European Concerted Action on Anticoagulation. A multicentre calibration study of WHO international reference preparations for thromboplastin, rabbit (RBT/90) and human (rTF/95)

被引:9
作者
Poller, L [1 ]
Keown, M
Chauhan, N
van den Besselaar, AMHP
Tripodi, A
Shiach, C
Jespersen, J
机构
[1] Univ Manchester, Fac Life Sci, ECAA Cent Facil, Manchester M13 9PT, Lancs, England
[2] Leiden Univ, Med Ctr, Haemostasis & Thrombosis Res Ctr, NL-2300 RC Leiden, Netherlands
[3] Univ Milan, Maggiore Hosp, IRCCS, Haemophilia & Thrombosis Ctr, I-20122 Milan, Italy
[4] Manchester Royal Infirm, Dept Haematol, Manchester M13 9WL, Lancs, England
[5] Univ So Denmark, Dept Thrombosis Res, DK-6700 Esbjerg, Denmark
[6] Ribe Cty Hosp, Dept Clin Biochem, DK-6700 Esbjerg, Denmark
关键词
D O I
10.1136/jcp.2004.019810
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
A 10 centre calibration was performed after six years to determine the international sensitivity index (ISI) of rTF/95 relative to RBT/90, and to assess any international normalised ratio (INR) bias compared with the original multicentre calibration. After exclusion of one outlying centre, the follow up calibration gave a mean ISI for rTF/95 of 0.99, which although a small difference, is significantly greater than the mean ISI of 0.94 obtained previously. The change in ISI for international reference preparation (IRP) rTF/95 relative to RBT/90 would lead to a slight bias in INR for human compared with rabbit thromboplastins. At a theoretical INR of 3.0, the INR bias is 6.0%, and this is below the accepted 10% level of clinical relevance. Ongoing stability monitoring of World Health Organisation thromboplastin IRP is advised.
引用
收藏
页码:667 / 669
页数:3
相关论文
共 10 条
[1]  
[Anonymous], 1984, THROMBOPLASTIN CALIB
[2]   The effect of sample size on fresh plasma thromboplastin ISI determination [J].
Poller, L ;
van den Besselaar, AMHP ;
Jespersen, J ;
Tripodi, A ;
Houghton, D .
BRITISH JOURNAL OF HAEMATOLOGY, 1999, 105 (03) :655-663
[3]   European Concerted Action on Anticoagulation (ECAA): multicentre international sensitivity index calibration of two types of point-of-care prothrombin time monitor systems [J].
Poller, L ;
Keown, M ;
Chauhan, N ;
van den Besselaar, AMHP ;
Tripodi, A ;
Jespersen, J ;
Shiach, C ;
Horellou, MH ;
Dias, D ;
Egberg, N ;
Iriarte, JA ;
Otridge, B .
BRITISH JOURNAL OF HAEMATOLOGY, 2002, 116 (04) :844-850
[4]  
Poller L, 2002, THROMB HAEMOSTASIS, V87, P859
[5]  
POLLER L, 1994, THROMB HAEMOSTASIS, V72, P682
[6]  
Tripodi A, 1998, THROMB HAEMOSTASIS, V79, P439
[7]  
TRIPODI A, 1995, THROMB HAEMOSTASIS, V74, P1368
[8]  
van den Besselaar AMHP, 2002, THROMB HAEMOSTASIS, V88, P459
[9]  
VANDENBESSELAAR AMHP, 1993, THROMB HAEMOSTASIS, V70, P794
[10]  
WHO Expert Committee on Biological Standardization, 1999, WHO TECH REP SER, P64