Purpose: Magnetic resonance imaging (MRI) devices are frequently used in image-based diagnosis. In the case of large artifacts, which are generated in magnetic resonance (MR) images when magnetic materials, such as metals, are present in the body, these devices are less useful. This study aimed to develop a dual-phase Au-Pt alloy that does not generate artifacts in MR images and has high workability to prepare medical devices. Materials and methods: A processing method to produce a dual-phase Au-Pt alloy was established, and the magnetic susceptibility and artifacts of different alloy compositions were determined using a SQUID (super-conducting quantum interference device) flux meter and a 1.5 T-MRI system. The crystallographic phases of the prepared alloy samples were identified using X-ray diffraction. Sample cross-sections were observed using a metallurgical microscope. Furthermore, a thinning test was conducted to examine alloy workability. Results: Dual-phase Au-Pt alloys Au70Pt30 and Au67Pt33-the former heat-treated at 800 and 850 degrees C and the latter heat-treated at 900 degrees C-generated minimal artifacts when imaged in a 1.5 T-MRI system. Their volume magnetic susceptibility increased as the heat-treatment temperature decreased. The alloy surfaces were observed to be uniform. Moreover, the workability of the dual-phase alloy was considerably better than that of the single-phase alloy. Conclusion: Volume magnetic susceptibility could be controlled by changing the composition and processing temperature of the Au-Pt alloys. Dual-phase Au-Pt alloys those do not generate magnetic susceptibility artifacts in MRI images and have good workability could be prepared. The alloys are expected to be used in the preparation of various implantable medical devices.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
[21]   A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging [J].
Kajan, Zahra Dalili ;
Khademi, Jalil ;
Alizadeh, Ahmad ;
Hemmaty, Yasamin Babaei ;
Roushan, Zahra Atrkar .
IMAGING SCIENCE IN DENTISTRY, 2015, 45 (03) :159-168
[22]   Quantification of metal-induced susceptibility artifacts associated with ultrahigh-field magnetic resonance imaging of spinal implants [J].
Chiba, Yusuke ;
Murakami, Hideki ;
Sasaki, Makoto ;
Endo, Hirooki ;
Yamabe, Daisuke ;
Kinno, Daichi ;
Doita, Minoru .
JOR SPINE, 2019, 2 (03)
[23]   Comparison of the impact of rectal susceptibility artifacts in prostate magnetic resonance imaging on subjective evaluation and deep learning: a two-center retrospective study [J].
Wang, Zheng ;
Lu, Peng ;
Liu, Song ;
Fu, Chengzhi ;
Ye, Yong ;
Yu, Chengxin ;
Hu, Lei .
BMC MEDICAL IMAGING, 2025, 25 (01)
[24]   Magnetic resonance imaging outcomes from a phase III trial of teriflunomide [J].
Wolinsky, Jerry S. ;
Narayana, Ponnada A. ;
Nelson, Flavia ;
Datta, Sushmita ;
O'Connor, Paul ;
Confavreux, Christian ;
Comi, Giancarlo ;
Kappos, Ludwig ;
Olsson, Tomas P. ;
Truffinet, Philippe ;
Wang, Lin ;
Miller, Aaron ;
Freedman, Mark S. .
MULTIPLE SCLEROSIS JOURNAL, 2013, 19 (10) :1310-1319
[25]   Multifunctional gadofulleride nanoprobe for magnetic resonance imaging/fluorescent dual modality molecular imaging and free radical scavenging [J].
Zheng, Jun-peng ;
Zhen, Ming-Ming ;
Ge, Jie-Chao ;
Liu, Qiao-Ling ;
Jiang, Feng ;
Shu, Chun-Ying ;
Alhadlaq, Hisham A. ;
Wang, Chun-Ru .
CARBON, 2013, 65 :175-180
[26]   Magnetic targeting core/shell Fe3O4/Au nanoparticles for magnetic resonance/photoacoustic dual-modal imaging [J].
Kang, Ning ;
Xu, Dan ;
Han, Yu ;
Lv, Xiaolin ;
Chen, Zhiwei ;
Zhou, Tiantian ;
Ren, Lei ;
Zhou, Xi .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 :545-549
[27]   Comparison of medetomidine, thiopental and ketamine/midazolam anesthesia in chick embryos for in ovo Magnetic Resonance Imaging free of motion artifacts [J].
Waschkies, Conny ;
Nicholls, Flora ;
Buschmann, Johanna .
SCIENTIFIC REPORTS, 2015, 5
[28]   Iron-Containing Abdominal Pathologies: Exploiting Magnetic Susceptibility Artifact on Dual-Echo Gradient-Echo Magnetic Resonance Imaging [J].
Thomas, Aaron J. ;
Morani, Ajaykumar C. ;
Liu, Peter S. ;
Weadock, William J. ;
Hussain, Hero K. ;
Elsayes, Khaled M. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (02) :165-175
[29]   Artifacts in magnetic resonance imaging of the head and neck: Unwanted effects caused by implant-supported restorations fabricated with different alloys [J].
Bohner, Lauren ;
Dirksen, Dieter ;
Hanisch, Marcel ;
Sesma, Newton ;
Kleinheinz, Johannes ;
Meier, Norbert .
JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (06) :1574-1579
[30]   Study of dual-phase functionalisation of NiCoFeCr-Alx multicomponent alloys for the enhancement of magnetic properties and magneto-caloric effect [J].
Quintana-Nedelcos, A. ;
Leong, Z. ;
Morley, N. A. .
MATERIALS TODAY ENERGY, 2021, 20