Multiple-Bolus Dynamic Contrast-Enhanced MRI in the Pancreas During a Glucose Challenge

被引:10
作者
Naish, J. H. [1 ,2 ]
Hutchinson, C. E. [1 ,2 ]
Caunce, A. [1 ,2 ]
Roberts, C. [1 ,2 ]
Waterton, J. C. [1 ,2 ,3 ]
Hockings, P. D. [4 ]
Taylor, C. J. [1 ,2 ]
Parker, G. J. M. [1 ,2 ]
机构
[1] Univ Manchester, Sch Canc & Enabling Sci, Manchester M13 9PT, Lancs, England
[2] Univ Manchester, Biomed Imaging Inst, Manchester, Lancs, England
[3] AstraZeneca, Translat Sci, Macclesfield, Cheshire, England
[4] AstraZeneca, Translat Sci, Molndal, Sweden
关键词
dynamic contrast-enhanced MRI; DCE-MRI; pancreas; diabetes; image registration; HEALTHY-VOLUNTEERS; PERFUSION;
D O I
10.1002/jmri.22281
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of multiple-bolus dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) in the pancreas; to optimize the analysis; and to investigate application of the method to a glucose challenge in type 2 diabetes. Materials and Methods: A 4-bolus DCE-MRI protocol was performed on five patients with type 2 diabetes and 11 healthy volunteers during free-breathing. Motion during the dynamic time series was corrected for using a model-driven nonlinear registration. A glucose challenge was administered intravenously between the first and second DCE-MRI acquisition in all patients and in seven of the healthy controls. Results: Image registration improved the reproducibility. of the DCE-MRI model parameters across the repeated bolus-acquisitions in the healthy controls with no glucose challenge (eg, coefficient of variation for K(trans) improved from 38% to 28%). Native tissue T(1) was significantly lower in patients (374 +/- 68 msec) compared with volunteers (519 +/- 41 msec) but there was no significant difference in any of the baseline DCE-MRI parameters. No effect of glucose challenge was observed in either the patients or healthy volunteers. Conclusion: Multiple bolus DCE-MRI is feasible in the pancreas and is improved by nonlinear image registration but is not sensitive to the effects of an intravenous glucose challenge.
引用
收藏
页码:622 / 628
页数:7
相关论文
共 14 条
[1]   Pancreatic perfusion:: Noninvasive quantitative assessment with dynamic contrast-enhanced MR imaging without and with secretin stimulation in healthy volunteers -: Initial results [J].
Bali, Maria Antonietta ;
Metens, Thierry ;
Denolin, Vincent ;
De Maertelaer, Viviane ;
Deviere, Jacques ;
Matos, Celso .
RADIOLOGY, 2008, 247 (01) :115-121
[2]   Tracer kinetic model-driven registration for dynamic contrast-enhanced MRI time-series data [J].
Buonaccorsi, Giovanni A. ;
O'Connor, James P. B. ;
Caunce, Angela ;
Roberts, Caleb ;
Cheung, Sue ;
Watson, Yvonne ;
Davies, Karen ;
Hope, Lynn ;
Jackson, Alan ;
Jayson, Gordon C. ;
Parker, Geoffrey J. M. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :1010-1019
[3]  
CAUNCE A, 2008, P 16 ANN M ISMRM TOR
[4]   Dynamic contrast-enhanced MRI of the pancreas: Initial results in healthy volunteers and patients with chronic pancreatitis [J].
Coenegrachts, K ;
Van Steenbergen, W ;
De Keyzer, F ;
Vanbeckevoort, D ;
Bielen, D ;
Chen, F ;
Dockx, S ;
Maes, F ;
Bosmans, H .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (06) :990-997
[5]   Pancreatic volume in type 1 and type 2 diabetes mellitus [J].
Goda, K ;
Sasaki, E ;
Nagata, K ;
Fukai, M ;
Ohsawa, N ;
Hahafusa, T .
ACTA DIABETOLOGICA, 2001, 38 (03) :145-149
[6]   SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING [J].
HAASE, A .
MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) :77-89
[7]   Comparative study of the physicochemical properties of six clinical low molecular weight gadolinium contrast agents [J].
Laurent, Sophie ;
Elst, Luce Vander ;
Muller, Robert N. .
CONTRAST MEDIA & MOLECULAR IMAGING, 2006, 1 (03) :128-137
[8]  
Li K L, 2000, J Magn Reson Imaging, V12, P347, DOI 10.1002/1522-2586(200008)12:2<347::AID-JMRI19>3.0.CO
[9]  
2-7
[10]  
Parker G, 2003, P 11 ANN M ISMRM TOR, P1264