Retained Descemet's membrane after penetrating keratoplasty

被引:10
作者
Chen, YP [1 ]
Lai, PCC [1 ]
Chen, PYF [1 ]
Lin, KK [1 ]
Hsiao, CH [1 ]
机构
[1] Chang Gung Mem Hosp, Dept Ophthalmol, Taipei 10591, Taiwan
关键词
D O I
10.1016/S0886-3350(03)00235-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Retained Descemet's membrane is a rare complication of penetrating keratoplasty (PKP). The membrane can become progressively opaque and threaten the health of the corneal graft. We report such a case involving a 53-year-old man. Simultaneous surgical removal of the membrane and phacoemulsification with intraocular lens implantation were performed 3 months after PKP. The graft remained clear and best corrected visual acuity was 20/20 2 years after secondary surgery.
引用
收藏
页码:1842 / 1844
页数:3
相关论文
共 5 条
[1]  
Arenas Archila E, 1993, Refract Corneal Surg, V9, P65
[2]   DISLOCATION OF DESCEMETS MEMBRANE DURING KERATOPLASTY [J].
BROWN, SI ;
DOHLMAN, CH ;
BORUCHOFF, SA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1965, 60 (01) :43-+
[3]   SEPARATION OF DESCEMETS MEMBRANE IN KERATOPLASTY [J].
HENDERSON, JW ;
WOLTER, JR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1968, 65 (03) :375-+
[4]   Neodymium:YAG laser optical opening for retained Descemet's membrane after penetrating keratoplasty [J].
Masket, S ;
Tennen, DG .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (01) :139-141
[5]  