Fault-tolerant optimal pitch control of wind turbines using dynamic weighted parallel firefly algorithm

被引:23
作者
Mousavi, Yashar [1 ]
Bevan, Geraint [1 ]
Kucukdemiral, Ibrahim Beklan [1 ]
机构
[1] Glasgow Caledonian Univ, Dept Appl Sci, Sch Comp Engn & Built Environm, Glasgow G4 0BA, Lanark, Scotland
关键词
Fault-tolerant control; Wind turbine; Pitch control; Optimization; Firefly algorithm; Fractional calculus; WHALE OPTIMIZATION ALGORITHM; ACTIVE POWER-CONTROL; PI CONTROL; MODEL; SPEED; DESIGN; PERFORMANCE; SYSTEM;
D O I
10.1016/j.isatra.2021.10.019
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
With steadily increasing interest in utilizing wind turbine (WT) systems as primary electrical energy generators, fault-tolerance has been considered decisive to enhance their efficiency and reliability. In this work, an optimal fault-tolerant pitch control (FTPC) strategy is addressed to adjust the pitch angle of WT blades in the presence of sensor, actuator, and system faults. The proposed scheme incorporates a fractional-calculus based extended memory (EM) of pitch angles along with a fractional-order proportional-integral-derivative (FOPID) controller to enhance the performance of the WT. A dynamic weighted parallel firefly algorithm (DWPFA) is also proposed to tune the controller parameters. The efficiency of the proposed algorithm is evaluated on the test functions adopted from 2017 IEEE congress on evolutionary computation (CEC2017). The merits of the proposed fault-tolerant approach are tested on a 4.8-MW WT benchmark model and compared to conventional PI and optimal FOPID approaches. Corresponding comparative simulation results validate the effectiveness and fault-tolerant capability of the proposed control paradigm, where it is observed that the proposed control scheme tends to be more consistent in the power generated at a given wind speed. (C) 2021 ISA. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:301 / 317
页数:17
相关论文
共 64 条
  • [1] Maximum power extraction from wind energy system using homotopy singular perturbation and fast terminal sliding mode method
    Abolvafaei, Mahnaz
    Ganjefar, Soheil
    [J]. RENEWABLE ENERGY, 2020, 148 : 611 - 626
  • [2] A Fuzzy-PI control to extract an optimal power from wind turbine
    Aissaoui, Abdel Ghani
    Tahour, Ahmed
    Essounbouli, Najib
    Nollet, Frederic
    Abid, Mohamed
    Chergui, Moulay Idriss
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 65 : 688 - 696
  • [3] An improved hybrid firefly algorithm for capacitated vehicle routing problem
    Altabeeb, Asma M.
    Mohsen, Abdulqader M.
    Ghallab, Abdullatif
    [J]. APPLIED SOFT COMPUTING, 2019, 84
  • [4] Closed-loop step response for tuning PID-fractional-order-filter controllers
    Amoura, Karima
    Mansouri, Rachid
    Bettayeb, Maamar
    Al-Saggaf, Ubaid M.
    [J]. ISA TRANSACTIONS, 2016, 64 : 247 - 257
  • [5] Fractional order PID for tracking control of a parallel robotic manipulator type delta
    Angel, L.
    Viola, J.
    [J]. ISA TRANSACTIONS, 2018, 79 : 172 - 188
  • [6] Load mitigation of a class of 5-MW wind turbine with RBF neural network based fractional-order PID controller
    Asgharnia, A.
    Jamali, A.
    Shahnazi, R.
    Maheri, A.
    [J]. ISA TRANSACTIONS, 2020, 96 : 272 - 286
  • [7] Performance and robustness of optimal fractional fuzzy PID controllers for pitch control of a wind turbine using chaotic optimization algorithms
    Asgharnia, Amirhossein
    Shahnazi, Reza
    Jamali, Ali
    [J]. ISA TRANSACTIONS, 2018, 79 : 27 - 44
  • [8] Awad NH, 2017, IEEE C EVOL COMPUTAT, P372, DOI 10.1109/CEC.2017.7969336
  • [9] Analytical design of fractional order PID controllers based on the fractional set-point weighted structure: Case study in twin rotor helicopter
    Azarmi, Roohallah
    Tavakoli-Kakhki, Mahsan
    Sedigh, Ali Khaki
    Fatehi, Alireza
    [J]. MECHATRONICS, 2015, 31 : 222 - 233
  • [10] Fault tolerant control of wind turbines with an adaptive output feedback sliding mode controller
    Azizi, Askar
    Nourisola, Hamid
    Shoja-Majidabad, Sajjad
    [J]. RENEWABLE ENERGY, 2019, 135 : 55 - 65