Dual-phase Au-Pt alloys free from magnetic susceptibility artifacts in magnetic resonance imaging

被引:6
作者
Nakai, Ryusuke [1 ]
Goto, Kenji [2 ]
Shima, Kunihiro [3 ]
Kodama, Tomonobu [4 ]
Iwata, Hiroo [5 ]
机构
[1] Kyoto Univ, Kokoro Res Ctr, Kyoto, Japan
[2] Tanaka Kikinzoku Kogyo KK, Isehara Tech Ctr, Kogyo, Japan
[3] Tanaka Kikinzoku Kogyo KK, Dept Mat Dev, Kogyo, Japan
[4] Jikei Univ, Sch Med, Dept Neurosurg, Tokyo, Japan
[5] Kyoto Univ, Grad Sch Med, Kyoto, Japan
关键词
Magnetic resonance imaging; Magnetic susceptibility artifact; Au-Pt dual-phase alloys; IN-VITRO EVALUATION; DNA HYBRIDIZATION; MRI; NANOPARTICLES; SIMULATION; CELLS; 1ST;
D O I
10.1016/j.mri.2021.10.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Magnetic resonance imaging (MRI) devices are frequently used in image-based diagnosis. In the case of large artifacts, which are generated in magnetic resonance (MR) images when magnetic materials, such as metals, are present in the body, these devices are less useful. This study aimed to develop a dual-phase Au-Pt alloy that does not generate artifacts in MR images and has high workability to prepare medical devices. Materials and methods: A processing method to produce a dual-phase Au-Pt alloy was established, and the magnetic susceptibility and artifacts of different alloy compositions were determined using a SQUID (super-conducting quantum interference device) flux meter and a 1.5 T-MRI system. The crystallographic phases of the prepared alloy samples were identified using X-ray diffraction. Sample cross-sections were observed using a metallurgical microscope. Furthermore, a thinning test was conducted to examine alloy workability. Results: Dual-phase Au-Pt alloys Au70Pt30 and Au67Pt33-the former heat-treated at 800 and 850 degrees C and the latter heat-treated at 900 degrees C-generated minimal artifacts when imaged in a 1.5 T-MRI system. Their volume magnetic susceptibility increased as the heat-treatment temperature decreased. The alloy surfaces were observed to be uniform. Moreover, the workability of the dual-phase alloy was considerably better than that of the single-phase alloy. Conclusion: Volume magnetic susceptibility could be controlled by changing the composition and processing temperature of the Au-Pt alloys. Dual-phase Au-Pt alloys those do not generate magnetic susceptibility artifacts in MRI images and have good workability could be prepared. The alloys are expected to be used in the preparation of various implantable medical devices.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
[31]   Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients [J].
Traber, Julius ;
Wurche, Lennart ;
Dieringer, Matthias A. ;
Utz, Wolfgang ;
von Knobelsdorff-Brenkenhoff, Florian ;
Greiser, Andreas ;
Jin, Ning ;
Schulz-Menger, Jeanette .
EUROPEAN RADIOLOGY, 2016, 26 (04) :986-996
[32]   Fabricating Dual-Functional Plasmonic-Magnetic Au@MgFe2O4 Nanohybrids for Photothermal Therapy and Magnetic Resonance Imaging [J].
Qiu, Enhui ;
Chen, Xiaofang ;
Yang, Da-Peng ;
Regulacio, Michelle D. ;
Ramos, Rufus Mart Ceasar R. ;
Luo, Zheng ;
Wu, Yun-Long ;
Lin, Ming ;
Li, Zibiao ;
Loh, Xian Jun ;
Ye, Enyi .
ACS OMEGA, 2022, 7 (02) :2031-2040
[33]   Distinguishing Benign From Malignant Soft Tissue Tumors By Dynamic Susceptibility Contrast Magnetic Resonance Imaging [J].
Hori, Masaaki .
ACADEMIC RADIOLOGY, 2020, 27 (03) :361-362
[34]   A dual center and dual vendor comparison study of automated perfusion-weighted phase-resolved functional lung magnetic resonance imaging with dynamic contrast-enhanced magnetic resonance imaging in patients with cystic fibrosis [J].
Behrendt, Lea ;
Smith, Laurie J. ;
Voskrebenzev, Andreas ;
Klimes, Filip ;
Kaireit, Till F. ;
Poehler, Gesa H. ;
Kern, Agilo L. ;
Gonzalez, Cristian Crisosto ;
Dittrich, Anna-Maria ;
Marshall, Helen ;
Schuetz, Katharina ;
Hughes, Paul J. C. ;
Ciet, Pierluigi ;
Tiddens, Harm A. W. M. ;
Wild, Jim M. ;
Vogel-Claussen, Jens .
PULMONARY CIRCULATION, 2022, 12 (02)
[35]   Background-free dual-mode optical and 13C magnetic resonance imaging in diamond particles [J].
Lv, Xudong ;
Walton, Jeffrey H. ;
Druga, Emanuel ;
Wang, Fei ;
Aguilar, Alessandra ;
McKnelly, Tommy ;
Nazaryan, Raffi ;
Liu, Fanglin Linda ;
Wu, Lan ;
Shenderova, Olga ;
Vigneron, Daniel B. ;
Meriles, Carlos A. ;
Reimer, Jeffrey A. ;
Pines, Alexander ;
Ajoy, Ashok .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2021, 118 (21)
[36]   Laser-synthesized ligand-free Au nanoparticles for contrast agent applications in computed tomography and magnetic resonance imaging [J].
Simao, Teresa ;
Chevallier, Pascale ;
Lagueux, Jean ;
Cote, Marie-France ;
Rehbock, Christoph ;
Barcikowski, Stephan ;
Fortin, Marc-Andre ;
Guay, Daniel .
JOURNAL OF MATERIALS CHEMISTRY B, 2016, 4 (39) :6413-6427
[37]   Modeling susceptibility difference artifacts produced by metallic implants in Magnetic Resonance Imaging with point-based thin-plate spline image registration [J].
Pauchard, Y ;
Smith, MR ;
Mintchev, MP .
PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 :1766-1769
[38]   Signal changes in cortical laminar necrosis-evidence from susceptibility-weighted magnetic resonance imaging [J].
Kesavadas, Chandrasekharan ;
Santhosh, Kannath ;
Thomas, Bejoy ;
Gupta, Arun Kumar ;
Kapilamoorthy, Tirur Raman ;
Bodhey, Narendra ;
Pendharker, Hima ;
Patro, Satyanarayana .
NEURORADIOLOGY, 2009, 51 (05) :293-298
[39]   Carrier-free nanoparticles for cancer theranostics with dual-mode magnetic resonance imaging/fluorescence imaging and combination photothermal and chemodynamic therapy [J].
Ding, Yuhan ;
Deng, Caiting ;
Yang, Yuchen ;
Zhang, Jingjing ;
Liu, Wen ;
Aras, Omer ;
An, Feifei ;
Liu, Jun ;
Chai, Yichao .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2025, 671
[40]   Comparing the Detectability of Hepatocellular Carcinoma by C-Arm Dual-Phase Cone-Beam Computed Tomography During Hepatic Arteriography With Conventional Contrast-Enhanced Magnetic Resonance Imaging [J].
Loffroy, Romaric ;
Lin, MingDe ;
Rao, Pramod ;
Bhagat, Nikhil ;
Noordhoek, Niels ;
Radaelli, Alessandro ;
Blijd, Jarl ;
Geschwind, Jean-Francois .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 35 (01) :97-104