Fit-free analysis of fluorescence lifetime imaging data using the phasor approach

被引:212
作者
Ranjit, Suman [1 ]
Malacrida, Leonel [1 ,2 ]
Jameson, David M. [3 ]
Grafton, Enrico [1 ]
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Lab Fluorescence Dynam, Irvine, CA 92697 USA
[2] Univ Republica, Hosp Clin, Dept Fisiopatol, Montevideo, Uruguay
[3] Univ Hawaii Manoa, Dept Cell & Mol Biol, Honolulu, HI 96822 USA
关键词
TIME-RESOLVED FLUORESCENCE; MITOCHONDRIAL NADH; IN-VIVO; CELLS; MICROSCOPY; STATES; STANDARDS; DYNAMICS; COENZYME; SYSTEM;
D O I
10.1038/s41596-018-0026-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence lifetime imaging microscopy (FLIM) is used in diverse disciplines, including biology, chemistry and biophysics, but its use has been limited by the complexity of the data analysis. The phasor approach to FLIM has the potential to markedly reduce this complexity and at the same time provide a powerful visualization of the data content. Phasor plots for fluorescence lifetime analysis were originally developed as a graphical representation of excited-state fluorescence lifetimes for in vitro systems. The method's simple mathematics and specific rules avoid errors and confusion common in the study of complex and heterogeneous fluorescence. In the case of FLIM, the phasor approach has become a powerful method for simple and fit-free analyses of the information contained in the many thousands of pixels constituting an image. At present, the phasor plot is used not only for FLIM, but also for hyperspectral imaging, wherein phasors provide an unprecedented understanding of heterogeneous fluorescence. Undoubtedly, phasor plots will be increasingly important in the future analysis and understanding of FLIM and hyperspectral confocal imaging. This protocol presents the principle of the method and guides users through one of the popular interfaces for FLIM phasor analysis, namely, the SimFCS software. Implementation of the analysis takes only minutes to complete for a dataset containing hundreds of files.
引用
收藏
页码:1979 / 2004
页数:26
相关论文
共 54 条
  • [11] A novel fluorescence lifetime imaging system that optimizes photon efficiency
    Colyer, Ryan A.
    Lee, Claudia
    Gratton, Enrico
    [J]. MICROSCOPY RESEARCH AND TECHNIQUE, 2008, 71 (03) : 201 - 213
  • [12] Label-free imaging of metabolism and oxidative stress in human induced pluripotent stem cell-derived cardiomyocytes
    Datta, Rupsa
    Heylman, Christopher
    George, Steven C.
    Gratton, Enrico
    [J]. BIOMEDICAL OPTICS EXPRESS, 2016, 7 (05): : 1690 - 1701
  • [13] Fluorescence lifetime imaging of endogenous biomarker of oxidative stress
    Datta, Rupsa
    Alfonso-Garcia, Alba
    Cinco, Rachel
    Gratton, Enrico
    [J]. SCIENTIFIC REPORTS, 2015, 5
  • [14] A simple approach for measuring FRET in fluorescent biosensors using two-photon microscopy
    Day, Richard N.
    Tao, Wen
    Dunn, Kenneth W.
    [J]. NATURE PROTOCOLS, 2016, 11 (11) : 21 - 35
  • [15] Digman M., 2014, FLUORESCENCE LIFETIM, P235, DOI DOI 10.1201/B17018-14
  • [16] The phasor approach to fluorescence lifetime imaging analysis
    Digman, Michelle A.
    Caiolfa, Valeria R.
    Zamai, Moreno
    Gratton, Enrico
    [J]. BIOPHYSICAL JOURNAL, 2008, 94 (02) : L14 - L16
  • [17] Fluorescent protein-based biosensors: resolving spatiotemporal dynamics of signaling
    DiPilato, Lisa M.
    Zhang, Jin
    [J]. CURRENT OPINION IN CHEMICAL BIOLOGY, 2010, 14 (01) : 37 - 42
  • [18] Gratton E., 2016, PERSPECTIVES FLUORES, P67
  • [19] Nucleobase-Specific Enhancement of Cy3 Fluorescence
    Harvey, Billie J.
    Levitus, Marcia
    [J]. JOURNAL OF FLUORESCENCE, 2009, 19 (03) : 443 - 448
  • [20] Millisecond spatiotemporal dynamics of FRET biosensors by the pair correlation function and the phasor approach to FLIM
    Hinde, Elizabeth
    Digman, Michelle A.
    Hahn, Klaus M.
    Gratton, Enrico
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (01) : 135 - 140