Noninvasive detection of coronary allograft vasculopathy by myocardial contrast echocardiography

被引:15
作者
Rodrigues, ACT [1 ]
Bacal, F [1 ]
Medeiros, CC [1 ]
Bocchi, E [1 ]
Sbano, J [1 ]
Morhy, SS [1 ]
Mathias, W [1 ]
Andrade, JL [1 ]
机构
[1] Univ Sao Paulo, Hosp Clin, Fac Med, Inst Heart,InCor, Sao Paulo, Brazil
关键词
D O I
10.1016/j.echo.2004.09.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Noninvasive detection of coronary allograft vasculopathy is still challenging. To determine the accuracy of myocardial contrast echocardiography (MCE) in detecting coronary allograft vasculopathy after heart transplantation, we studied 35 asymptomatic patients (30 men, aged 46 +/- 12.7 years) with normal left ventricular function. Methods: Patients underwent MCE with continuous contrast (perfluorocarbon-exposed sonicated dextrose albumin) administration. Images were obtained at baseline and during peak dobutamine (up to 40 mg/kg/min) with intermittent harmonic imaging. Areas failing to increase contrast enhancement during peak stress were regarded as abnormal. Coronary artery obstructions greater than 50% at angiography were considered significant. Results. Seven out of 10 patients with coronary artery disease had a positive MCE and one patient with a positive MCE had no angiographically detected disease (sensitivity = 70%, specificity = 96%, accuracy = 88.6%). Agreement between the vascular territory and perfusion defects was good for the left anterior descending coronary artery (kappa = 0.56), but not for other arteries. Although 5 patients had multivessel disease, multiple perfusion defects were detected in only one patient. Conclusion: MCE showed good accuracy in detecting the presence of coronary allograft vasculopathy after heart transplantation; however, it failed to identify the extent of the disease.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 24 条
[1]  
AKOSAH KO, 1994, J HEART LUNG TRANSPL, V13, P1024
[2]   Dobutamine stress echocardiography early after heart transplantation predicts development of allograft coronary artery disease and outcome [J].
Akosah, KO ;
McDaniel, S ;
Hanrahan, JS ;
Mohanty, PK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (07) :1607-1614
[3]   Safety profile and hemodynamic responses to β-adrenergic stimulation by dobutamine in heart transplant patients [J].
Akosah, KO ;
Denlinger, B ;
Mohanty, PK .
CHEST, 1999, 116 (06) :1587-1592
[4]  
Bacal F, 2001, Arq Bras Cardiol, V76, P29
[5]   Accuracy of exercise stress technetium 99m sestamibi SPECT imaging in the evaluation of the extent and location of coronary artery disease in patients with an earlier myocardial infarction [J].
Elhendy, A ;
Sozzi, FB ;
van Domburg, RT ;
Bax, JJ ;
Geleijnse, ML ;
Valkema, R ;
Krenning, EP ;
Roelandt, JRTC .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (05) :432-438
[6]   Accuracy of dobutamine tetrofosmin myocardial perfusion imaging for the noninvasive diagnosis of transplant coronary artery stenosis [J].
Elhendy, A ;
Sozzi, FB ;
van Domburg, RT ;
Vantrimpont, P ;
Valkema, R ;
Krenning, EP ;
Roelandt, JRTC ;
Maat, LPWM ;
Balk, AHMM .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2000, 19 (04) :360-366
[7]   ACCELERATED CORONARY VASCULAR-DISEASE IN THE HEART-TRANSPLANT PATIENT - CORONARY ARTERIOGRAPHIC FINDINGS [J].
GAO, SZ ;
ALDERMAN, EL ;
SCHROEDER, JS ;
SILVERMAN, JF ;
HUNT, SA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) :334-340
[8]   Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress comparison with 99mTc-Sestamibi SPECT imaging [J].
Heinle, SK ;
Noblin, J ;
Goree-Best, P ;
Mello, A ;
Ravad, G ;
Mull, S ;
Mammen, P ;
Grayburn, PA .
CIRCULATION, 2000, 102 (01) :55-60
[9]  
HERREGODS MC, 1994, J HEART LUNG TRANSPL, V13, P1039
[10]   The Registry of the International Society for Heart and Lung Transplantation: Eighteenth official report-2001 [J].
Hosenpud, JD ;
Bennett, LE ;
Keck, BM ;
Boucek, MM ;
Novick, RJ .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2001, 20 (08) :805-815