Use of the angle of progression on ultrasonography to predict spontaneous onset of labor within 7 days

被引:4
作者
Cho, Geum Joon [2 ]
Hong, Hye-Ri [3 ]
Seol, Hyun-Joo [3 ]
Koo, Bo Hae [2 ]
Hong, Soon-Cheol [2 ]
Oh, Min-Jeong [1 ]
Kim, Hai-Joong [2 ]
机构
[1] Korea Univ, Guro Hosp, Coll Med, Dept Obstet & Gynecol, Seoul 152703, South Korea
[2] Korea Univ, Coll Med, Dept Obstet & Gynecol, Seoul 152703, South Korea
[3] Kyung Hee Univ, Sch Med, Dept Obstet & Gynecol, Seoul, South Korea
关键词
Angle of progression; cervical length; labor; ultrasound; FETAL HEAD DESCENT; TRANSPERINEAL ULTRASOUND; CERVICAL LENGTH; UTERINE CERVIX; BISHOP SCORE; DELIVERY; PREGNANCY; STATION; TIME; TERM;
D O I
10.1515/jpm-2014-0106
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To investigate the relationship between angle of progression (AoP) on ultrasonography at 37-40 weeks' gestation and delivery within 7 days. Methods: This prospective study was conducted between January 2013 and May 2013 at Korea University Guro Hospital, Korea. Nulliparous women between 37/0 and 40/3 weeks' gestation with a singleton fetus, intact membrane, and cephalic presentation from January 2013 to May 2013 were enrolled. To evaluate the cervical parameters of cervical length and AoP, transvaginal and transperineal ultrasonography were performed, respectively. We then assessed the relationship between cervical parameters and onset of labor within 7 days by multivariate logistic regression analysis. Results: Women who underwent spontaneous onset of labor within 7 days had a significantly shorter cervical length and AoP than those who underwent labor after 7 days. Logistic regression analysis showed that a larger AoP was an independent predictor of spontaneous labor within 7 days. Conclusions: A larger AoP was significantly associated with spontaneous onset of labor within 7 days. These findings may be useful for counseling patients regarding the management of term pregnancies.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 17 条
[1]  
[Anonymous], ULTRASONOGRAPHY OBST
[2]   A new method to assess fetal head descent in labor with transperineal ultrasound [J].
Barbera, A. F. ;
Pombar, X. ;
Perugino, G. ;
Lezotte, D. C. ;
Hobbins, J. C. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 33 (03) :313-319
[3]   Cervical ultrasonography compared with manual examination as a predictor of preterm delivery [J].
Berghella, V ;
Tolosa, JE ;
Kuhlman, K ;
Weiner, S ;
Bolognese, RJ ;
Wapner, RJ .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 177 (04) :723-730
[4]  
BISHOP EH, 1964, OBSTET GYNECOL, V24, P266
[5]   Transvaginal sonographic assessment of cervical dynamics during the third trimester of normal pregnancy [J].
Brieger, GM ;
Ning, XH ;
Dawkins, RR ;
Ying, KQ ;
Weng, C ;
Chang, AMZ ;
Haines, CJ .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1997, 76 (02) :118-122
[6]   Measurement of fetal head descent using the 'angle of progression' on transperineal ultrasound imaging is reliable regardless of fetal head station or ultrasound expertise [J].
Dueckelmann, A. M. ;
Bamberg, C. ;
Michaelis, S. A. M. ;
Lange, J. ;
Nonnenmacher, A. ;
Dudenhausen, J. W. ;
Kalache, K. D. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 35 (02) :216-222
[7]   Prediction of labor and delivery by transperineal ultrasound in pregnancies with prelabor rupture of membranes at term [J].
Eggebo, TM ;
Gjessing, LK ;
Heien, C ;
Smedvig, E ;
Okland, I ;
Romundstad, P ;
Salvesen, KA .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 27 (04) :387-391
[8]   Intrapartum transperineal ultrasound assessment of fetal head progression in active second stage of labor and mode of delivery [J].
Ghi, T. ;
Youssef, A. ;
Maroni, E. ;
Arcangeli, T. ;
De Musso, F. ;
Bellussi, F. ;
Nanni, M. ;
Giorgetta, F. ;
Morselli-Labate, A. M. ;
Iammarino, M. T. ;
Paccapelo, A. ;
Cariello, L. ;
Rizzo, N. ;
Pilu, G. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 41 (04) :430-435
[9]   Three-dimensional ultrasound in monitoring progression of labor: a reproducibility study [J].
Ghi, T. ;
Contro, E. ;
Farina, A. ;
Nobile, M. ;
Pilu, G. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (04) :500-506
[10]   What is the most reliable ultrasound parameter for assessment of fetal head descent? [J].
Molina, F. S. ;
Terra, R. ;
Carrillo, M. P. ;
Puertas, A. ;
Nicolaides, K. H. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (04) :493-499