Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments

被引:98
作者
Huang, Yan [1 ,2 ,3 ]
Xu, Tailin [1 ]
Wang, Wenqian [1 ]
Wen, Yongqiang [1 ]
Li, Kun [2 ]
Qian, Lisheng [2 ]
Zhang, Xueji [1 ,2 ,4 ]
Liu, Guodong [2 ,3 ]
机构
[1] Univ Sci & Technol Beijing, Res Ctr Bioengn & Sensing Technol, Beijing 100083, Peoples R China
[2] Anhui Sci & Technol Univ, Sch Life & Hlth Sci, Inst Biomed & Hlth, Fengyang 233100, Anhui, Peoples R China
[3] North Dakota State Univ, Dept Chem & Biochem, Fargo, ND 58105 USA
[4] Shenzhen Univ, Sch Biomed Engn, Hlth Sci Ctr, Shenzhen 518060, Guangdong, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金; 北京市自然科学基金;
关键词
Lateral flow assay; Strip biosensor; Vertical flow assay; Sample pretreatment; Flow control; Reliability improvement; Smartphone; Nanoparticles; SERS; Optical sensors; PORTABLE FLUORESCENCE BIOSENSOR; NUCLEIC-ACID BIOSENSOR; RECOMBINASE POLYMERASE AMPLIFICATION; FUNCTIONALIZED GOLD NANOPARTICLES; BACILLUS-ANTHRACIS SPORES; REAGENT STRIP BIOSENSOR; C-REACTIVE PROTEIN; IMMUNOCHROMATOGRAPHIC ASSAY; VISUAL DETECTION; RAPID DETECTION;
D O I
10.1007/s00604-019-3822-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This review (with 187 refs.) summarizes the progress that has been made in the design of lateral flow biosensors (LFBs) based on the use of micro- and nano-materials. Following a short introduction into the field, a first section covers features related to the design of LFBs, with subsections on strip-based, cotton thread-based and vertical flow- and syringe-based LFBs. The next chapter summarizes methods for sample pretreatment, from simple method to membrane-based methods, pretreatment by magnetic methods to device-integrated sample preparation. Advances in flow control are treated next, with subsections on cross-flow strategies, delayed and controlled release and various other strategies. Detection conditionst and mathematical modelling are briefly introduced in the following chapter. A further chapter covers methods for reliability improvement, for example by adding other validation lines or adopting different detection methods. Signal readouts are summarized next, with subsections on color-based, luminescent, smartphone-based and SERS-based methods. A concluding section summarizes the current status and addresses challenges in future perspectives.
引用
收藏
页数:25
相关论文
共 186 条
[1]   Multifunctional Analytical Platform on a Paper Strip: Separation, Preconcentration, and Subattomolar Detection [J].
Abbas, Abdennour ;
Brimer, Andrew ;
Slocik, Joseph M. ;
Tian, Limei ;
Naik, Rajesh R. ;
Singamaneni, Srikanth .
ANALYTICAL CHEMISTRY, 2013, 85 (08) :3977-3983
[2]   An interference-free and rapid electrochemical lateral-flow immunoassay for one-step ultrasensitive detection with serum [J].
Akanda, Md. Rajibul ;
Joung, Hyou-Arm ;
Tamilavan, Vellaiappillai ;
Park, Seonhwa ;
Kim, Sinyoung ;
Hyun, Myung Ho ;
Kim, Min-Gon ;
Yang, Haesik .
ANALYST, 2014, 139 (06) :1420-1425
[3]   A lateral flow immunoassay for straightforward determination of fumonisin mycotoxins based on the quenching of the fluorescence of CdSe/ZnS quantum dots by gold and silver nanoparticles [J].
Anfossi, Laura ;
Di Nardo, Fabio ;
Cavalera, Simone ;
Giovannoli, Cristina ;
Spano, Giulia ;
Speranskaya, Elena S. ;
Goryacheva, Irina Y. ;
Baggiani, Claudio .
MICROCHIMICA ACTA, 2018, 185 (02)
[4]   Ambient temperature detection of PCR amplicons with a novel sequence-specific nucleic acid lateral flow biosensor [J].
Ang, Geik Yong ;
Yu, Choo Yee ;
Yean, Chan Yean .
BIOSENSORS & BIOELECTRONICS, 2012, 38 (01) :151-156
[5]   Rapid and sensitive lateral flow immunoassay for influenza antigen using fluorescently-doped silica nanoparticles [J].
Bamrungsap, Suwussa ;
Apiwat, Chayachon ;
Chantima, Warangkana ;
Dharakul, Tararaj ;
Wiriyachaiporn, Natpapas .
MICROCHIMICA ACTA, 2014, 181 (1-2) :223-230
[6]   Vertical-flow paper SERS system for therapeutic drug monitoring of flucytosine in serum [J].
Berger, Adam G. ;
Restaino, Stephen M. ;
White, Ian M. .
ANALYTICA CHIMICA ACTA, 2017, 949 :59-66
[7]   Vertical flow-based paper immunosensor for rapid electrochemical and colorimetric detection of influenza virus using a different pore size sample pad [J].
Bhardwaj, Jyoti ;
Sharma, Abhinav ;
Jang, Jaesung .
BIOSENSORS & BIOELECTRONICS, 2019, 126 :36-43
[8]   Strip-based immunoassay for rapid detection of thiabendazole [J].
Blazkova, Martina ;
Rauch, Pavel ;
Fukal, Ladislav .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) :2122-2128
[9]   Immunochromatographic strip for rapid detection of Cronobacter in powdered infant formula in combination with silica-coated magnetic nanoparticles separation and 16S rRNA probe [J].
Chen, Fei ;
Ming, Xing ;
Chen, XingXing ;
Gan, Min ;
Wang, BaoGui ;
Xu, Feng ;
Wei, Hua .
BIOSENSORS & BIOELECTRONICS, 2014, 61 :306-313
[10]   Enzyme-free strip biosensor for amplified detection of Pb2+ based on a catalytic DNA circuit [J].
Chen, Junhua ;
Zhou, Xuemeng ;
Zeng, Lingwen .
CHEMICAL COMMUNICATIONS, 2013, 49 (10) :984-986