Effect of tissue density on PET spatial resolution in magnetic environment

被引:1
|
作者
Li, Chong [1 ,2 ]
Cao, Xingzhong [1 ,2 ]
Liu, Fuyan [1 ,2 ]
Zhang, Peng [1 ]
Zhang, Zhiming [1 ,2 ]
Wei, Long [1 ,2 ]
Wang, Baoyi [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100039, Peoples R China
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2020年 / 135卷 / 01期
关键词
MONTE-CARLO-SIMULATION; WHOLE-BODY PET/MR; POSITRONS;
D O I
10.1140/epjp/s13360-020-00198-x
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) can provide a strong magnetic field to improve the PET spatial resolution by restricting the positron range. In this study, an experimental system and a Geant4 model were built to investigate the difference in improved spatial resolution by using a magnetic field for PET in different human tissues. Experiment results indicated that the magnetic field enabled a greater compressive effect on the positron distribution in a low-density medium. From the simulation results, the magnetic compression was only effective in the direction perpendicular to the magnetic field. Additionally, the saturated relative change rates of the mean positron range were reached for all tissues with increasing magnetic field, and the saturated values exhibited an overall negative correlation with the tissue density. However, despite the considerable difference in the absolute range in different tissues, the saturated values were only in a very narrow range of approximately 45% to 50%, compared to the final relative change rates. It was revealed that the magnetic field can be a more effective method for improving the PET imaging quality for low-density tissues, and there should be an upper threshold for improving the PET spatial resolution using a magnetic field. A range-corrected algorithm associated with tissue density for PET-MRI systems can probably be developed based on the results.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effect of tissue density on PET spatial resolution in magnetic environment
    Chong Li
    Xingzhong Cao
    Fuyan Liu
    Peng Zhang
    Zhiming Zhang
    Long Wei
    Baoyi Wang
    The European Physical Journal Plus, 135
  • [2] Evaluation of the effect of magnetic field on the positron range/PET spatial resolution in clinical PET scanners
    Cheng, Ju-Chieh
    Laforest, Richard
    Priatna, Agus
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [3] Evaluation of the effect of magnetic field on the PET spatial resolution and contrast recovery using clinical PET scanners and EGS simulations
    Cheng, Ju-Chieh
    Laforest, Richard
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2738 - 2741
  • [4] Evaluation of the Effect of Magnetic Field on PET Spatial Resolution and Contrast Recovery Using Clinical PET Scanners and EGSnrc Simulations
    Cheng, Ju-Chieh
    Boellaard, Ronald
    Laforest, Richard
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (01) : 101 - 110
  • [5] Investigation of the "block effect" on spatial resolution in PET detectors
    Tomic, N
    Thompson, CJ
    Casey, ME
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2201 - 2205
  • [6] Investigation of the "block effect" on spatial resolution in PET detectors
    Tomic, N
    Thompson, CJ
    Casey, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 599 - 605
  • [7] A PET Detector Ring with Homogenous Spatial Resolution in the Presence of a Magnetic Field
    Gonzalez, Antonio J.
    Aguilar, Albert
    Gonzalez-Montoro, Andrea
    Correcher, Carlos
    Conde, Pablo
    Molinos, Cesar
    Lankes, Konrad
    Junge, Sven
    Benlloch, Jose M.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [8] Magnetic Field and PET: Does the Effect of Magnetic Field vary with the Intrinsic Resolution of PET Scanners?
    Cheng, Ju-Chieh
    Laforest, Richard
    Boellaard, Ronald
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [9] Evaluation of PET Spatial Resolution on integrated PET/MR
    Xie, Feng
    Zhuang, Jingwen
    Wu, Tianqi
    Bai, Mei
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [10] Effect of recoil electron range on efficiency and on spatial resolution of very high resolution animal PET
    Park, S
    Rogers, WL
    Clinthorne, NH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1756 - 1759