A New Method to Retrieve the Three-Dimensional Refractive Index and Specimen Size Using the Transport Intensity Equation, Taking Diffraction into Account

被引:3
作者
Agnero, Marcel A. [1 ,2 ]
Konan, Kouakou [1 ]
Kossonou, Alvarez T. [1 ]
Bagui, Olivier K. [1 ]
Zoueu, Jeremie T. [1 ]
机构
[1] Inst Natl Polytech Felix Houphouet Boigny INPH B, Lab Instrumentat Image & Spect, BP 1093, Yamoussoukro, Cote Ivoire
[2] Univ Felix Houphouet Boigny, UFR SSMT, Lab Phys Matiere Condensee & Technol, 22 BP 582, Abidjan 22, Cote Ivoire
来源
APPLIED SCIENCES-BASEL | 2018年 / 8卷 / 09期
关键词
tomography; refractive index; size determination; point spread function; transport intensity equation; diffraction; FLUORESCENCE MICROSCOPY; LIGHT-MICROSCOPY; PHASE RETRIEVAL; DECONVOLUTION; PARAMETERS; MODEL;
D O I
10.3390/app8091649
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Refractive index retrieval is possible using the transport intensity equation (TIE), which presents advantages over interferometric techniques. The TIE method is valid only for paraxial ray assumptions. However, diffraction can nullify these TIE model assumptions. Therefore, the refractive index is problematic for reconstruction in three-dimensions (3D) using a set of defocused images, as diffraction effects become prominent. We propose a method to recover the 3D refractive index by combining TIE and deconvolution. A brightfield (BF) microscope was then constructed to apply the proposed technique. A microsphere was used as a sample with well-known properties. The deconvolution of the BF-images of the sample using the microscope's 3D point spread function led to significantly reduced diffraction effects. TIE was then applied for each set of three images. Applying TIE without taking into account diffraction failed to reconstruct the 3D refractive index. Taking diffraction into account, the refractive index of the sample was clearly recovered, and the sectioning effect of the microsphere was highlighted, leading to a determination of its size. This work is of great significance in improving the 3D reconstruction of the refractive index using the TIE method.
引用
收藏
页数:11
相关论文
共 37 条
  • [1] Agnero M.A., 2016, OPT PHOTONICS J, V6, P171, DOI [10.4236/opj.2016.67019, DOI 10.4236/OPJ.2016.67019]
  • [2] An accurate PSF model with few parameters for axially shift-variant deconvolution
    Aguet, Francois
    Van De Ville, Dimitri
    Unser, Michael
    [J]. 2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 157 - 160
  • [3] Phase retrieval from series of images obtained by defocus variation
    Allen, LJ
    Oxley, MP
    [J]. OPTICS COMMUNICATIONS, 2001, 199 (1-4) : 65 - 75
  • [4] BARER R, 1954, Q J MICROSC SCI, V95, P399
  • [5] Besson P., 2005, PSF GIBSON GENERATOR
  • [6] Versatile multispectral microscope based on light emitting diodes
    Brydegaard, Mikkel
    Merdasa, Aboma
    Jayaweera, Hiran
    Alebring, Jens
    Svanberg, Sune
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (12)
  • [7] Chao Z., 2014, P SOC PHOTO-OPT INS, V9271
  • [8] Chao Z., 2013, FRINGE, DOI [10.1007/978-3-642-36359-7_17, DOI 10.1007/978-3-642-36359-7_17]
  • [9] Cell refractive index tomography by digital holographic microscopy
    Charrière, F
    Marian, A
    Montfort, F
    Kuehn, J
    Colomb, T
    Cuche, E
    Marquet, P
    Depeursinge, C
    [J]. OPTICS LETTERS, 2006, 31 (02) : 178 - 180
  • [10] Extended depth of focus in tomographic phase microscopy using a propagation algorithm
    Choi, Wonshik
    Fang-Yen, Christopher
    Badizadegan, Kamran
    Dasari, Ramachandra R.
    Feld, Michael S.
    [J]. OPTICS LETTERS, 2008, 33 (02) : 171 - 173