The X-ray detection efficiency of charge coupled devices (CCDs) is dependent on the thickness of the active depletion layer in the silicon, typically less than 40 mu m and limited by the purity of available epitaxial substrates. For X-ray imaging, therefore. The CCD detection efficiency drops sharply above 8 keV. In this Letter, we show that, using a novel illumination geometry, CCDs can detect high energy (up to 100 keV) X-rays with reasonable efficiency and good energy resolution. A novel 2-D imaging hard X-ray detector based on this geometry is discussed.
引用
收藏
页码:298 / 300
页数:3
相关论文
共 10 条
[1]   Silicon detectors for digital radiography [J].
Arfelli, F ;
Barbiellini, G ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
dallaPalma, L ;
diMichiel, M ;
Longo, R ;
Olivo, A ;
Poropat, P ;
Prest, M ;
Rosei, R ;
Savoia, A ;
Sessa, M ;
Tomasini, F ;
Tromba, G ;
Vacchi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :48-53
[2]   SOFT-X-RAY RESPONSE OF CHARGE-COUPLED-DEVICES [J].
CASTELLI, C ;
WELLS, A ;
MCCARTHY, K ;
HOLLAND, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2) :240-243
[3]  
Castelli C M, 1995, J Xray Sci Technol, V5, P207, DOI [10.1016/S0895-3996(05)80004-7, 10.3233/XST-1995-5204]
[4]   SR INSTRUMENTATION FOR OPTIMIZED ANOMALOUS SCATTERING AND HIGH-RESOLUTION STRUCTURE STUDIES OF PROTEINS AND NUCLEIC-ACIDS [J].
DEACON, A ;
HABASH, J ;
HARROP, SJ ;
HELLIWELL, JR ;
HUNTER, WN ;
LEONARD, GA ;
PETERSON, M ;
HADENER, A ;
KALB, AJ ;
ALLINSON, NM ;
CASTELLI, C ;
MOON, K ;
MCSWEENEY, S ;
GONZALEZ, A ;
THOMPSON, AW ;
EALICK, S ;
SZEBENYI, DM ;
WALTER, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1287-1292
[5]   X-RAY FOCUSING USING SQUARE-PORE MICROCHANNEL PLATES - 1ST OBSERVATION OF CRUXIFORM IMAGE STRUCTURE [J].
FRASER, GW ;
BRUNTON, AN ;
LEES, JE ;
PEARSON, JF ;
FELLER, WB .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 324 (1-2) :404-407
[6]   LARGE, HIGH-RESOLUTION CDTE GAMMA-RAY SENSORS [J].
HAZLETT, T ;
COLE, H ;
SQUILLANTE, MR ;
ENTINE, G ;
SUGARS, G ;
FECYCH, W ;
TENCH, O .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) :332-335
[7]  
HOLLAND AD, 1989, P SOC PHOTO-OPT INS, V1159, P113
[8]   X-RAY-DETECTION USING BULK GAAS [J].
HOLLAND, AD ;
SHORT, ADT ;
CROSS, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 346 (1-2) :366-371
[9]   Hard X-ray beam detector based on microchannel plates [J].
Shikhaliev, PM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (01) :147-150
[10]  
WELLS A, 1991, P SPIE, V1549