Dual-phase Au-Pt alloys free from magnetic susceptibility artifacts in magnetic resonance imaging

被引:6
|
作者
Nakai, Ryusuke [1 ]
Goto, Kenji [2 ]
Shima, Kunihiro [3 ]
Kodama, Tomonobu [4 ]
Iwata, Hiroo [5 ]
机构
[1] Kyoto Univ, Kokoro Res Ctr, Kyoto, Japan
[2] Tanaka Kikinzoku Kogyo KK, Isehara Tech Ctr, Kogyo, Japan
[3] Tanaka Kikinzoku Kogyo KK, Dept Mat Dev, Kogyo, Japan
[4] Jikei Univ, Sch Med, Dept Neurosurg, Tokyo, Japan
[5] Kyoto Univ, Grad Sch Med, Kyoto, Japan
关键词
Magnetic resonance imaging; Magnetic susceptibility artifact; Au-Pt dual-phase alloys; IN-VITRO EVALUATION; DNA HYBRIDIZATION; MRI; NANOPARTICLES; SIMULATION; CELLS; 1ST;
D O I
10.1016/j.mri.2021.10.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Magnetic resonance imaging (MRI) devices are frequently used in image-based diagnosis. In the case of large artifacts, which are generated in magnetic resonance (MR) images when magnetic materials, such as metals, are present in the body, these devices are less useful. This study aimed to develop a dual-phase Au-Pt alloy that does not generate artifacts in MR images and has high workability to prepare medical devices. Materials and methods: A processing method to produce a dual-phase Au-Pt alloy was established, and the magnetic susceptibility and artifacts of different alloy compositions were determined using a SQUID (super-conducting quantum interference device) flux meter and a 1.5 T-MRI system. The crystallographic phases of the prepared alloy samples were identified using X-ray diffraction. Sample cross-sections were observed using a metallurgical microscope. Furthermore, a thinning test was conducted to examine alloy workability. Results: Dual-phase Au-Pt alloys Au70Pt30 and Au67Pt33-the former heat-treated at 800 and 850 degrees C and the latter heat-treated at 900 degrees C-generated minimal artifacts when imaged in a 1.5 T-MRI system. Their volume magnetic susceptibility increased as the heat-treatment temperature decreased. The alloy surfaces were observed to be uniform. Moreover, the workability of the dual-phase alloy was considerably better than that of the single-phase alloy. Conclusion: Volume magnetic susceptibility could be controlled by changing the composition and processing temperature of the Au-Pt alloys. Dual-phase Au-Pt alloys those do not generate magnetic susceptibility artifacts in MRI images and have good workability could be prepared. The alloys are expected to be used in the preparation of various implantable medical devices.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
  • [1] Preparation of an Au-Pt alloy free from artifacts in magnetic resonance imaging
    Kodama, Tomonobu
    Nakai, Ryusuke
    Goto, Kenji
    Shima, Kunihiro
    Iwata, Hiroo
    MAGNETIC RESONANCE IMAGING, 2017, 44 : 38 - 45
  • [2] Effects of cold plastic deformation on microstructure and magnetic susceptibility of Au-Pt alloys
    Yan, Yi
    Luo, Dong
    Wu, Wei
    Yu, Yuanyang
    Huo, Yancong
    Chen, Qiao
    Lu, Jianmin
    Song, Wei
    Xiong, Zhi
    Fu, Quan
    Liu, Yi
    Lu, Yanli
    Hu, Rui
    Zhang, Butian
    Wang, Shun
    JOURNAL OF ALLOYS AND COMPOUNDS, 2024, 1007
  • [3] Artifacts from dental casting alloys in magnetic resonance imaging
    Shafiei, F
    Honda, E
    Takahashi, H
    Sasaki, T
    JOURNAL OF DENTAL RESEARCH, 2003, 82 (08) : 602 - 606
  • [4] Theoretical Calculations and Experimental Measurements on the Two-Component Au-Pt Alloys with Ultralow Magnetic Susceptibility
    Lou, Ao
    Yu, Yuanyang
    Zhang, Butian
    Liu, Yi
    Fu, Quan
    Zhang, Jiankang
    Fu, Hua-Hua
    Wang, Shun
    Zhou, Ze-Bing
    PHYSICAL REVIEW APPLIED, 2023, 19 (03)
  • [5] Magnetic susceptibility artifacts in Magnetic Resonance Imaging: Calculation of the magnetic field disturbances
    Balac, S
    Caloz, G
    IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (03) : 1645 - 1648
  • [6] Predictability of magnetic susceptibility artifacts from metallic orthodontic appliances in magnetic resonance imaging
    Blankenstein, Felix
    Buu Tai Truong
    Thomas, Andreas
    Thieme, Nadine
    Zachriat, Christine
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2015, 76 (01): : 14 - 29
  • [7] Preparation and characterization of Au-Pt alloy with ultra-low magnetic susceptibility
    Sun, Xiang
    Luo, Dong
    Luo, Jingran
    Lu, Jianmin
    Xia, Zhiwei
    Yan, Yi
    Fu, Quan
    Gan, Hongyu
    Zheng, Tianxu
    Song, Wei
    Liu, Yi
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1011
  • [8] Ultralow magnetic susceptibility in pure and Fe(Bi)-doped Au-Pt alloys improved by structural strain regulation
    Ma, Jun-Tao
    Xiao, Ye-Lei
    Zhang, Butian
    Wang, Shun
    Zhou, Ze-Bing
    Fu, Hua-Hua
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2025, 37 (04)
  • [10] Relation between magnetic susceptibility of non-ferromagnetic dental alloys and metal artifacts in magnetic resonance imaging (MRI).
    Shafiei, F.
    Honda, E.
    Takahashi, H.
    Sasaki, T.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B130 - B130