Heart rate estimation from photoplethysmography signal for wearable health monitoring devices

被引:36
作者
Arunkumar, K. R. [1 ]
Bhaskar, M. [1 ]
机构
[1] Natl Inst Technol Tiruchirappalli, Dept Elect & Commun Engn, Tiruchirappalli 620015, Tamil Nadu, India
关键词
Wearable devices; Photoplethysmography; Heart rate estimation; Motion artifact; Combination of adaptive filters; Convex combination; PHYSICAL-EXERCISE; CONVEX COMBINATION; MOTION ARTIFACTS; PPG SIGNALS; REDUCTION; SCHEME; SENSOR;
D O I
10.1016/j.bspc.2019.01.021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable wrist type health monitoring devices use photoplethysmography (PPG) signal to estimate heart rate (HR). The HR estimation from these devices becomes difficult due to the existence of strong motion artifacts (MA) in PPG signal thereby leading to inaccurate HR estimation. The objective is to develop a novel de-noising algorithm that reduces the MA present in PPG signal, resulting in an accurate HR estimation. A novel de-noising technique using the hierarchical structure of cascade and parallel combinations of two different pairs of adaptive filters which reduces MA from the PPG signal and improves HR estimation is proposed. The first pair combines normalized least mean squares (NLMS) and recursive least squares (RLS) adaptive filters and the second pair combines recursive least squares (RLS) and least mean squares (LMS) adaptive filters. The de-noised signals obtained from the first and second pairs are combined to form a single de-noised PPG signal by means of convex combination. The HR of the de-noised PPG signal is estimated in the frequency domain using a Fast Fourier transform (FFT). Performance of the proposed technique is evaluated using a dataset of 12 individuals performing running activity in Treadmill. It resulted in an average absolute error of 0.92 beats per minute (BPM), standard deviation of the absolute error of 1.17 beats per minute (BPM), average relative error of 0.72 and Pearson correlation coefficient of 0.9973. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
[31]   Autoencoder-based Photoplethysmography (PPG) signal reliability enhancement in construction health monitoring [J].
Gautam, Yogesh ;
Jebelli, Houtan .
AUTOMATION IN CONSTRUCTION, 2024, 165
[32]   Statistical Investigation of Heart Rate Variable Derived from Photoplethysmography Signal in Sleep Staging Process [J].
Ucar, Muhammed Kursad ;
Bozkurt, Mehmet Recep ;
Bilgin, Cahit .
2017 25TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2017,
[33]   Sampling Rate Reduction for Wearable Heart Rate Variability Monitoring [J].
Nishikawa, Yuki ;
Izumi, Shintaro ;
Yano, Yuji ;
Kawaguchi, Hiroshi ;
Yoshimoto, Masahiko .
2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
[34]   PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring-A Comprehensive Review [J].
Lapsa, Didzis ;
Janeliukstis, Rims ;
Metshein, Margus ;
Selavo, Leo .
APPLIED SCIENCES-BASEL, 2024, 14 (17)
[35]   Finite State Machine Framework for Instantaneous Heart Rate Validation Using Wearable Photoplethysmography During Intensive Exercise [J].
Chung, Heewon ;
Lee, Hooseok ;
Lee, Jinseok .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2019, 23 (04) :1595-1606
[36]   Development of a blood pressure estimation hybrid deep learning system for wearable devices based on photoplethysmography [J].
Jeong S. ;
Kim Y. ;
Jo E.H. ;
Min S.D. .
Transactions of the Korean Institute of Electrical Engineers, 2021, 70 (08) :1208-1214
[37]   Photoplethysmography-Based Heart Rate Monitoring Using Asymmetric Least Squares Spectrum Subtraction and Bayesian Decision Theory [J].
Sun, Biao ;
Zhang, Zhilin .
IEEE SENSORS JOURNAL, 2015, 15 (12) :7161-7168
[38]   Review on Heart-Rate Estimation from Photoplethysmography and Accelerometer Signals During Physical Exercise [J].
Periyasamy, Vijitha ;
Pramanik, Manojit ;
Ghosh, Prasanta Kumar .
JOURNAL OF THE INDIAN INSTITUTE OF SCIENCE, 2017, 97 (03) :313-324
[39]   Wearable Devices for Precision Medicine and Health State Monitoring [J].
Jeong, In Cheol ;
Bychkov, David ;
Searson, Peter C. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (05) :1242-1258
[40]   Wearable Devices in Health Monitoring from the Environmental towards Multiple Domains: A Survey [J].
Haghi, Mostafa ;
Danyali, Saeed ;
Ayasseh, Sina ;
Wang, Ju ;
Aazami, Rahmat ;
Deserno, Thomas M. .
SENSORS, 2021, 21 (06) :1-24