Experimental analysis of the thermal entrainment factor of air curtains in vertical open display cabinets for different ambient air conditions

被引:64
作者
Gaspar, Pedro Dinis [1 ]
Carrilho Goncalves, L. C. [1 ]
Pitarma, R. A. [2 ]
机构
[1] Univ Beira Interior, Electromech Engn Dept, P-6201001 Cavilha, Portugal
[2] Polytech Inst Guarda, High Sch Technol & Management, Dept Mech Engn, P-6300559 Guarda, Portugal
关键词
Thermal entrainment factor; Refrigerated display cabinet; Experimental data; RETAIL DISPLAY; PERFORMANCE; CFD; SIMULATION;
D O I
10.1016/j.applthermaleng.2010.11.020
中图分类号
O414.1 [热力学];
学科分类号
摘要
The vertical open refrigerated display cabinets suffer alterations of their thermal performance and energy efficiency due to variations of ambient air conditions. The air curtain provides an aerothermodynamics insulation effect that can be evaluated by the thermal entrainment factor calculation as an engineering approximation or by the calculus of all sensible and latent thermal loads. This study presents the variation of heat transfer rate and thermal entrainment factor obtained through experimental tests carried out for different ambient air conditions, varying air temperature, relative humidity, velocity and its direction relatively to the display cabinet frontal opening. The thermal entrainment factor are analysed and compared with the total sensible and latent heats results for the experimental tests. From an engineering point of view, it is concluded that thermal entrainment factor cannot be used indiscriminately, although its use is suitable to design better cabinet under the same climate class condition. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:961 / 969
页数:9
相关论文
共 26 条
[1]  
Axell M., 2003, P 21 INT C REFR WASH
[2]  
Billard F., 2002, Final Report prepared for UNEP - United Nations Environment Programme
[3]   Experimental study of the performance of single-band air curtains for a multi-deck refrigerated display cabinet [J].
Chen, YG ;
Yuan, XL .
JOURNAL OF FOOD ENGINEERING, 2005, 69 (03) :261-267
[4]   Parametric evaluation of refrigerated air curtains for thermal insulation [J].
Chen, Yun-Guang .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (10) :1988-1996
[5]   CFD simulation of refrigerated display cabinets [J].
Cortella, G ;
Manzan, M ;
Comini, G .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (03) :250-260
[6]   Two- and three-dimensional CFD applied to vertical display cabinets simulation [J].
D'Agaro, P ;
Cortella, G ;
Croce, G .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (02) :178-190
[7]  
*EN ISO, 2005, 23953 ENISO 2
[8]  
*EN ISO, 2005, 23953 ENISO 1
[9]   Temperature and energy performance of refrigerated retail display and commercial catering cabinets under test conditions [J].
Evans, J. A. ;
Scarcelli, S. ;
Swain, M. V. L. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (03) :398-408
[10]  
Faramarzi R, 1999, ASHRAE J, V41, P46