Noninvasive detection of coronary allograft vasculopathy by myocardial contrast echocardiography

被引:15
作者
Rodrigues, ACT [1 ]
Bacal, F [1 ]
Medeiros, CC [1 ]
Bocchi, E [1 ]
Sbano, J [1 ]
Morhy, SS [1 ]
Mathias, W [1 ]
Andrade, JL [1 ]
机构
[1] Univ Sao Paulo, Hosp Clin, Fac Med, Inst Heart,InCor, Sao Paulo, Brazil
关键词
D O I
10.1016/j.echo.2004.09.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Noninvasive detection of coronary allograft vasculopathy is still challenging. To determine the accuracy of myocardial contrast echocardiography (MCE) in detecting coronary allograft vasculopathy after heart transplantation, we studied 35 asymptomatic patients (30 men, aged 46 +/- 12.7 years) with normal left ventricular function. Methods: Patients underwent MCE with continuous contrast (perfluorocarbon-exposed sonicated dextrose albumin) administration. Images were obtained at baseline and during peak dobutamine (up to 40 mg/kg/min) with intermittent harmonic imaging. Areas failing to increase contrast enhancement during peak stress were regarded as abnormal. Coronary artery obstructions greater than 50% at angiography were considered significant. Results. Seven out of 10 patients with coronary artery disease had a positive MCE and one patient with a positive MCE had no angiographically detected disease (sensitivity = 70%, specificity = 96%, accuracy = 88.6%). Agreement between the vascular territory and perfusion defects was good for the left anterior descending coronary artery (kappa = 0.56), but not for other arteries. Although 5 patients had multivessel disease, multiple perfusion defects were detected in only one patient. Conclusion: MCE showed good accuracy in detecting the presence of coronary allograft vasculopathy after heart transplantation; however, it failed to identify the extent of the disease.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 24 条
[21]   THE INFLUENCE OF ANGIOGRAPHICALLY DEMONSTRATED CORONARY COLLATERALS ON THE RESULTS OF STRESS ECHOCARDIOGRAPHY [J].
STONE, DA ;
CORRETTI, MC ;
HAWKE, MW ;
HERZOG, W ;
RODRIGUEZ, S ;
PLOTNICK, GD .
CLINICAL CARDIOLOGY, 1995, 18 (04) :205-208
[22]   Accuracy of dipyridamole SPECT imaging in identifying individual coronary stenoses and multivessel disease in women versus men [J].
Travin, MI ;
Katz, MS ;
Moulton, AW ;
Miele, NJ ;
Sharaf, BL ;
Johnson, LL .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (03) :213-220
[23]  
URETSKY BF, 1992, J HEART LUNG TRANSPL, V11, pS45
[24]   DOES VISUAL INTERPRETATION OF THE CORONARY ARTERIOGRAM PREDICT THE PHYSIOLOGIC IMPORTANCE OF A CORONARY STENOSIS [J].
WHITE, CW ;
WRIGHT, CB ;
DOTY, DB ;
HIRATZA, LF ;
EASTHAM, CL ;
HARRISON, DG ;
MARCUS, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 310 (13) :819-824