SELECTIVE RETINAL THERAPY WITH MICROSECOND EXPOSURES USING A CONTINUOUS LINE SCANNING LASER

被引:32
作者
Paulus, Yannis M. [1 ]
Jain, Atul [1 ]
Nomoto, Hiroyuki [1 ]
Sramek, Christopher [2 ]
Gariano, Ray F. [1 ]
Andersen, Dan [3 ]
Schuele, Georg [3 ]
Leung, Loh-Shan [1 ]
Leng, Theodore [1 ]
Palanker, Daniel [1 ,2 ]
机构
[1] Stanford Univ, Sch Med, Dept Ophthalmol, Stanford, CA 94305 USA
[2] Hansen Expt Phys Lab, Stanford, CA USA
[3] OptiMedica Inc, Santa Clara, CA USA
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2011年 / 31卷 / 02期
关键词
microsecond pulse duration; retinal laser photocoagulation; retinal pigment epithelium; scanning laser; selective retinal therapy; DIABETIC MACULAR EDEMA; PIGMENT EPITHELIUM; PULSE DURATION; PHOTOCOAGULATION; RETINOPATHY; NEOVASCULARIZATION; DAMAGE; EYES;
D O I
10.1097/IAE.0b013e3181e76da6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the safety, selectivity, and healing of retinal lesions created using a continuous line scanning laser. Methods: A 532-nm Nd:YAG laser (PASCAL) with retinal beam diameters of 40 mm and 66 mu m was applied to 60 eyes of 30 Dutch-belted rabbits. Retinal exposure duration varied from 15 mu s to 60 mu s. Lesions were acutely assessed by ophthalmoscopy and fluorescein angiography. Retinal pigment epithelial (RPE) flatmounts were evaluated with live-dead fluorescent assay. Histological analysis was performed at 7 time points from 1 hour to 2 months. Results: The ratios of the threshold of rupture and of ophthalmoscopic visibility to fluorescein angiography visibility (measures of safety and selectivity) increased with decreasing duration and beam diameter. Fluorescein angiography and live-dead fluorescent assay yielded similar thresholds of RPE damage. Above the ophthalmoscopic visibility threshold, histology showed focal RPE damage and photoreceptor loss at 1 day, without inner retinal effects. By 1 week, photoreceptor and RPE continuity was restored. By 1 month, photoreceptors appeared normal. Conclusion: Retinal therapy with a fast scanning continuous laser achieves selective targeting of the RPE and, at higher power, of the photoreceptors without permanent scarring or inner retinal damage. Continuous scanning laser can treat large retinal areas within standard eye fixation time. RETINA 31: 380-388, 2011
引用
收藏
页码:380 / 388
页数:9
相关论文
共 52 条
[1]   Pain response and follow-up of patients undergoing panretinal laser photocoagulation with reduced exposure times [J].
Al-Hussainy, S. ;
Dodson, P. M. ;
Gibson, J. M. .
EYE, 2008, 22 (01) :96-99
[2]  
[Anonymous], 1995, Arch Ophthalmol, V113, P1144
[3]   THEORETICAL INVESTIGATIONS OF LASER THERMAL RETINAL INJURY [J].
BIRNGRUBER, R ;
HILLENKAMP, F ;
GABEL, VP .
HEALTH PHYSICS, 1985, 48 (06) :781-796
[4]  
Birngruber R., 1991, LASER APPL MED BIOL, V5, P277
[5]   Semiautomated patterned scanning laser for retinal photocoagulation [J].
Blumenkranz, Mark S. ;
Yellachich, Dimitri ;
Andersen, Dan E. ;
Wiltberger, Michael W. ;
Mordaunt, David ;
Marcellino, George R. ;
Palanker, Daniel .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (03) :370-376
[6]  
Brinkmann R, 2006, Bull Soc Belge Ophtalmol, P51
[7]   Filling-in after focal loss of photoreceptors in rat retina [J].
Busch, EM ;
Gorgels, TGMF ;
van Norren, D .
EXPERIMENTAL EYE RESEARCH, 1999, 68 (04) :485-492
[8]   Selective retina therapy in patients with central serous chorioretinopathy [J].
Elsner, H. ;
Poerksen, E. ;
Klatt, C. ;
Bunse, A. ;
Theisen-Kunde, D. ;
Brinkmann, R. ;
Birngruber, R. ;
Laqua, H. ;
Roider, J. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (12) :1638-1645
[9]   Selective retina therapy in patients with diabetic maculopathy [J].
Elsner H. ;
Klatt C. ;
Liew S.H.M. ;
Pörksen E. ;
Bunse A. ;
Rudolf M. ;
Brinkmann R. ;
Hamilton R.P. ;
Birngruber R. ;
Laqua H. ;
Roider J. .
Der Ophthalmologe, 2006, 103 (10) :856-860
[10]  
FERRIS FL, 1987, OPHTHALMOLOGY, V94, P761