684-1697