Dual-phase Au-Pt alloys free from magnetic susceptibility artifacts in magnetic resonance imaging

被引:6
作者
Nakai, Ryusuke [1 ]
Goto, Kenji [2 ]
Shima, Kunihiro [3 ]
Kodama, Tomonobu [4 ]
Iwata, Hiroo [5 ]
机构
[1] Kyoto Univ, Kokoro Res Ctr, Kyoto, Japan
[2] Tanaka Kikinzoku Kogyo KK, Isehara Tech Ctr, Kogyo, Japan
[3] Tanaka Kikinzoku Kogyo KK, Dept Mat Dev, Kogyo, Japan
[4] Jikei Univ, Sch Med, Dept Neurosurg, Tokyo, Japan
[5] Kyoto Univ, Grad Sch Med, Kyoto, Japan
关键词
Magnetic resonance imaging; Magnetic susceptibility artifact; Au-Pt dual-phase alloys; IN-VITRO EVALUATION; DNA HYBRIDIZATION; MRI; NANOPARTICLES; SIMULATION; CELLS; 1ST;
D O I
10.1016/j.mri.2021.10.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Magnetic resonance imaging (MRI) devices are frequently used in image-based diagnosis. In the case of large artifacts, which are generated in magnetic resonance (MR) images when magnetic materials, such as metals, are present in the body, these devices are less useful. This study aimed to develop a dual-phase Au-Pt alloy that does not generate artifacts in MR images and has high workability to prepare medical devices. Materials and methods: A processing method to produce a dual-phase Au-Pt alloy was established, and the magnetic susceptibility and artifacts of different alloy compositions were determined using a SQUID (super-conducting quantum interference device) flux meter and a 1.5 T-MRI system. The crystallographic phases of the prepared alloy samples were identified using X-ray diffraction. Sample cross-sections were observed using a metallurgical microscope. Furthermore, a thinning test was conducted to examine alloy workability. Results: Dual-phase Au-Pt alloys Au70Pt30 and Au67Pt33-the former heat-treated at 800 and 850 degrees C and the latter heat-treated at 900 degrees C-generated minimal artifacts when imaged in a 1.5 T-MRI system. Their volume magnetic susceptibility increased as the heat-treatment temperature decreased. The alloy surfaces were observed to be uniform. Moreover, the workability of the dual-phase alloy was considerably better than that of the single-phase alloy. Conclusion: Volume magnetic susceptibility could be controlled by changing the composition and processing temperature of the Au-Pt alloys. Dual-phase Au-Pt alloys those do not generate magnetic susceptibility artifacts in MRI images and have good workability could be prepared. The alloys are expected to be used in the preparation of various implantable medical devices.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
[41]   Folic acid-functionalized gadolinium-loaded phase transition nanodroplets for dual-modal ultrasound/magnetic resonance imaging of hepatocellular carcinoma [J].
Maghsoudinia, Fatemeh ;
Tavakoli, Mohamad Bagher ;
Samani, Roghayeh Kamran ;
Hejazi, Seyed Hossein ;
Sobhani, Tayebe ;
Mehradnia, Fatemeh ;
Mehrgardi, Masoud A. .
TALANTA, 2021, 228
[42]   Comparing the Detectability of Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam Computed Tomography During Hepatic Arteriography With Conventional Contrast-Enhanced Magnetic Resonance Imaging [J].
Romaric Loffroy ;
MingDe Lin ;
Pramod Rao ;
Nikhil Bhagat ;
Niels Noordhoek ;
Alessandro Radaelli ;
Järl Blijd ;
Jean-François Geschwind .
CardioVascular and Interventional Radiology, 2012, 35 :97-104
[43]   Magnetically engineered Cd-free quantum dots as dual-modality probes for fluorescence/magnetic resonance imaging of tumors [J].
Ding, Ke ;
Jing, Lihong ;
Liu, Chunyan ;
Hou, Yi ;
Gao, Mingyuan .
BIOMATERIALS, 2014, 35 (05) :1608-1617
[44]   Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients [J].
Julius Traber ;
Lennart Wurche ;
Matthias A. Dieringer ;
Wolfgang Utz ;
Florian von Knobelsdorff-Brenkenhoff ;
Andreas Greiser ;
Ning Jin ;
Jeanette Schulz-Menger .
European Radiology, 2016, 26 :986-996
[45]   Predictive Value of Dual-phase 18F-FDG PET/CT in the Assessment of Neoadjuvant Chemotherapy Response in Patients with Locally Advanced Breast Cancer: A prospective Comparative Study with Dynamic Contrast-enhanced Magnetic Resonance Imaging [J].
Kupik, Osman ;
Tuncel, Murat ;
Kiratli, Pinar Ozgen ;
Akpinar, Meltem Gulsun ;
Altundag, Kadri ;
Demirkazik, Figen Basaran ;
Erbas, Belkis .
TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (04) :426-435
[46]   Clinical Evaluation of Left Ventricular Diastolic Function Using Phase-contrast Cine Cardiovascular Magnetic Resonance Imaging: A Comparison With Steady-state Free Precession Cine Cardiovascular Magnetic Resonance Imaging and Echocardiography [J].
Komi, Shotaro ;
Inoue, Yusuke ;
Hata, Hirofumi ;
Miyatake, Hiroki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) :56-63
[47]   Enhanced gray and white matter contrast of phase susceptibility-weighted images in ultra-high-field magnetic resonance imaging [J].
Abduljalil, AM ;
Schmalbrock, P ;
Novak, V ;
Chakeres, DW .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (03) :284-290
[48]   Variability and accuracy of different software packages for dynamic susceptibility contrast magnetic resonance imaging for distinguishing glioblastoma progression from pseudoprogression [J].
Kelm, Zachary S. ;
Korfiatis, Panagiotis D. ;
Lingineni, Ravi K. ;
Daniels, John R. ;
Buckner, Jan C. ;
Lachance, Daniel H. ;
Parney, Ian F. ;
Carter, Rickey E. ;
Erickson, Bradley J. .
JOURNAL OF MEDICAL IMAGING, 2015, 2 (02)
[49]   Improved elimination of phase effects from background field inhomogeneities for susceptibility weighted imaging at high magnetic field strengths [J].
Rauscher, Alexander ;
Barth, Markus ;
Herrmann, Karl-Heinz ;
Witoszynskyj, Stephan ;
Deistung, Andreas ;
Reichenbach, Jueergen R. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (08) :1145-1151
[50]   SIMULATION OF SUSCEPTIBILITY ARTIFACTS IN 2D AND 3D FOURIER-TRANSFORM SPIN-ECHO AND GRADIENT-ECHO MAGNETIC-RESONANCE-IMAGING [J].
BAKKER, CJG ;
BHAGWANDIEN, R ;
MOERLAND, MA ;
RAMOS, LMP .
MAGNETIC RESONANCE IMAGING, 1994, 12 (05) :767-774