Dual-phase Au-Pt alloys free from magnetic susceptibility artifacts in magnetic resonance imaging

被引:6
作者
Nakai, Ryusuke [1 ]
Goto, Kenji [2 ]
Shima, Kunihiro [3 ]
Kodama, Tomonobu [4 ]
Iwata, Hiroo [5 ]
机构
[1] Kyoto Univ, Kokoro Res Ctr, Kyoto, Japan
[2] Tanaka Kikinzoku Kogyo KK, Isehara Tech Ctr, Kogyo, Japan
[3] Tanaka Kikinzoku Kogyo KK, Dept Mat Dev, Kogyo, Japan
[4] Jikei Univ, Sch Med, Dept Neurosurg, Tokyo, Japan
[5] Kyoto Univ, Grad Sch Med, Kyoto, Japan
关键词
Magnetic resonance imaging; Magnetic susceptibility artifact; Au-Pt dual-phase alloys; IN-VITRO EVALUATION; DNA HYBRIDIZATION; MRI; NANOPARTICLES; SIMULATION; CELLS; 1ST;
D O I
10.1016/j.mri.2021.10.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Magnetic resonance imaging (MRI) devices are frequently used in image-based diagnosis. In the case of large artifacts, which are generated in magnetic resonance (MR) images when magnetic materials, such as metals, are present in the body, these devices are less useful. This study aimed to develop a dual-phase Au-Pt alloy that does not generate artifacts in MR images and has high workability to prepare medical devices. Materials and methods: A processing method to produce a dual-phase Au-Pt alloy was established, and the magnetic susceptibility and artifacts of different alloy compositions were determined using a SQUID (super-conducting quantum interference device) flux meter and a 1.5 T-MRI system. The crystallographic phases of the prepared alloy samples were identified using X-ray diffraction. Sample cross-sections were observed using a metallurgical microscope. Furthermore, a thinning test was conducted to examine alloy workability. Results: Dual-phase Au-Pt alloys Au70Pt30 and Au67Pt33-the former heat-treated at 800 and 850 degrees C and the latter heat-treated at 900 degrees C-generated minimal artifacts when imaged in a 1.5 T-MRI system. Their volume magnetic susceptibility increased as the heat-treatment temperature decreased. The alloy surfaces were observed to be uniform. Moreover, the workability of the dual-phase alloy was considerably better than that of the single-phase alloy. Conclusion: Volume magnetic susceptibility could be controlled by changing the composition and processing temperature of the Au-Pt alloys. Dual-phase Au-Pt alloys those do not generate magnetic susceptibility artifacts in MRI images and have good workability could be prepared. The alloys are expected to be used in the preparation of various implantable medical devices.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
  • [21] A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging
    Kajan, Zahra Dalili
    Khademi, Jalil
    Alizadeh, Ahmad
    Hemmaty, Yasamin Babaei
    Roushan, Zahra Atrkar
    IMAGING SCIENCE IN DENTISTRY, 2015, 45 (03) : 159 - 168
  • [22] Quantification of metal-induced susceptibility artifacts associated with ultrahigh-field magnetic resonance imaging of spinal implants
    Chiba, Yusuke
    Murakami, Hideki
    Sasaki, Makoto
    Endo, Hirooki
    Yamabe, Daisuke
    Kinno, Daichi
    Doita, Minoru
    JOR SPINE, 2019, 2 (03):
  • [23] Comparison of the impact of rectal susceptibility artifacts in prostate magnetic resonance imaging on subjective evaluation and deep learning: a two-center retrospective study
    Wang, Zheng
    Lu, Peng
    Liu, Song
    Fu, Chengzhi
    Ye, Yong
    Yu, Chengxin
    Hu, Lei
    BMC MEDICAL IMAGING, 2025, 25 (01):
  • [24] Magnetic resonance imaging outcomes from a phase III trial of teriflunomide
    Wolinsky, Jerry S.
    Narayana, Ponnada A.
    Nelson, Flavia
    Datta, Sushmita
    O'Connor, Paul
    Confavreux, Christian
    Comi, Giancarlo
    Kappos, Ludwig
    Olsson, Tomas P.
    Truffinet, Philippe
    Wang, Lin
    Miller, Aaron
    Freedman, Mark S.
    MULTIPLE SCLEROSIS JOURNAL, 2013, 19 (10) : 1310 - 1319
  • [25] Multifunctional gadofulleride nanoprobe for magnetic resonance imaging/fluorescent dual modality molecular imaging and free radical scavenging
    Zheng, Jun-peng
    Zhen, Ming-Ming
    Ge, Jie-Chao
    Liu, Qiao-Ling
    Jiang, Feng
    Shu, Chun-Ying
    Alhadlaq, Hisham A.
    Wang, Chun-Ru
    CARBON, 2013, 65 : 175 - 180
  • [26] Magnetic targeting core/shell Fe3O4/Au nanoparticles for magnetic resonance/photoacoustic dual-modal imaging
    Kang, Ning
    Xu, Dan
    Han, Yu
    Lv, Xiaolin
    Chen, Zhiwei
    Zhou, Tiantian
    Ren, Lei
    Zhou, Xi
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 545 - 549
  • [27] Comparison of medetomidine, thiopental and ketamine/midazolam anesthesia in chick embryos for in ovo Magnetic Resonance Imaging free of motion artifacts
    Waschkies, Conny
    Nicholls, Flora
    Buschmann, Johanna
    SCIENTIFIC REPORTS, 2015, 5
  • [28] Iron-Containing Abdominal Pathologies: Exploiting Magnetic Susceptibility Artifact on Dual-Echo Gradient-Echo Magnetic Resonance Imaging
    Thomas, Aaron J.
    Morani, Ajaykumar C.
    Liu, Peter S.
    Weadock, William J.
    Hussain, Hero K.
    Elsayes, Khaled M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (02) : 165 - 175
  • [29] Study of dual-phase functionalisation of NiCoFeCr-Alx multicomponent alloys for the enhancement of magnetic properties and magneto-caloric effect
    Quintana-Nedelcos, A.
    Leong, Z.
    Morley, N. A.
    MATERIALS TODAY ENERGY, 2021, 20
  • [30] Real-time phase contrast magnetic resonance imaging for assessment of haemodynamics: from phantom to patients
    Traber, Julius
    Wurche, Lennart
    Dieringer, Matthias A.
    Utz, Wolfgang
    von Knobelsdorff-Brenkenhoff, Florian
    Greiser, Andreas
    Jin, Ning
    Schulz-Menger, Jeanette
    EUROPEAN RADIOLOGY, 2016, 26 (04) : 986 - 996