Establishing repeatability and ruggedness of chiral separations in micellar electrokinetic chromatography mass spectrometry: Combined use of covalently bonded capillary column and molecular micelles

被引:12
作者
Akter, Ferdoushi [1 ]
Shamsi, Shahab A. [1 ]
机构
[1] Georgia State Univ, Dept Chem, Atlanta, GA 30302 USA
关键词
Micellar electrokinetic; chromatography-mass spectrometry (MEKC-MS); beta-blockers; Poly-L-SUCL; Chiral analysis; AMPS bonded capillary column; ATMOSPHERIC-PRESSURE PHOTOIONIZATION; AMINO-ACID SURFACTANTS; SIMULTANEOUS ENANTIOSEPARATION; ELECTROPHORESIS; MEKC;
D O I
10.1016/j.chroma.2019.460835
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although micellar electrokinetic chromatography-mass spectrometry (MEKC-MS) using bare silica capillary filled with molecular micelles is an advantageous hyphenated technique for chiral analysis, it is still in the developmental stage. This is mainly because of the lower repeatability of retention time and peak area associated with the difficulty in controlling electroosmotic flow on bare silica capillaries. Besides the lower robustness and electrospray erosion of the fused-silica capillary tip, the lifetime is limited for 10-15 runs per capillary column. We have tested a new MEKC-MS method to eradicate this problem using a covalently bonded 2-acrylamido-2-methyl-1-propane-sulfonic acid (AMPS) column filled with free floating molecular micelles, polysodium N-undecenoxy carbonyl-L-leucinate (poly-L-SUCL). Simultaneous enantiomeric separations and MS/MS detection of three beta-blockers [atenolol (ATEN), metoprolol (METO) and, pindolol (PINDO)] was achieved within 25 min with improved column lifetime of at least 45-50 runs. Excellent repeatability of retention time was observed for beta-blockers, as evidenced by the relative standard deviation of less than 2% and 3% for intra-capillary and inter-capillary column, respectively. The linear calibration range of both beta-blockers was simultaneously established using enantiomers of PINDO as an internal standard. The limit of detection and the lower limit of quantitation were 0.2 mu g/mL and 0.5 mu g/mL, respectively, for both ATEN and METO. Acceptable recovery of the enantiomeric content of the commercial METO tablet (98-99.5%) and ATEN tablet (89-92.5%) were obtained with adequate system suitability for the precision of peak area (<= 10% RSD) under optimum conditions. The developed MEKC-MS approach was extended, which provided broader repeatibility of chiral separation to a panel of primary, secondary and tertiary amines as well as one anionic chiral compound. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 20 条
[1]   Simultaneous enantioseparation and tandem UV-MS detection of eight β-blockers in micellar electrokinetic chromatography using a chiral molecular micelle [J].
Akbay, C ;
Rizvi, SAA ;
Shamsi, SA .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1672-1683
[2]  
Beesley T. E., 1998, SEPAR SCI S
[3]   Use of negatively charged cyclodextrins for the simultaneous enantioseparation of selected anesthetic drugs by capillary electrophoresis-mass spectrometry [J].
Cherkaoui, S ;
Veuthey, JL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (3-4) :615-626
[4]  
He Jun, 2013, Methods Mol Biol, V970, P319, DOI 10.1007/978-1-62703-263-6_21
[5]   Chiral micellar electrokinetic chromatography-atmospheric pressure photoionization of benzoin derivatives using mixed molecular micelles [J].
He, Jun ;
Shamsi, Shahab A. .
ELECTROPHORESIS, 2011, 32 (10) :1164-1175
[6]   Capillary Electrophoresis-Atmospheric Pressure Chemical Ionization-Mass Spectrometry Using an Orthogonal Interface: Set-Up and System Parameters [J].
Hommerson, Paul ;
Khan, Amjad M. ;
de Jong, Gerhardus J. ;
Somsen, Govert W. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (07) :1311-1318
[7]   Application of polymeric surfactants in micellar electrokinetic chromatography-electrospray ionization mass spectrometry of benzodiazepines and benzoxazocine chiral drugs [J].
Hou, JG ;
Rizvi, SAA ;
Zheng, J ;
Shamsi, SA .
ELECTROPHORESIS, 2006, 27 (5-6) :1263-1275
[8]   Simultaneous chiral separation and determination of ephedrine alkaloids by MEKC-ESI-MS using polymeric surfactant I: Method development [J].
Hou, Jingguo ;
Zheng, Jie ;
Rizvi, Syed A. A. ;
Shamsi, Shahab A. .
ELECTROPHORESIS, 2007, 28 (09) :1352-1363
[9]   Chiral separation of intact amino acids by capillary electrophoresis-mass spectrometry employing a partial filling technique with a crown ether carboxylic acid [J].
Lee, Sul ;
Kim, Su-Jin ;
Bang, Eunjung ;
Na, Yun-Cheol .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1586 :128-138
[10]   Synthesis, characterization, and application of polysodium N-alkylenyl α-D-glucopyranoside surfactants for micellar electrokinetic chromatography-tandem mass spectrometry [J].
Liu, Yijin ;
Wu, Baolin ;
Wang, Peng ;
Shamsi, Shahab A. .
ELECTROPHORESIS, 2016, 37 (7-8) :913-923