Heart rate estimation from photoplethysmography signal for wearable health monitoring devices

被引:36
作者
Arunkumar, K. R. [1 ]
Bhaskar, M. [1 ]
机构
[1] Natl Inst Technol Tiruchirappalli, Dept Elect & Commun Engn, Tiruchirappalli 620015, Tamil Nadu, India
关键词
Wearable devices; Photoplethysmography; Heart rate estimation; Motion artifact; Combination of adaptive filters; Convex combination; PHYSICAL-EXERCISE; CONVEX COMBINATION; MOTION ARTIFACTS; PPG SIGNALS; REDUCTION; SCHEME; SENSOR;
D O I
10.1016/j.bspc.2019.01.021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable wrist type health monitoring devices use photoplethysmography (PPG) signal to estimate heart rate (HR). The HR estimation from these devices becomes difficult due to the existence of strong motion artifacts (MA) in PPG signal thereby leading to inaccurate HR estimation. The objective is to develop a novel de-noising algorithm that reduces the MA present in PPG signal, resulting in an accurate HR estimation. A novel de-noising technique using the hierarchical structure of cascade and parallel combinations of two different pairs of adaptive filters which reduces MA from the PPG signal and improves HR estimation is proposed. The first pair combines normalized least mean squares (NLMS) and recursive least squares (RLS) adaptive filters and the second pair combines recursive least squares (RLS) and least mean squares (LMS) adaptive filters. The de-noised signals obtained from the first and second pairs are combined to form a single de-noised PPG signal by means of convex combination. The HR of the de-noised PPG signal is estimated in the frequency domain using a Fast Fourier transform (FFT). Performance of the proposed technique is evaluated using a dataset of 12 individuals performing running activity in Treadmill. It resulted in an average absolute error of 0.92 beats per minute (BPM), standard deviation of the absolute error of 1.17 beats per minute (BPM), average relative error of 0.72 and Pearson correlation coefficient of 0.9973. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 36 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   Mean-square performance of a convex combination of two adaptive filters [J].
Arenas-García, J ;
Figueiras-Vidal, AR ;
Sayed, AH .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2006, 54 (03) :1078-1090
[3]   Combinations of Adaptive Filters [J].
Arenas-Garcia, Jeronimo ;
Azpicueta-Ruiz, Luis A. ;
Silva, Magno T. M. ;
Nascimento, Vitor H. ;
Sayed, Ali H. .
IEEE SIGNAL PROCESSING MAGAZINE, 2016, 33 (01) :120-140
[4]   Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables [J].
Baek, Hyun Jae ;
Shin, JaeWook .
JOURNAL OF MEDICAL SYSTEMS, 2017, 41 (10)
[5]  
Biswas A., 2019, RECENT TRENDS SIGNAL
[6]  
Chen Y., 2017, EHEALTH 360, V360
[7]   Real-Time Robust Heart Rate Estimation From Wrist-Type PPG Signals Using Multiple Reference Adaptive Noise Cancellation [J].
Chowdhury, Sayeed Shafayet ;
Hyder, Rakib ;
Bin Hafiz, Md. Samzid ;
Haque, Mohammad Ariful .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (02) :450-459
[8]   Alteration of Arterial Mechanical Impedance Greater than that of Photoplethysmogram and Laser Doppler Flowmetry during Endoscopic Thoracic Sympathectomy [J].
Elbegzaya, Sukhdorj ;
Nakamura, Ryuji ;
Saeki, Noboru ;
Yanabe, Kensuke ;
Kutluk, Abdugheni ;
Hirano, Hiroki ;
Hirano, Harutoyo ;
Tsuji, Toshio ;
Kawamoto, Masashi .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2017, 37 (06) :820-825
[9]   Measuring Heart Rate During Physical Exercise by Subspace Decomposition and Kalman Smoothing [J].
Galli, Alessandra ;
Narduzzi, Claudio ;
Giorgi, Giada .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2018, 67 (05) :1102-1110
[10]   Assessment of Subtle Changes in Diabetes-Associated Arteriosclerosis using Photoplethysmographic Pulse Wave from Index Finger [J].
Hsu, Po-Chun ;
Wu, Hsien-Tsai ;
Sun, Cheuk-Kwan .
JOURNAL OF MEDICAL SYSTEMS, 2018, 42 (03)