Non-intrusive Load Monitoring in MVDC Shipboard Power Systems using Wavelet-Convolutional Neural Networks

被引:6
|
作者
Senemmar, Soroush [1 ]
Zhang, Jie [1 ]
机构
[1] Univ Texas Dallas, Richardson, TX 75080 USA
来源
2022 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC) | 2021年
关键词
Convolutional neural networks; discrete wavelet transform; medium voltage DC; non-intrusive load monitoring; shipboard power system; FAULT-DETECTION; IDENTIFICATION;
D O I
10.1109/TPEC54980.2022.9750745
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper develops a non-intrusive load monitoring (NILM) method in future shipboard power systems (SPS) using discrete wavelet transform-based convolutional neural networks (CNN). We have applied the proposed NILM method to a two-zone medium voltage direct current (MVDC) SPS, with multiple appliances in each zone such as pulsed load, radar load, motor load, and hotel load. The input to the proposed NILM model only includes the current signal of generators, which will be first processed by a discrete wavelet transform, to form a coefficient matrix that represents the status of all the appliances in each zone. Then, a CNN model is adopted to monitor the load in real time by solving a multi-class classification problem. Results show that the proposed wavelet-based CNN model for NILM could: (i) determine the status of all appliances with an overall accuracy of more than 97%, and (ii) monitor specific pulsed loads with an accuracy of more than 98%.
引用
收藏
页码:242 / 247
页数:6
相关论文
共 50 条
  • [41] Non-intrusive load monitoring for appliance status determination using feed-forward neural network
    Mohd Fazzil, Nurul Afiqah
    Ibrahim, Ahmad Asrul
    Shareef, Hussain
    Zulkifley, Mohd Asyraf
    Remli, Muhammad Akmal
    PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (04): : 27 - 32
  • [42] Home electrical signal disaggregation for non-intrusive load monitoring (NILM) systems
    Figueiredo, Marisa
    de Almeida, Ana
    Ribeiro, Bernardete
    NEUROCOMPUTING, 2012, 96 : 66 - 73
  • [43] Non-intrusive Load Monitoring Method Based on Multi-task Learning Convolutional Network
    Deng X.
    Chen Z.
    Yang K.
    Liu B.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (08): : 189 - 197
  • [44] Non-intrusive load monitoring by using active and reactive power in additive Factorial Hidden Markov Models
    Bonfigli, Roberto
    Principi, Emanuele
    Fagiani, Marco
    Severini, Marco
    Squartini, Stefano
    Piazza, Francesco
    APPLIED ENERGY, 2017, 208 : 1590 - 1607
  • [45] Non-Intrusive Load Monitoring System Based on Convolution Neural Network and Adaptive Linear Programming Boosting
    Min, Chao
    Wen, Guoquan
    Yang, Zhaozhong
    Li, Xiaogang
    Li, Binrui
    ENERGIES, 2019, 12 (15)
  • [46] A Wasserstein-based distributionally robust neural network for non-intrusive load monitoring
    Zhang, Qing
    Yan, Yi
    Kong, Fannie
    Chen, Shifei
    Yang, Linfeng
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [47] Fault Diagnostics in Shipboard Power Systems using Graph Neural Networks
    Jacob, Roshni Anna
    Senemmar, Soroush
    Zhang, Jie
    2021 IEEE 13TH INTERNATIONAL SYMPOSIUM ON DIAGNOSTICS FOR ELECTRICAL MACHINES, POWER ELECTRONICS AND DRIVES (SDEMPED), 2021, : 316 - 321
  • [48] A New Measurement Method for Power Signatures of Non-intrusive Demand Monitoring and Load Identification
    Chang, Hsueh-Hsien
    Chen, Kun-Long
    Tsai, Yuan-Pin
    Lee, Wei-Jen
    2011 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2011,
  • [49] Novel Fractal-Based Features for Low-Power Appliances in Non-Intrusive Load Monitoring
    Mughees, Anam
    Kamran, Muhammad
    CMC-COMPUTERS MATERIALS & CONTINUA, 2024, 80 (01): : 507 - 526
  • [50] Non-intrusive load monitoring using multi-label classification methods
    Li, Ding
    Dick, Scott
    ELECTRICAL ENGINEERING, 2021, 103 (01) : 607 - 619