Heart rate estimation from photoplethysmography signal for wearable health monitoring devices

被引:36
作者
Arunkumar, K. R. [1 ]
Bhaskar, M. [1 ]
机构
[1] Natl Inst Technol Tiruchirappalli, Dept Elect & Commun Engn, Tiruchirappalli 620015, Tamil Nadu, India
关键词
Wearable devices; Photoplethysmography; Heart rate estimation; Motion artifact; Combination of adaptive filters; Convex combination; PHYSICAL-EXERCISE; CONVEX COMBINATION; MOTION ARTIFACTS; PPG SIGNALS; REDUCTION; SCHEME; SENSOR;
D O I
10.1016/j.bspc.2019.01.021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable wrist type health monitoring devices use photoplethysmography (PPG) signal to estimate heart rate (HR). The HR estimation from these devices becomes difficult due to the existence of strong motion artifacts (MA) in PPG signal thereby leading to inaccurate HR estimation. The objective is to develop a novel de-noising algorithm that reduces the MA present in PPG signal, resulting in an accurate HR estimation. A novel de-noising technique using the hierarchical structure of cascade and parallel combinations of two different pairs of adaptive filters which reduces MA from the PPG signal and improves HR estimation is proposed. The first pair combines normalized least mean squares (NLMS) and recursive least squares (RLS) adaptive filters and the second pair combines recursive least squares (RLS) and least mean squares (LMS) adaptive filters. The de-noised signals obtained from the first and second pairs are combined to form a single de-noised PPG signal by means of convex combination. The HR of the de-noised PPG signal is estimated in the frequency domain using a Fast Fourier transform (FFT). Performance of the proposed technique is evaluated using a dataset of 12 individuals performing running activity in Treadmill. It resulted in an average absolute error of 0.92 beats per minute (BPM), standard deviation of the absolute error of 1.17 beats per minute (BPM), average relative error of 0.72 and Pearson correlation coefficient of 0.9973. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
[41]   Estimation of Heart Rate during Exercise from a Photoplethysmographic Signal Considering Exercise Intensity [J].
Hayashi, Takahiro ;
Ooi, Tatsuya .
SENSORS AND MATERIALS, 2016, 28 (04) :341-348
[42]   3D Printed Wearable FBG based Devices: A Proof of Concept for Heart Rate Monitoring [J].
Tavares, Catia ;
Leitao, Catia ;
Lo Presti, Daniela ;
Schena, Emiliano ;
Domingues, M. Fatima ;
Alberto, Nelia ;
Da Silva, Hugo Placido ;
Antunes, Paulo .
PROCEEDINGS OF 2022 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR INDUSTRY 4.0 & IOT (IEEE METROIND4.0&IOT), 2022, :366-370
[43]   Recent Advances in the Wearable Devices for Monitoring and Management of Heart Failure [J].
Odeh, Victor Adeyi ;
Chen, Yifan ;
Wang, Wenyan ;
Ding, Xiaorong .
REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (10)
[44]   Estimation of respiratory rate from motion contaminated photoplethysmography signals incorporating accelerometry [J].
Jarchi, Delaram ;
Charlton, Peter ;
Pimentel, Marco ;
Casson, Alex ;
Tarassenko, Lionel ;
Clifton, David A. .
HEALTHCARE TECHNOLOGY LETTERS, 2019, 6 (01) :19-26
[45]   A Sliding Scale Signal Quality Metric of Photoplethysmography Applicable to Measuring Heart Rate across Clinical Contexts with Chest Mounting as a Case Study [J].
McLean, Marnie K. K. ;
Weaver, R. Glenn ;
Lane, Abbi ;
Smith, Michal T. T. ;
Parker, Hannah ;
Stone, Ben ;
McAninch, Jonas ;
Matolak, David W. W. ;
Burkart, Sarah ;
Chandrashekhar, M. V. S. ;
Armstrong, Bridget .
SENSORS, 2023, 23 (07)
[46]   Deep Learning for Heart Rate Estimation From Reflectance Photoplethysmography With Acceleration Power Spectrum and Acceleration Intensity [J].
Chung, Heewon ;
Ko, Hoon ;
Lee, Hooseok ;
Lee, Jinseok .
IEEE ACCESS, 2020, 8 :63390-63402
[47]   A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts [J].
Ye, Yalan ;
He, Wenwen ;
Cheng, Yunfei ;
Huang, Wenxia ;
Zhang, Zhilin .
SENSORS, 2017, 17 (02)
[48]   Personal Wearable Devices to Measure Heart Rate Variability: A Framework of Cloud Platform for Public Health Research [J].
Tsoi, Kelvin K. F. ;
Wong, Janet Y. H. ;
Wong, Michael P. F. ;
Leung, Gary K. S. ;
Bat, Baker K. K. ;
Chan, Felix C. H. ;
Kuo, Yong-Hong ;
Lo, Herman H. M. ;
Meng, Helen M. L. .
PROCEEDINGS OF THE 2017 INTERNATIONAL CONFERENCE ON DIGITAL HEALTH (DH'17), 2017, :207-208
[49]   A Validation of Six Wearable Devices for Estimating Sleep, Heart Rate and Heart Rate Variability in Healthy Adults [J].
Miller, Dean J. ;
Sargent, Charli ;
Roach, Gregory D. .
SENSORS, 2022, 22 (16)
[50]   Contributions to the Acquisition of Heart Rate and Photoplethysmography Signal using a Real-Time Software [J].
Souza, Pedro H. de B. ;
Souza, Israel M. B. ;
Sacramento, Tharcis P. ;
Lima, Patricia C. M. ;
Vitorino, Priscila V. O. ;
Ramos, Gabrielly C. ;
Barbosa, Talles M. G. A. ;
da Rocha, Adson F. .
2018 IEEE INTERNATIONAL CONFERENCE ON HEALTHCARE INFORMATICS (ICHI), 2018, :332-337