Local heat/mass transfer measurements in a rectangular duct with discrete ribs

被引:73
作者
Cho, HH [1 ]
Wu, SJ [1 ]
Kwon, HJ [1 ]
机构
[1] Yonsei Univ, Dept Mech Engn, Seoul 120749, South Korea
来源
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME | 2000年 / 122卷 / 03期
关键词
D O I
10.1115/1.1303049
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The influence of arrangement and length of discrete ribs on heat/mass transfer and friction loss is investigated. Mass transfer experiments are conducted to obtain the detailed local hear/mass transfer information on the ribbed wall. The aspect ratio (width/height) of the duct is 2.04 and the rib height is one tenth of the duct height, such that the ratio of the rib height to hydraulic diameter is 0.0743. The ratio of rib to-rib distance to rib height is 10. The discrete ribs were made by dividing each continuous rib into two, three, or five pieces, which were attached periodically to the top and bottom walls of the duct with a parallel orientation. The combined effects of rib angle and length of the discrete ribs on heat/mass transfer are considered for the rib angles (alpha) of 90 and 45 deg. As the number of the discrete ribs increases, the uniformity of the heat/mass transfer distributions increases. For alpha =90 deg, the heat/mass transfer enhancement with the discrete ribs is remarkable, while the heat/mass transfer performances are slightly higher than that of the transverse continuous ribs due to the accompanied high friction loss penalty. For ct = 45 deg, the average heat/mass transfer coefficients and the heat/mass transfer performances decrease slightly with the discrete ribs compared to the case of the angled continuous ribs. [S0889-504X(00)00103-3].
引用
收藏
页码:579 / 586
页数:8
相关论文
共 29 条
[1]   Developing and periodically developed flow, temperature and heat transfer in a ribbed duct [J].
Acharya, S ;
Myrum, T ;
Qiu, X ;
Sinha, S .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (02) :461-479
[2]   VAPOR-PRESSURE OF NAPHTHALENE [J].
AMBROSE, D ;
LAWRENSON, IJ ;
SPRAKE, CHS .
JOURNAL OF CHEMICAL THERMODYNAMICS, 1975, 7 (12) :1173-1176
[3]  
CHANDRA PR, 1988, ASME, V110, P233
[4]  
CHO HH, 1998, P 11 INT S TRANSP PH, P364
[5]  
Chyu MK, 1989, EXP HEAT TRANSFER, V2, P291
[6]  
CHYU MK, 1989, ASME HTD, V30, P25
[7]   Detailed heat transfer distributions in two-pass square channels with rib turbulators [J].
Ekkad, SV ;
Han, JC .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (11) :2525-2537
[8]   A REVIEW OF MASS-TRANSFER MEASUREMENTS USING NAPHTHALENE SUBLIMATION [J].
GOLDSTEIN, RJ ;
CHO, HH .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1995, 10 (04) :416-434
[9]   DEVELOPING HEAT-TRANSFER IN RECTANGULAR CHANNELS WITH RIB TURBULATORS [J].
HAN, JC ;
PARK, JS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (01) :183-195
[10]   HIGH-PERFORMANCE HEAT-TRANSFER DUCTS WITH PARALLEL BROKEN AND V-SHAPED BROKEN RIBS [J].
HAN, JC ;
ZHANG, YM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (02) :513-523