Maintenance cycle extension in the IRIS advanced light water reactor plant design

被引:7
作者
Galvin, MR
Todreas, NE
Conway, LE
机构
[1] USN, Sunnyvale, CA 94088 USA
[2] MIT, Dept Nucl Engn, Cambridge, MA 02139 USA
[3] Westinghouse Sci & Technol Ctr, Pittsburgh, PA 15235 USA
关键词
operating cycle; IRIS; surveillance;
D O I
10.13182/NT03-A3416
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
New nuclear power generation in the United States will be realized only if the economic performance can be made competitive with other methods of electrical power generation. The economic performance of a nuclear power plant can be significantly improved by increasing the time spent on-line generating electricity relative to the time spent off-line conducting maintenance and refueling. Maintenance includes planned actions (surveillances) and unplanned actions (corrective maintenance) to respond to component degradation or failure. A methodology is described that can be used to resolve, in the design phase, maintenance-related operating cycle length barriers. A primary goal was to demonstrate the applicability and utility of the methodology in the context Of the International Reactor, Innovative and Secure (IRIS) design. IRIS is an advanced light water nuclear power plant that is being designed to maximize this on-line generating time by increasing the operating cycle length. This is consequently a maintenance strategy paper using the IRIS plant as the example. Potential IRIS operating cycle length maintenance-related barriers, determined by modification of an earlier operating pressurized water reactor (PWR) plant cycle length analysis to account for differences between the design of IRIS and this operating PWR, are presented. The proposed methodology to resolve these maintenance-related barriers by the design process is described. The results of applying the methodology to two potential IRIS cycle length barriers, relief valve testing and emergency heat removal system testing, are presented.
引用
收藏
页码:270 / 280
页数:11
相关论文
共 6 条
[1]  
American Society of Mechanical Engineers, 2001, BOIL PRESS VESS COD
[2]  
*ASME, ISTC5240 ASME
[3]  
CARELLI MD, 2001, P INT M BACK END FUE
[4]  
CARELLI MD, IAEA INT SEM STAT PR
[5]  
GALVIN MR, 2001, THESIS MIT
[6]  
MCHENRY RS, 1997, P 5 INT TOPL M NUCL