The effects of vasoactive drugs on pulse pressure and stroke volume variation in postoperative ventilated patients

被引:62
作者
Hadian, Mehrnaz [1 ]
Severyn, Donald A. [2 ]
Pinsky, Michael R. [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Crit Care Med, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Med Ctr, Dept Cardiothorac Surg, Pittsburgh, PA 15261 USA
关键词
Arterial pulse contour; Minimally invasive; Functional hemodynamic monitoring; LiDCO; Vasopressor; Vasodilator; Inotrope; Hemodynamic monitoring; Pulse contour analysis; Vasomotor tone; GOAL-DIRECTED THERAPY; FLUID RESPONSIVENESS; TIDAL VOLUME; RESPIRATORY CHANGES; CONTOUR ANALYSIS; PRELOAD RESPONSIVENESS; CONTROLLED-TRIAL; CARDIAC-SURGERY; MAJOR SURGERY; HOSPITAL STAY;
D O I
10.1016/j.jcrc.2010.08.018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Although pulse pressure variation (PPV) and stroke volume variation (SVV) during mechanical ventilation have been shown to predict preload responsiveness, the effect of vasoactive therapy on PPV and SVV is unknown. Methods: Pulse pressure variation and SVV were measured continuously in 15 cardiac surgery patients for the first 4 postoperative hours. Pulse pressure variation was directly measured from the arterial pressure waveform, and both PPV and SVV were also calculated by LiDCO Plus (LiDCO Ltd, Cambridge, United Kingdom) before and after volume challenges or changes in vasoactive drug infusions done to sustain cardiovascular stability. Results: Seventy-one paired events were studied (38 vasodilator, 10 vasoconstrictor, 14 inotropes, and 9 volume challenges). The difference between the measured and LiDCO-calculated PPV was 1% +/- 7% (1.96 SD, 95% confidence interval, r(2) = 0.8). Volume challenge decreased both PPV and SVV (15% to 10%, P < .05 and 13% to 9%, P = .09, respectively). Vasodilator therapy increased PPV and SVV (13% to 17% and 9% to 15%, respectively, P < .001), whereas increasing inotropes or vasoconstrictors did not alter PPV or SVV. The PPV/SVV ratio was unaffected by treatments. Conclusion: Volume loading decreased PPV and SVV; and vasodilators increased both, consistent with their known cardiovascular effects. Thus, SVV and PPV can be used to drive fluid resuscitation algorithms in the setting of changing vasoactive drug therapy. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:328.e1 / 328.e8
页数:8
相关论文
共 27 条
[1]  
Berkenstadt H, 2001, ANESTH ANALG, V92, P984
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   The influence of tidal volume on the dynamic variables of fluid responsiveness in critically III patients [J].
Charron, C ;
Fessenmeyer, C ;
Cosson, C ;
Mazoit, JX ;
Hebert, JL ;
Benhamou, D ;
Edouard, AR .
ANESTHESIA AND ANALGESIA, 2006, 102 (05) :1511-1517
[4]   Pulse pressure variations to predict fluid responsiveness: influence of tidal volume [J].
De Backer, D ;
Heenen, S ;
Piagnerelli, M ;
Koch, M ;
Vincent, JL .
INTENSIVE CARE MEDICINE, 2005, 31 (04) :517-523
[5]   Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock [J].
Feissel, M ;
Michard, F ;
Mangin, I ;
Ruyer, O ;
Faller, JP ;
Teboul, JL .
CHEST, 2001, 119 (03) :867-873
[6]   Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery [J].
Gan, TJ ;
Soppitt, A ;
Maroof, M ;
El-Moalem, H ;
Robertson, KM ;
Moretti, E ;
Dwane, P ;
Glass, PSA .
ANESTHESIOLOGY, 2002, 97 (04) :820-826
[7]   Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting [J].
Hofer, CK ;
Müller, SM ;
Furrer, L ;
Klaghofer, R ;
Genoni, M ;
Zollinger, A .
CHEST, 2005, 128 (02) :848-854
[8]   Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation [J].
Kim, Hyung Kook ;
Pinsky, Michael R. .
CRITICAL CARE MEDICINE, 2008, 36 (10) :2858-2862
[9]   Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects [J].
Kumar, A ;
Anel, R ;
Bunnell, E ;
Habet, K ;
Zanotti, S ;
Marshall, S ;
Neumann, A ;
Ali, A ;
Cheang, M ;
Kavinsky, C ;
Parrillo, JE .
CRITICAL CARE MEDICINE, 2004, 32 (03) :691-699
[10]   Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial [J].
Lopes, Marcel R. ;
Oliveira, Marcos A. ;
Pereira, Vanessa Oliveira S. ;
Lemos, Ivaneide Paula B. ;
Auler, Jose Otavio C., Jr. ;
Michard, Frederick .
CRITICAL CARE, 2007, 11 (05)