Heart rate estimation from photoplethysmography signal for wearable health monitoring devices

被引:36
作者
Arunkumar, K. R. [1 ]
Bhaskar, M. [1 ]
机构
[1] Natl Inst Technol Tiruchirappalli, Dept Elect & Commun Engn, Tiruchirappalli 620015, Tamil Nadu, India
关键词
Wearable devices; Photoplethysmography; Heart rate estimation; Motion artifact; Combination of adaptive filters; Convex combination; PHYSICAL-EXERCISE; CONVEX COMBINATION; MOTION ARTIFACTS; PPG SIGNALS; REDUCTION; SCHEME; SENSOR;
D O I
10.1016/j.bspc.2019.01.021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable wrist type health monitoring devices use photoplethysmography (PPG) signal to estimate heart rate (HR). The HR estimation from these devices becomes difficult due to the existence of strong motion artifacts (MA) in PPG signal thereby leading to inaccurate HR estimation. The objective is to develop a novel de-noising algorithm that reduces the MA present in PPG signal, resulting in an accurate HR estimation. A novel de-noising technique using the hierarchical structure of cascade and parallel combinations of two different pairs of adaptive filters which reduces MA from the PPG signal and improves HR estimation is proposed. The first pair combines normalized least mean squares (NLMS) and recursive least squares (RLS) adaptive filters and the second pair combines recursive least squares (RLS) and least mean squares (LMS) adaptive filters. The de-noised signals obtained from the first and second pairs are combined to form a single de-noised PPG signal by means of convex combination. The HR of the de-noised PPG signal is estimated in the frequency domain using a Fast Fourier transform (FFT). Performance of the proposed technique is evaluated using a dataset of 12 individuals performing running activity in Treadmill. It resulted in an average absolute error of 0.92 beats per minute (BPM), standard deviation of the absolute error of 1.17 beats per minute (BPM), average relative error of 0.72 and Pearson correlation coefficient of 0.9973. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
[21]   Novel wearable and contactless heart rate, respiratory rate, and oxygen saturation monitoring devices: a systematic review and meta-analysis [J].
Chan, P. Y. ;
Ryan, N. P. ;
Chen, D. ;
McNeil, J. ;
Hopper, I .
ANAESTHESIA, 2022, 77 (11) :1268-1280
[22]   Combining Photoplethysmography and Ballistocardiography to Address Voluntary Head Movements in Heart Rate Monitoring [J].
Lomaliza, Jean-Pierre ;
Park, Hanhoon ;
Billinghurst, Mark .
IEEE ACCESS, 2020, 8 :226224-226239
[23]   Q-PPG: Energy-Efficient PPG-Based Heart Rate Monitoring on Wearable Devices [J].
Burrello, Alessio ;
Pagliari, Daniele Jahier ;
Risso, Matteo ;
Benatti, Simone ;
Macii, Enrico ;
Benini, Luca ;
Poncino, Massimo .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (06) :1196-1209
[24]   Cardiovascular health monitoring using multiple conformal photoplethysmography devices [J].
Lee, Y. .
SOFT MECHATRONICS AND WEARABLE SYSTEMS, 2024, 12948
[25]   A survey on security and privacy issues in wearable health monitoring devices [J].
Zhang, Bonan ;
Chen, Chao ;
Lee, Ickjai ;
Lee, Kyungmi ;
Ong, Kok-Leong .
COMPUTERS & SECURITY, 2025, 155
[26]   Wrist Photoplethysmography Signal Quality Assessment for Reliable Heart Rate Estimate and Morphological Analysis [J].
Moscato, Serena ;
Lo Giudice, Stella ;
Massaro, Giulia ;
Chiari, Lorenzo .
SENSORS, 2022, 22 (15)
[27]   Green Light Photoplethysmography as a Substitute for Heart Rate Variability Monitoring [J].
Maeda, Yuka ;
Sekine, Masaki ;
Tamura, Toshiyo ;
Mizutani, Koichi .
ADVANCED BIOMEDICAL ENGINEERING, 2024, 13 :301-306
[28]   Wearable triboelectric nanogenerators for heart rate monitoring [J].
Shen, Sophia ;
Xiao, Xiao ;
Xiao, Xiao ;
Chen, Jun .
CHEMICAL COMMUNICATIONS, 2021, 57 (48) :5871-5879
[29]   Heart rate estimation based on a new scheme during intensive exercise from Photoplethysmography [J].
Song, Xuhui ;
Yuan, Xueguang ;
Zhang, Yang'An ;
Gong, Chen ;
Xu, Shengyao ;
Huang, Yongqing .
2018 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE (ACP), 2018,
[30]   Indirect Estimation of Breathing Rate through Wearable Devices [J].
Cosoli, Gloria ;
Antognoli, Luca ;
Scalise, Lorenzo .
2022 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA 2022), 2022,